Energy storage in a densely-built mediterranean city centre

The complex, three-dimensional nature of an urban area and the challenges inherent in directly measuring urban energy storage flux (ΔQs) have led to this heat flux being an understudied component of the urban surface energy balance. The primary goal of this research is to compare the relative abilit...

Full description

Bibliographic Details
Main Author: Roberts, Sarah Marie
Format: Others
Language:English
Published: 2009
Online Access:http://hdl.handle.net/2429/14405
id ndltd-UBC-oai-circle.library.ubc.ca-2429-14405
record_format oai_dc
spelling ndltd-UBC-oai-circle.library.ubc.ca-2429-144052018-01-05T17:37:17Z Energy storage in a densely-built mediterranean city centre Roberts, Sarah Marie The complex, three-dimensional nature of an urban area and the challenges inherent in directly measuring urban energy storage flux (ΔQs) have led to this heat flux being an understudied component of the urban surface energy balance. The primary goal of this research is to compare the relative ability of several different methods to estimate the magnitude and temporal variation of ΔQs in an urban environment against those obtained as in observed energy balances. The investigation is based on results from a site in the center of Marseille, France. This locale provides an ideal environment for this study, because it has a warm, dry climate (hence sensible heat dominates) and massive urban development (hence a large thermal mass), so that heat storage is likely to be a significant part of the overall surface energy balance. Estimates of ΔQs obtained from tower-mounted instruments (the energy balance residual approach) are compared to results from a parameterization scheme (Objective Hysteresis Model, OHM), a localscale numerical model (Town Energy Balance, TEB), and a bulk heat transfer approach (Thermal Mass Scheme, TMS). Meteorological and urban construction data are used as inputs to the methods. Two-dimensional and three-dimensional formulations of the OHM do not sufficiently handle surface-atmosphere sensible heat exchanges in this highly urbanized and windy environment while TEB shows good agreement with the residual approach. TMS values are comparable to those from the other two methods but the laborious nature of the approach renders it impractical in such a complex setting. TEB's good performance at this site, as well as at other dry urban settings (central Mexico City and a light industrial site in Vancouver, British Columbia), suggest it possesses promise as a basis for further analyses and sensitivity tests designed to better understand the impacts of varying flow regimes, building geometry and materials on local-scale urban surface-atmosphere energy exchanges. Such an analysis was performed and the results reveal that the wind regime plays a dominant role in surface-atmosphere energy partitioning in this environment. Varying urban geometry and surface radiative properties also result in appreciable changes whereas alterations to surface thermal parameters generate the least impact. Science, Faculty of Earth, Ocean and Atmospheric Sciences, Department of Graduate 2009-10-29T19:41:38Z 2009-10-29T19:41:38Z 2003 2003-11 Text Thesis/Dissertation http://hdl.handle.net/2429/14405 eng For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use. 24312053 bytes application/pdf
collection NDLTD
language English
format Others
sources NDLTD
description The complex, three-dimensional nature of an urban area and the challenges inherent in directly measuring urban energy storage flux (ΔQs) have led to this heat flux being an understudied component of the urban surface energy balance. The primary goal of this research is to compare the relative ability of several different methods to estimate the magnitude and temporal variation of ΔQs in an urban environment against those obtained as in observed energy balances. The investigation is based on results from a site in the center of Marseille, France. This locale provides an ideal environment for this study, because it has a warm, dry climate (hence sensible heat dominates) and massive urban development (hence a large thermal mass), so that heat storage is likely to be a significant part of the overall surface energy balance. Estimates of ΔQs obtained from tower-mounted instruments (the energy balance residual approach) are compared to results from a parameterization scheme (Objective Hysteresis Model, OHM), a localscale numerical model (Town Energy Balance, TEB), and a bulk heat transfer approach (Thermal Mass Scheme, TMS). Meteorological and urban construction data are used as inputs to the methods. Two-dimensional and three-dimensional formulations of the OHM do not sufficiently handle surface-atmosphere sensible heat exchanges in this highly urbanized and windy environment while TEB shows good agreement with the residual approach. TMS values are comparable to those from the other two methods but the laborious nature of the approach renders it impractical in such a complex setting. TEB's good performance at this site, as well as at other dry urban settings (central Mexico City and a light industrial site in Vancouver, British Columbia), suggest it possesses promise as a basis for further analyses and sensitivity tests designed to better understand the impacts of varying flow regimes, building geometry and materials on local-scale urban surface-atmosphere energy exchanges. Such an analysis was performed and the results reveal that the wind regime plays a dominant role in surface-atmosphere energy partitioning in this environment. Varying urban geometry and surface radiative properties also result in appreciable changes whereas alterations to surface thermal parameters generate the least impact. === Science, Faculty of === Earth, Ocean and Atmospheric Sciences, Department of === Graduate
author Roberts, Sarah Marie
spellingShingle Roberts, Sarah Marie
Energy storage in a densely-built mediterranean city centre
author_facet Roberts, Sarah Marie
author_sort Roberts, Sarah Marie
title Energy storage in a densely-built mediterranean city centre
title_short Energy storage in a densely-built mediterranean city centre
title_full Energy storage in a densely-built mediterranean city centre
title_fullStr Energy storage in a densely-built mediterranean city centre
title_full_unstemmed Energy storage in a densely-built mediterranean city centre
title_sort energy storage in a densely-built mediterranean city centre
publishDate 2009
url http://hdl.handle.net/2429/14405
work_keys_str_mv AT robertssarahmarie energystorageinadenselybuiltmediterraneancitycentre
_version_ 1718589611412815872