The role of magnetic field gradients in nuclear magnetic resonance

A high resolution NMR probe was modified with gradient coils (31 mm diameter) for the measurement of translational diffusion and for microscopic imaging, and a larger set of gradient coils (15 cm diameter) was constructed for surface coil diffusion measurements. The magnitudes of the gradients produ...

Full description

Bibliographic Details
Main Author: Luck, Stanley David
Language:English
Published: University of British Columbia 2010
Subjects:
Online Access:http://hdl.handle.net/2429/27541
id ndltd-UBC-oai-circle.library.ubc.ca-2429-27541
record_format oai_dc
spelling ndltd-UBC-oai-circle.library.ubc.ca-2429-275412018-01-05T17:44:09Z The role of magnetic field gradients in nuclear magnetic resonance Luck, Stanley David Magnetic resonance imaging A high resolution NMR probe was modified with gradient coils (31 mm diameter) for the measurement of translational diffusion and for microscopic imaging, and a larger set of gradient coils (15 cm diameter) was constructed for surface coil diffusion measurements. The magnitudes of the gradients produced by these coils were determined from the linewidths and lineshapes of gradient spectra. In diffusion experiments using the pulsed gradient method of Stejskal and Tanner, induced eddy currents and slow variation of the magnetic field at the sample interfered with measurements at short echo times. For these experiments the known diffusion coefficient of water was used to determine the effective gradient in each experiment. The diffusion coefficient of acrylonitrile was measured from the decay of single, double and triple quantum echoes using a modified pulsed field gradient spin echo pulse sequence. In the second part of this thesis, three examples of living systems were studied. The first involved the application of pulsed gradient spin echo measurements to characterize the motion of water and lipid, in-vivo, in human forearm. Spin echo spectra from human forearm gave a water signal that was attributed to extracellular water because of relatively long spin-spin relaxation time (0.8 s) compared to that of intracellular water (20-30 ms). Comparison of the diffusivity of water, from experiments at two different echo times suggest that the major part of the motion of water, in-vivo, was due to directionally randomized bulk flow rather than molecular diffusion. The second application involved the chemical shift resolved mapping of the proton distribution, in one-dimension, along the anteroposterior direction, of pupae of the Douglas-fir cone moth Barbara colfaxiana. Proton distribution maps showed that the distribution of the aqueous fluid depended upon the vertical orientation, head pointing upward or downward, of the pupae. Finally, two dimensional images of mature caps of the marine alga Acetabularia mediterranea were obtained using the normal spin echo sequence as well as with T₁, T₂ and diffusion contrasting. D₂O—contrasting was obtained by briefly submerging the caps in D₂O. All of these images showed features resembling the radial structure of the caps. The resolution was estimated by comparison with microscopic views of the caps and was found to be 0.1 mm, determined as the smallest distinguishable feature in the image. Science, Faculty of Chemistry, Department of Graduate 2010-08-20T17:30:38Z 2010-08-20T17:30:38Z 1986 Text Thesis/Dissertation http://hdl.handle.net/2429/27541 eng For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use. University of British Columbia
collection NDLTD
language English
sources NDLTD
topic Magnetic resonance imaging
spellingShingle Magnetic resonance imaging
Luck, Stanley David
The role of magnetic field gradients in nuclear magnetic resonance
description A high resolution NMR probe was modified with gradient coils (31 mm diameter) for the measurement of translational diffusion and for microscopic imaging, and a larger set of gradient coils (15 cm diameter) was constructed for surface coil diffusion measurements. The magnitudes of the gradients produced by these coils were determined from the linewidths and lineshapes of gradient spectra. In diffusion experiments using the pulsed gradient method of Stejskal and Tanner, induced eddy currents and slow variation of the magnetic field at the sample interfered with measurements at short echo times. For these experiments the known diffusion coefficient of water was used to determine the effective gradient in each experiment. The diffusion coefficient of acrylonitrile was measured from the decay of single, double and triple quantum echoes using a modified pulsed field gradient spin echo pulse sequence. In the second part of this thesis, three examples of living systems were studied. The first involved the application of pulsed gradient spin echo measurements to characterize the motion of water and lipid, in-vivo, in human forearm. Spin echo spectra from human forearm gave a water signal that was attributed to extracellular water because of relatively long spin-spin relaxation time (0.8 s) compared to that of intracellular water (20-30 ms). Comparison of the diffusivity of water, from experiments at two different echo times suggest that the major part of the motion of water, in-vivo, was due to directionally randomized bulk flow rather than molecular diffusion. The second application involved the chemical shift resolved mapping of the proton distribution, in one-dimension, along the anteroposterior direction, of pupae of the Douglas-fir cone moth Barbara colfaxiana. Proton distribution maps showed that the distribution of the aqueous fluid depended upon the vertical orientation, head pointing upward or downward, of the pupae. Finally, two dimensional images of mature caps of the marine alga Acetabularia mediterranea were obtained using the normal spin echo sequence as well as with T₁, T₂ and diffusion contrasting. D₂O—contrasting was obtained by briefly submerging the caps in D₂O. All of these images showed features resembling the radial structure of the caps. The resolution was estimated by comparison with microscopic views of the caps and was found to be 0.1 mm, determined as the smallest distinguishable feature in the image. === Science, Faculty of === Chemistry, Department of === Graduate
author Luck, Stanley David
author_facet Luck, Stanley David
author_sort Luck, Stanley David
title The role of magnetic field gradients in nuclear magnetic resonance
title_short The role of magnetic field gradients in nuclear magnetic resonance
title_full The role of magnetic field gradients in nuclear magnetic resonance
title_fullStr The role of magnetic field gradients in nuclear magnetic resonance
title_full_unstemmed The role of magnetic field gradients in nuclear magnetic resonance
title_sort role of magnetic field gradients in nuclear magnetic resonance
publisher University of British Columbia
publishDate 2010
url http://hdl.handle.net/2429/27541
work_keys_str_mv AT luckstanleydavid theroleofmagneticfieldgradientsinnuclearmagneticresonance
AT luckstanleydavid roleofmagneticfieldgradientsinnuclearmagneticresonance
_version_ 1718593395323043840