A preliminary study of the regional groundwater flow in the Meager Mountain geothermal area, British Columbia

The Meager Mountain geothermal area is situated 160 km north-northwest of Vancouver, British Columbia. Various types of existing and field-generated geological and hydro-geological data were employed to fully evaluate the groundwater flow regime of the study site. Mathematical modelling was carried...

Full description

Bibliographic Details
Main Author: Jamieson, Gordon Reginald
Language:English
Published: 2010
Online Access:http://hdl.handle.net/2429/22494
id ndltd-UBC-oai-circle.library.ubc.ca-2429-22494
record_format oai_dc
spelling ndltd-UBC-oai-circle.library.ubc.ca-2429-224942018-01-05T17:41:41Z A preliminary study of the regional groundwater flow in the Meager Mountain geothermal area, British Columbia Jamieson, Gordon Reginald The Meager Mountain geothermal area is situated 160 km north-northwest of Vancouver, British Columbia. Various types of existing and field-generated geological and hydro-geological data were employed to fully evaluate the groundwater flow regime of the study site. Mathematical modelling was carried out to determine the feasible range of regional groundwater flow characteristic in the area. Meager Mountain is a volcano comprised mainly of ande-site and dacite flows, breccias and ash. It became active in the Pliocene, fracturing the Tertiary and older granitic basement rocks through which it erupted. Subsequent alpine glaciation has deposited unconsolidated deposits of variable thickness in the valley bottom. It can be shown that the most likely position for the water table is at an intermediate elevation in the mountain system. Apart from a very few springs at higher elevations, the discharge area is believed to be confined to the portion of the valley covered by unconsolidated deposits. Meager Creek Hotsprings and Pebble Creek Hotsprings are both located in this suggested discharge area near stream level. Water balance calculations for the Lillooet River basin and baseflow determinations in the Meager Creek basin indicate that 14.5 to 17% of the total precipitation enters the groundwater system. Mathematical modelling indicate that the amount of groundwater discharge is dependent on the hydraulic conductivity distribution and water table configuration but independent of the depth of the flow region. The percentage of total precipitation entering the groundwater zone is calculated to be 14-18%, correlating well with the water balance and baseflow calculations. The simulations were used to estimate the hydraulic conductivity of the various materials in the Meager Mountain system. The representative hydraulic conductivities were found to be 10⁻² to 10⁻⁵ m/s for the unconsolidated deposits, 10⁻⁷ to 10⁻⁸ m/s for the basement rock and 10⁻⁴‧⁵ to 10⁻⁸ m/s for the volcanics. The vertical hydraulic conductivity may be as much as 5 times greater than the horizontal in the basement rocks. The horizontal hydraulic conductivity may be as much as 5 times greater than the vertical in the volcanics rocks. Similar vertical hydraulic conductivity values probably exist in the volcanics and in the basement. Recommendations for future work at the Meager Mountain geothermal area include the initiation of a detailed water balance in the south reservoir area, a fracture survey of the volcanic rocks, continued mathematical modelling, and hydraulic conductivity measurements in deep drill holes. Science, Faculty of Earth, Ocean and Atmospheric Sciences, Department of Graduate 2010-03-25T12:58:15Z 2010-03-25T12:58:15Z 1981 Text Thesis/Dissertation http://hdl.handle.net/2429/22494 eng For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use.
collection NDLTD
language English
sources NDLTD
description The Meager Mountain geothermal area is situated 160 km north-northwest of Vancouver, British Columbia. Various types of existing and field-generated geological and hydro-geological data were employed to fully evaluate the groundwater flow regime of the study site. Mathematical modelling was carried out to determine the feasible range of regional groundwater flow characteristic in the area. Meager Mountain is a volcano comprised mainly of ande-site and dacite flows, breccias and ash. It became active in the Pliocene, fracturing the Tertiary and older granitic basement rocks through which it erupted. Subsequent alpine glaciation has deposited unconsolidated deposits of variable thickness in the valley bottom. It can be shown that the most likely position for the water table is at an intermediate elevation in the mountain system. Apart from a very few springs at higher elevations, the discharge area is believed to be confined to the portion of the valley covered by unconsolidated deposits. Meager Creek Hotsprings and Pebble Creek Hotsprings are both located in this suggested discharge area near stream level. Water balance calculations for the Lillooet River basin and baseflow determinations in the Meager Creek basin indicate that 14.5 to 17% of the total precipitation enters the groundwater system. Mathematical modelling indicate that the amount of groundwater discharge is dependent on the hydraulic conductivity distribution and water table configuration but independent of the depth of the flow region. The percentage of total precipitation entering the groundwater zone is calculated to be 14-18%, correlating well with the water balance and baseflow calculations. The simulations were used to estimate the hydraulic conductivity of the various materials in the Meager Mountain system. The representative hydraulic conductivities were found to be 10⁻² to 10⁻⁵ m/s for the unconsolidated deposits, 10⁻⁷ to 10⁻⁸ m/s for the basement rock and 10⁻⁴‧⁵ to 10⁻⁸ m/s for the volcanics. The vertical hydraulic conductivity may be as much as 5 times greater than the horizontal in the basement rocks. The horizontal hydraulic conductivity may be as much as 5 times greater than the vertical in the volcanics rocks. Similar vertical hydraulic conductivity values probably exist in the volcanics and in the basement. Recommendations for future work at the Meager Mountain geothermal area include the initiation of a detailed water balance in the south reservoir area, a fracture survey of the volcanic rocks, continued mathematical modelling, and hydraulic conductivity measurements in deep drill holes. === Science, Faculty of === Earth, Ocean and Atmospheric Sciences, Department of === Graduate
author Jamieson, Gordon Reginald
spellingShingle Jamieson, Gordon Reginald
A preliminary study of the regional groundwater flow in the Meager Mountain geothermal area, British Columbia
author_facet Jamieson, Gordon Reginald
author_sort Jamieson, Gordon Reginald
title A preliminary study of the regional groundwater flow in the Meager Mountain geothermal area, British Columbia
title_short A preliminary study of the regional groundwater flow in the Meager Mountain geothermal area, British Columbia
title_full A preliminary study of the regional groundwater flow in the Meager Mountain geothermal area, British Columbia
title_fullStr A preliminary study of the regional groundwater flow in the Meager Mountain geothermal area, British Columbia
title_full_unstemmed A preliminary study of the regional groundwater flow in the Meager Mountain geothermal area, British Columbia
title_sort preliminary study of the regional groundwater flow in the meager mountain geothermal area, british columbia
publishDate 2010
url http://hdl.handle.net/2429/22494
work_keys_str_mv AT jamiesongordonreginald apreliminarystudyoftheregionalgroundwaterflowinthemeagermountaingeothermalareabritishcolumbia
AT jamiesongordonreginald preliminarystudyoftheregionalgroundwaterflowinthemeagermountaingeothermalareabritishcolumbia
_version_ 1718592032176340992