High frequency simulation of transformer windings for diagnostic tests

The change in business dynamics, brought on by the deregulation of the electricity industry has had an impact on the technical operations of the companies involved. To maintain competitiveness, industries must maintain a high level of efficiency and reliability. This has led to the shift to condi...

Full description

Bibliographic Details
Main Author: Singh, Arvind
Language:English
Published: 2010
Online Access:http://hdl.handle.net/2429/17550
id ndltd-UBC-oai-circle.library.ubc.ca-2429-17550
record_format oai_dc
spelling ndltd-UBC-oai-circle.library.ubc.ca-2429-175502018-01-05T17:39:00Z High frequency simulation of transformer windings for diagnostic tests Singh, Arvind The change in business dynamics, brought on by the deregulation of the electricity industry has had an impact on the technical operations of the companies involved. To maintain competitiveness, industries must maintain a high level of efficiency and reliability. This has led to the shift to condition monitoring from scheduled maintenance schemes especially for expensive assets which are not immediately replaceable such as power transformers. High current surges impacting power transformers often cause winding deformations. These pose safety risks and heavy financial losses to the utility in spot market buying when failures occur. Long replacement times can have crippling financial effects on a company if there is no replacement for the transformer when a failure occurs. As a result of this diagnostic methods which estimate the transformer condition have become increasingly important. These allow personnel to make decisions on replacing or relocating a power transformer, in keeping with the financial objectives of the company. In this report an overview of the methods used in obtaining winding signatures used for condition monitoring is presented. An equivalent circuit winding model based on multiphase transmission line theory is developed which includes enough detail to allow for an accurate simulation. The circuit model for a specific transformer winding was implemented using Microtran software. The model was used to compare the response of the commonly used transadmittance signature to the characteristic impedance signature of the winding for different types of deformations (simulated by changing different capacitances in the model). It was found that the methods were comparable in sensitivity with the transadmittance being only marginally better. The characteristic impedance signature however had the advantage of showing a constant percentage change over its frequency range for a given distortion. This makes it easier to quantify winding movement. The use of both methods in conjunction may serve as a more efficient method of classifying physical winding changes. Applied Science, Faculty of Electrical and Computer Engineering, Department of Graduate 2010-01-06T00:04:29Z 2010-01-06T00:04:29Z 2006 2006-05 Text Thesis/Dissertation http://hdl.handle.net/2429/17550 eng For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use.
collection NDLTD
language English
sources NDLTD
description The change in business dynamics, brought on by the deregulation of the electricity industry has had an impact on the technical operations of the companies involved. To maintain competitiveness, industries must maintain a high level of efficiency and reliability. This has led to the shift to condition monitoring from scheduled maintenance schemes especially for expensive assets which are not immediately replaceable such as power transformers. High current surges impacting power transformers often cause winding deformations. These pose safety risks and heavy financial losses to the utility in spot market buying when failures occur. Long replacement times can have crippling financial effects on a company if there is no replacement for the transformer when a failure occurs. As a result of this diagnostic methods which estimate the transformer condition have become increasingly important. These allow personnel to make decisions on replacing or relocating a power transformer, in keeping with the financial objectives of the company. In this report an overview of the methods used in obtaining winding signatures used for condition monitoring is presented. An equivalent circuit winding model based on multiphase transmission line theory is developed which includes enough detail to allow for an accurate simulation. The circuit model for a specific transformer winding was implemented using Microtran software. The model was used to compare the response of the commonly used transadmittance signature to the characteristic impedance signature of the winding for different types of deformations (simulated by changing different capacitances in the model). It was found that the methods were comparable in sensitivity with the transadmittance being only marginally better. The characteristic impedance signature however had the advantage of showing a constant percentage change over its frequency range for a given distortion. This makes it easier to quantify winding movement. The use of both methods in conjunction may serve as a more efficient method of classifying physical winding changes. === Applied Science, Faculty of === Electrical and Computer Engineering, Department of === Graduate
author Singh, Arvind
spellingShingle Singh, Arvind
High frequency simulation of transformer windings for diagnostic tests
author_facet Singh, Arvind
author_sort Singh, Arvind
title High frequency simulation of transformer windings for diagnostic tests
title_short High frequency simulation of transformer windings for diagnostic tests
title_full High frequency simulation of transformer windings for diagnostic tests
title_fullStr High frequency simulation of transformer windings for diagnostic tests
title_full_unstemmed High frequency simulation of transformer windings for diagnostic tests
title_sort high frequency simulation of transformer windings for diagnostic tests
publishDate 2010
url http://hdl.handle.net/2429/17550
work_keys_str_mv AT singharvind highfrequencysimulationoftransformerwindingsfordiagnostictests