The calibration of a portable induction magnetometer system

An investigation made concerning the characteristics of a sensor coil for an induction magnetometer shows that it is feasible to make the first stage 60 Hertz rejection filter of the Butterworth type. This is an improvement in design over the Twin-T filter which is sometimes used as a first stage fi...

Full description

Bibliographic Details
Main Author: Zambresky, Liana
Language:English
Published: 2010
Subjects:
Online Access:http://hdl.handle.net/2429/20727
id ndltd-UBC-oai-circle.library.ubc.ca-2429-20727
record_format oai_dc
spelling ndltd-UBC-oai-circle.library.ubc.ca-2429-207272018-01-05T17:40:42Z The calibration of a portable induction magnetometer system Zambresky, Liana Magnetometers An investigation made concerning the characteristics of a sensor coil for an induction magnetometer shows that it is feasible to make the first stage 60 Hertz rejection filter of the Butterworth type. This is an improvement in design over the Twin-T filter which is sometimes used as a first stage filter as the number of electrical components is reduced and there is no possibility of ringing between the coil inductor and the filter capacitors. Two methods of relative calibration for the induction magnetometer system give reliable response curves. One method uses a Wheatstone bridge. The sensor is one arm of the bridge and it is shown that the effect of the signal generator is the same as if the coil was excited by a natural event. The second method involves exciting the sensor by a field created by a small secondary coil. The agreement between the two methods is good. An experimental approach to the absolute calibration is successfully carried out by comparing the output from the uncalibrated system to an air core system which has been previously calibrated. A theoretical approach is used to give a good indication of the sensitivity of the sensor coil. The sensitivity is dependent primarily upon the turn number and the length of the coil. Science, Faculty of Earth, Ocean and Atmospheric Sciences, Department of Graduate 2010-02-22T20:40:01Z 2010-02-22T20:40:01Z 1977 Text Thesis/Dissertation http://hdl.handle.net/2429/20727 eng For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use.
collection NDLTD
language English
sources NDLTD
topic Magnetometers
spellingShingle Magnetometers
Zambresky, Liana
The calibration of a portable induction magnetometer system
description An investigation made concerning the characteristics of a sensor coil for an induction magnetometer shows that it is feasible to make the first stage 60 Hertz rejection filter of the Butterworth type. This is an improvement in design over the Twin-T filter which is sometimes used as a first stage filter as the number of electrical components is reduced and there is no possibility of ringing between the coil inductor and the filter capacitors. Two methods of relative calibration for the induction magnetometer system give reliable response curves. One method uses a Wheatstone bridge. The sensor is one arm of the bridge and it is shown that the effect of the signal generator is the same as if the coil was excited by a natural event. The second method involves exciting the sensor by a field created by a small secondary coil. The agreement between the two methods is good. An experimental approach to the absolute calibration is successfully carried out by comparing the output from the uncalibrated system to an air core system which has been previously calibrated. A theoretical approach is used to give a good indication of the sensitivity of the sensor coil. The sensitivity is dependent primarily upon the turn number and the length of the coil. === Science, Faculty of === Earth, Ocean and Atmospheric Sciences, Department of === Graduate
author Zambresky, Liana
author_facet Zambresky, Liana
author_sort Zambresky, Liana
title The calibration of a portable induction magnetometer system
title_short The calibration of a portable induction magnetometer system
title_full The calibration of a portable induction magnetometer system
title_fullStr The calibration of a portable induction magnetometer system
title_full_unstemmed The calibration of a portable induction magnetometer system
title_sort calibration of a portable induction magnetometer system
publishDate 2010
url http://hdl.handle.net/2429/20727
work_keys_str_mv AT zambreskyliana thecalibrationofaportableinductionmagnetometersystem
AT zambreskyliana calibrationofaportableinductionmagnetometersystem
_version_ 1718591512194842624