A saturation calibration of Hamamatsu’s multi-pixel photon counter
A relative calibration of the Fine-Grained Detector (FGD) in the T2K experiment is presented, with emphasis on the saturation calibration effects in Hamamatsu's multi-pixel photon counters (MPPCs). The calibration is produced on a test bed with a Hamamatsu Pico-Second Pulsed laser, on a small m...
Main Author: | |
---|---|
Language: | English |
Published: |
University of British Columbia
2010
|
Online Access: | http://hdl.handle.net/2429/27793 |
id |
ndltd-UBC-oai-circle.library.ubc.ca-2429-27793 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-UBC-oai-circle.library.ubc.ca-2429-277932018-01-05T17:24:32Z A saturation calibration of Hamamatsu’s multi-pixel photon counter Hastings, Simon Philip A relative calibration of the Fine-Grained Detector (FGD) in the T2K experiment is presented, with emphasis on the saturation calibration effects in Hamamatsu's multi-pixel photon counters (MPPCs). The calibration is produced on a test bed with a Hamamatsu Pico-Second Pulsed laser, on a small model of the FGD on a sample of fibers and MPPCs. The wavelength shifting fiber-MPPC complex used in the FGD is found to have an effective pixel count of 518, and to exhibit an effective after-pulsing and crosstalk fraction of 1.6% when measured between 0.6 and 0.9 Volts over-voltage (V OV). Science, Faculty of Physics and Astronomy, Department of Graduate 2010-08-25T20:31:32Z 2010-08-25T20:31:32Z 2010 2010-11 Text Thesis/Dissertation http://hdl.handle.net/2429/27793 eng Attribution-NonCommercial-NoDerivatives 4.0 International http://creativecommons.org/licenses/by-nc-nd/4.0/ University of British Columbia |
collection |
NDLTD |
language |
English |
sources |
NDLTD |
description |
A relative calibration of the Fine-Grained Detector (FGD) in the T2K experiment is presented, with emphasis on the saturation calibration effects in Hamamatsu's multi-pixel photon counters (MPPCs). The calibration is produced on a test bed with a Hamamatsu Pico-Second Pulsed laser, on a small model of the FGD on a sample of fibers and MPPCs. The wavelength shifting fiber-MPPC complex used in the FGD is found to have an effective pixel count of 518, and to exhibit an effective after-pulsing and crosstalk fraction of 1.6% when measured between 0.6 and 0.9 Volts over-voltage (V OV). === Science, Faculty of === Physics and Astronomy, Department of === Graduate |
author |
Hastings, Simon Philip |
spellingShingle |
Hastings, Simon Philip A saturation calibration of Hamamatsu’s multi-pixel photon counter |
author_facet |
Hastings, Simon Philip |
author_sort |
Hastings, Simon Philip |
title |
A saturation calibration of Hamamatsu’s multi-pixel photon counter |
title_short |
A saturation calibration of Hamamatsu’s multi-pixel photon counter |
title_full |
A saturation calibration of Hamamatsu’s multi-pixel photon counter |
title_fullStr |
A saturation calibration of Hamamatsu’s multi-pixel photon counter |
title_full_unstemmed |
A saturation calibration of Hamamatsu’s multi-pixel photon counter |
title_sort |
saturation calibration of hamamatsu’s multi-pixel photon counter |
publisher |
University of British Columbia |
publishDate |
2010 |
url |
http://hdl.handle.net/2429/27793 |
work_keys_str_mv |
AT hastingssimonphilip asaturationcalibrationofhamamatsusmultipixelphotoncounter AT hastingssimonphilip saturationcalibrationofhamamatsusmultipixelphotoncounter |
_version_ |
1718582582549938176 |