The development of a technique for the determination of disolved chromium(III) and total dissolved chromium in seawater by electron capture detection gas chromatography

A gas chromatographic method for the determination of dissolved Cr(III) and total dissolved Cr in seawater was developed. The technique uses the electron capture detection of the 1,1,1-trifluoro-2,4-pentanedione (Htfa) derivative of Cr(III), Cr(tfa)₃, which was prepared from solvent extraction of a...

Full description

Bibliographic Details
Main Author: Mugo, Robert K.
Language:English
Published: University of British Columbia 2010
Online Access:http://hdl.handle.net/2429/30137
id ndltd-UBC-oai-circle.library.ubc.ca-2429-30137
record_format oai_dc
spelling ndltd-UBC-oai-circle.library.ubc.ca-2429-301372018-01-05T17:45:27Z The development of a technique for the determination of disolved chromium(III) and total dissolved chromium in seawater by electron capture detection gas chromatography Mugo, Robert K. A gas chromatographic method for the determination of dissolved Cr(III) and total dissolved Cr in seawater was developed. The technique uses the electron capture detection of the 1,1,1-trifluoro-2,4-pentanedione (Htfa) derivative of Cr(III), Cr(tfa)₃, which was prepared from solvent extraction of a 15-mL seawater sample. The method was applied to stored acidified samples for the determination of total Cr and to stored, frozen, unacidified samples for the determination of Cr(III) and, after reduction, total Cr (with Cr(VI) being obtained as the difference of these two). The accuracy of the technique was assessed by the analysis of standard reference materials from the National Research Council of Canada. The Cr values obtained for the reference materials using this method were in good agreement with the certified values. The technique has a precision of 1.3% at 4.67 nM with detection limits (3 σn-₁) for Cr(III) and total Cr of 0.186 and 0.243 nM in the original seawater, respectively. The method is designed to be applied to the determination of Cr in seawater samples immediately after collection onboard ship during oceanographic cruises. The attempt to extend the technique to the determination of gallium in seawater was not successful due to thermal instability and/or insufficient volatility of the Ga(tfa)₃ chelate. Science, Faculty of Chemistry, Department of Graduate 2010-11-25T00:38:21Z 2010-11-25T00:38:21Z 1991 Text Thesis/Dissertation http://hdl.handle.net/2429/30137 eng For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use. University of British Columbia
collection NDLTD
language English
sources NDLTD
description A gas chromatographic method for the determination of dissolved Cr(III) and total dissolved Cr in seawater was developed. The technique uses the electron capture detection of the 1,1,1-trifluoro-2,4-pentanedione (Htfa) derivative of Cr(III), Cr(tfa)₃, which was prepared from solvent extraction of a 15-mL seawater sample. The method was applied to stored acidified samples for the determination of total Cr and to stored, frozen, unacidified samples for the determination of Cr(III) and, after reduction, total Cr (with Cr(VI) being obtained as the difference of these two). The accuracy of the technique was assessed by the analysis of standard reference materials from the National Research Council of Canada. The Cr values obtained for the reference materials using this method were in good agreement with the certified values. The technique has a precision of 1.3% at 4.67 nM with detection limits (3 σn-₁) for Cr(III) and total Cr of 0.186 and 0.243 nM in the original seawater, respectively. The method is designed to be applied to the determination of Cr in seawater samples immediately after collection onboard ship during oceanographic cruises. The attempt to extend the technique to the determination of gallium in seawater was not successful due to thermal instability and/or insufficient volatility of the Ga(tfa)₃ chelate. === Science, Faculty of === Chemistry, Department of === Graduate
author Mugo, Robert K.
spellingShingle Mugo, Robert K.
The development of a technique for the determination of disolved chromium(III) and total dissolved chromium in seawater by electron capture detection gas chromatography
author_facet Mugo, Robert K.
author_sort Mugo, Robert K.
title The development of a technique for the determination of disolved chromium(III) and total dissolved chromium in seawater by electron capture detection gas chromatography
title_short The development of a technique for the determination of disolved chromium(III) and total dissolved chromium in seawater by electron capture detection gas chromatography
title_full The development of a technique for the determination of disolved chromium(III) and total dissolved chromium in seawater by electron capture detection gas chromatography
title_fullStr The development of a technique for the determination of disolved chromium(III) and total dissolved chromium in seawater by electron capture detection gas chromatography
title_full_unstemmed The development of a technique for the determination of disolved chromium(III) and total dissolved chromium in seawater by electron capture detection gas chromatography
title_sort development of a technique for the determination of disolved chromium(iii) and total dissolved chromium in seawater by electron capture detection gas chromatography
publisher University of British Columbia
publishDate 2010
url http://hdl.handle.net/2429/30137
work_keys_str_mv AT mugorobertk thedevelopmentofatechniqueforthedeterminationofdisolvedchromiumiiiandtotaldissolvedchromiuminseawaterbyelectroncapturedetectiongaschromatography
AT mugorobertk developmentofatechniqueforthedeterminationofdisolvedchromiumiiiandtotaldissolvedchromiuminseawaterbyelectroncapturedetectiongaschromatography
_version_ 1718594066442092544