A polarimeter for spin transfer measurements of the [pi]d[right arrow]pp reaction

A proton polarimeter has been constructed at TRIUMF, with design specifications intended to measure the polarization of protons over an energy range of 100 MeV to 300 MeV. It was built as the principle detector in an experiment to determine three spin-transfer parameters of the fundamental π⃗d → p⃗p...

Full description

Bibliographic Details
Main Author: Feltham, Andrew G.
Language:English
Published: University of British Columbia 2010
Subjects:
Online Access:http://hdl.handle.net/2429/27878
id ndltd-UBC-oai-circle.library.ubc.ca-2429-27878
record_format oai_dc
spelling ndltd-UBC-oai-circle.library.ubc.ca-2429-278782018-01-05T17:44:20Z A polarimeter for spin transfer measurements of the [pi]d[right arrow]pp reaction Feltham, Andrew G. TRIUMF Pions Spin exchange A proton polarimeter has been constructed at TRIUMF, with design specifications intended to measure the polarization of protons over an energy range of 100 MeV to 300 MeV. It was built as the principle detector in an experiment to determine three spin-transfer parameters of the fundamental π⃗d → p⃗p reaction. In this thesis, some theoretical and experimental design aspects of the spin-transfer measurement are discussed. The intent of this thesis is to describe an experiment¹ which measures the polarization of protons emitted from the πd→ p⃗p reaction, using an unpolarized target². The sole purpose of this experiment is to demonstrate that our polarimeter and general apparatus are capable of identifying the πd → pp events from a large background presence, and that the systematic errors associated with the polarization extraction have been identified. To this extent, the system is ready to produce the proton polarization required for the spin-transfer measurements. ¹This experiment is identical in all respects to the spin-transfer experiment, except that here, the target is unpolarized. ²The polarization of the protons is well know from the analyzing power, An₀, of the time reversed p⃗p → dπ reaction. Science, Faculty of Physics and Astronomy, Department of Graduate 2010-08-28T17:13:38Z 2010-08-28T17:13:38Z 1988 Text Thesis/Dissertation http://hdl.handle.net/2429/27878 eng For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use. University of British Columbia
collection NDLTD
language English
sources NDLTD
topic TRIUMF
Pions
Spin exchange
spellingShingle TRIUMF
Pions
Spin exchange
Feltham, Andrew G.
A polarimeter for spin transfer measurements of the [pi]d[right arrow]pp reaction
description A proton polarimeter has been constructed at TRIUMF, with design specifications intended to measure the polarization of protons over an energy range of 100 MeV to 300 MeV. It was built as the principle detector in an experiment to determine three spin-transfer parameters of the fundamental π⃗d → p⃗p reaction. In this thesis, some theoretical and experimental design aspects of the spin-transfer measurement are discussed. The intent of this thesis is to describe an experiment¹ which measures the polarization of protons emitted from the πd→ p⃗p reaction, using an unpolarized target². The sole purpose of this experiment is to demonstrate that our polarimeter and general apparatus are capable of identifying the πd → pp events from a large background presence, and that the systematic errors associated with the polarization extraction have been identified. To this extent, the system is ready to produce the proton polarization required for the spin-transfer measurements. ¹This experiment is identical in all respects to the spin-transfer experiment, except that here, the target is unpolarized. ²The polarization of the protons is well know from the analyzing power, An₀, of the time reversed p⃗p → dπ reaction. === Science, Faculty of === Physics and Astronomy, Department of === Graduate
author Feltham, Andrew G.
author_facet Feltham, Andrew G.
author_sort Feltham, Andrew G.
title A polarimeter for spin transfer measurements of the [pi]d[right arrow]pp reaction
title_short A polarimeter for spin transfer measurements of the [pi]d[right arrow]pp reaction
title_full A polarimeter for spin transfer measurements of the [pi]d[right arrow]pp reaction
title_fullStr A polarimeter for spin transfer measurements of the [pi]d[right arrow]pp reaction
title_full_unstemmed A polarimeter for spin transfer measurements of the [pi]d[right arrow]pp reaction
title_sort polarimeter for spin transfer measurements of the [pi]d[right arrow]pp reaction
publisher University of British Columbia
publishDate 2010
url http://hdl.handle.net/2429/27878
work_keys_str_mv AT felthamandrewg apolarimeterforspintransfermeasurementsofthepidrightarrowppreaction
AT felthamandrewg polarimeterforspintransfermeasurementsofthepidrightarrowppreaction
_version_ 1718593481984704512