The electrical breakdown characteristics of oil/paper insulation under fast front impulse voltages

Gas Insulated Substation (GIS) and Gas Insulated Transmission Line (GITL) have found broad application in power system over the last twenty years. Disconnect switch operations in this equipment causes transient voltages with rise times as fast as 5 to 20 nanoseconds and magnitudes as high as 2.5 pu....

Full description

Bibliographic Details
Main Author: Wang, Mengguang
Language:English
Published: University of British Columbia 2010
Online Access:http://hdl.handle.net/2429/30108
id ndltd-UBC-oai-circle.library.ubc.ca-2429-30108
record_format oai_dc
spelling ndltd-UBC-oai-circle.library.ubc.ca-2429-301082018-01-05T17:45:27Z The electrical breakdown characteristics of oil/paper insulation under fast front impulse voltages Wang, Mengguang Gas Insulated Substation (GIS) and Gas Insulated Transmission Line (GITL) have found broad application in power system over the last twenty years. Disconnect switch operations in this equipment causes transient voltages with rise times as fast as 5 to 20 nanoseconds and magnitudes as high as 2.5 pu. There is very little information on the effect of these transients on oil/paper insulated equipment connected to the GIS and GITL. There have been reports of transformer and bushing failures which may have been caused by these transients. In the investigation reported in this thesis, the electrical breakdown properties of oil/paper insulation under fast front impulse were studied. A test system was built to generate a high voltage fast front (rise time less than 10 ns) and to apply this voltage to oil/paper samples. The breakdown characteristics of oil/paper insulation was investigated using different types of paper, types of oil and number of layers of paper. Insulation breakdown voltage vs breakdown time (V-t) data was obtained with the fast front step waveform and V₅₀ breakdown data was obtained with the fast front waveform and lightning and switching impulse waveforms. The V-t data was analyzed using the histogram, Weibull distribution and equal area criterion methods. A 2% probability V-t curve was generated and fits the data well. The V₅₀ test results showed that the fast front impulse waveform has the lowest breakdown voltage and the switching impulse has the highest breakdown value. Applied Science, Faculty of Electrical and Computer Engineering, Department of Graduate 2010-11-23T17:00:08Z 2010-11-23T17:00:08Z 1991 Text Thesis/Dissertation http://hdl.handle.net/2429/30108 eng For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use. University of British Columbia
collection NDLTD
language English
sources NDLTD
description Gas Insulated Substation (GIS) and Gas Insulated Transmission Line (GITL) have found broad application in power system over the last twenty years. Disconnect switch operations in this equipment causes transient voltages with rise times as fast as 5 to 20 nanoseconds and magnitudes as high as 2.5 pu. There is very little information on the effect of these transients on oil/paper insulated equipment connected to the GIS and GITL. There have been reports of transformer and bushing failures which may have been caused by these transients. In the investigation reported in this thesis, the electrical breakdown properties of oil/paper insulation under fast front impulse were studied. A test system was built to generate a high voltage fast front (rise time less than 10 ns) and to apply this voltage to oil/paper samples. The breakdown characteristics of oil/paper insulation was investigated using different types of paper, types of oil and number of layers of paper. Insulation breakdown voltage vs breakdown time (V-t) data was obtained with the fast front step waveform and V₅₀ breakdown data was obtained with the fast front waveform and lightning and switching impulse waveforms. The V-t data was analyzed using the histogram, Weibull distribution and equal area criterion methods. A 2% probability V-t curve was generated and fits the data well. The V₅₀ test results showed that the fast front impulse waveform has the lowest breakdown voltage and the switching impulse has the highest breakdown value. === Applied Science, Faculty of === Electrical and Computer Engineering, Department of === Graduate
author Wang, Mengguang
spellingShingle Wang, Mengguang
The electrical breakdown characteristics of oil/paper insulation under fast front impulse voltages
author_facet Wang, Mengguang
author_sort Wang, Mengguang
title The electrical breakdown characteristics of oil/paper insulation under fast front impulse voltages
title_short The electrical breakdown characteristics of oil/paper insulation under fast front impulse voltages
title_full The electrical breakdown characteristics of oil/paper insulation under fast front impulse voltages
title_fullStr The electrical breakdown characteristics of oil/paper insulation under fast front impulse voltages
title_full_unstemmed The electrical breakdown characteristics of oil/paper insulation under fast front impulse voltages
title_sort electrical breakdown characteristics of oil/paper insulation under fast front impulse voltages
publisher University of British Columbia
publishDate 2010
url http://hdl.handle.net/2429/30108
work_keys_str_mv AT wangmengguang theelectricalbreakdowncharacteristicsofoilpaperinsulationunderfastfrontimpulsevoltages
AT wangmengguang electricalbreakdowncharacteristicsofoilpaperinsulationunderfastfrontimpulsevoltages
_version_ 1718594058982522880