Spatially resolved laser induced fluorescence studies in the three electrode direct current plasma

Spectrcchemical emission from analytes in the three electrode direct current plasma has been found to be sensitive to the presence of easily ionizable elements (EIEs) as concomitants in sample matrices. An understanding of the mechanisms by which these EBEs affect analyte emissions is complicated by...

Full description

Bibliographic Details
Main Author: Le Blanc, Charles Wilfred
Language:English
Published: University of British Columbia 2010
Online Access:http://hdl.handle.net/2429/27579
id ndltd-UBC-oai-circle.library.ubc.ca-2429-27579
record_format oai_dc
spelling ndltd-UBC-oai-circle.library.ubc.ca-2429-275792018-01-05T17:44:13Z Spatially resolved laser induced fluorescence studies in the three electrode direct current plasma Le Blanc, Charles Wilfred Spectrcchemical emission from analytes in the three electrode direct current plasma has been found to be sensitive to the presence of easily ionizable elements (EIEs) as concomitants in sample matrices. An understanding of the mechanisms by which these EBEs affect analyte emissions is complicated by the fact that both emission enhancements and suppressions of ion and atom lines have been observed. In order to gain further insight into this effect, a fluorescence spectrometer was built and used as a spatial and spectral probe to obtain analyte population distribution profiles in the plasma. The spatial distribution of the analyte in the plasma was found to be quite complex. Most of the analyte skirted around the plasma core and did not enter the analytical emission zone. The area in the plasma where emission was observed was relatively small compared to the spatial population distribution of the analyte which suggests that the amount of analyte contributing to the emission was a small fraction of the total analyte population present. Three dimensional fluorescence profiles of Ba⁺concentrations in the plasma were determined with and without sodium present as the EIE. The presence of the EIE in the sample did not alter the spatial distribution of the Ba⁺ population significantly but did appear to cause an ionization suppression. Emission profiles of the Ba(I) 553.548 nm and Ba(H) 493.409 nm lines were also obtained with and without an EIE present in the sample matrix. In both cases, the presence of the EIE caused emission enhancements; however, the effect was greater for the Ba(I) line than for the Ba(II) line which supports with the proposed ionization suppression mechanism. Science, Faculty of Chemistry, Department of Graduate 2010-08-21T20:17:33Z 2010-08-21T20:17:33Z 1989 Text Thesis/Dissertation http://hdl.handle.net/2429/27579 eng For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use. University of British Columbia
collection NDLTD
language English
sources NDLTD
description Spectrcchemical emission from analytes in the three electrode direct current plasma has been found to be sensitive to the presence of easily ionizable elements (EIEs) as concomitants in sample matrices. An understanding of the mechanisms by which these EBEs affect analyte emissions is complicated by the fact that both emission enhancements and suppressions of ion and atom lines have been observed. In order to gain further insight into this effect, a fluorescence spectrometer was built and used as a spatial and spectral probe to obtain analyte population distribution profiles in the plasma. The spatial distribution of the analyte in the plasma was found to be quite complex. Most of the analyte skirted around the plasma core and did not enter the analytical emission zone. The area in the plasma where emission was observed was relatively small compared to the spatial population distribution of the analyte which suggests that the amount of analyte contributing to the emission was a small fraction of the total analyte population present. Three dimensional fluorescence profiles of Ba⁺concentrations in the plasma were determined with and without sodium present as the EIE. The presence of the EIE in the sample did not alter the spatial distribution of the Ba⁺ population significantly but did appear to cause an ionization suppression. Emission profiles of the Ba(I) 553.548 nm and Ba(H) 493.409 nm lines were also obtained with and without an EIE present in the sample matrix. In both cases, the presence of the EIE caused emission enhancements; however, the effect was greater for the Ba(I) line than for the Ba(II) line which supports with the proposed ionization suppression mechanism. === Science, Faculty of === Chemistry, Department of === Graduate
author Le Blanc, Charles Wilfred
spellingShingle Le Blanc, Charles Wilfred
Spatially resolved laser induced fluorescence studies in the three electrode direct current plasma
author_facet Le Blanc, Charles Wilfred
author_sort Le Blanc, Charles Wilfred
title Spatially resolved laser induced fluorescence studies in the three electrode direct current plasma
title_short Spatially resolved laser induced fluorescence studies in the three electrode direct current plasma
title_full Spatially resolved laser induced fluorescence studies in the three electrode direct current plasma
title_fullStr Spatially resolved laser induced fluorescence studies in the three electrode direct current plasma
title_full_unstemmed Spatially resolved laser induced fluorescence studies in the three electrode direct current plasma
title_sort spatially resolved laser induced fluorescence studies in the three electrode direct current plasma
publisher University of British Columbia
publishDate 2010
url http://hdl.handle.net/2429/27579
work_keys_str_mv AT leblanccharleswilfred spatiallyresolvedlaserinducedfluorescencestudiesinthethreeelectrodedirectcurrentplasma
_version_ 1718593406324703232