Wearable radar sensor for non-contact pulse transit time measurement.

碩士 === 國立中山大學 === 電機工程學系研究所 === 107 === This thesis presents a non-contact radar system. This non-contact radar system uses wearable microstrip antenna in a single-frequency continuous-wave radar which operates concurrently with two different modes. The two different modes are: self-injection-locked...

Full description

Bibliographic Details
Main Authors: Chien-Min Liao, 廖健閔
Other Authors: Tzyy-Sheng Horng
Format: Others
Language:zh-TW
Published: 2018
Online Access:http://ndltd.ncl.edu.tw/handle/6q7mm7
id ndltd-TW-107NSYS5442002
record_format oai_dc
spelling ndltd-TW-107NSYS54420022019-05-16T01:40:47Z http://ndltd.ncl.edu.tw/handle/6q7mm7 Wearable radar sensor for non-contact pulse transit time measurement. 應用於非接觸脈搏傳遞時間量測之穿戴式雷達感測裝置 Chien-Min Liao 廖健閔 碩士 國立中山大學 電機工程學系研究所 107 This thesis presents a non-contact radar system. This non-contact radar system uses wearable microstrip antenna in a single-frequency continuous-wave radar which operates concurrently with two different modes. The two different modes are: self-injection-locked CW mode (SIL mode) and range-correlated CW mode (RC CW mode). Then, the Labview software is used to collect the data and calculate the pulse transmit time. To conduct this experiment, three antennas are designed first. These three antennas are: rectangular microstrip antenna, loop microstrip antenna, and flexible antenna. These three antennas are used in the radar system to detect human’s pulse and heartbeats. Also, the influences of human body on the antenna are taken into consideration. Second, these three antennas are applied in the radar system, operating with two modes, ie, SIL mode and RC CW mode. The radar system utilizes a voltage control oscillator with injection port to transmit RF signal to wrist and chest antennas through the power splitter. The wrist antenna detects movement due to pulse and makes oscillator enter the SIL state. And thus, a frequency demodulator can be used to obtain the waveform of pulse. On the other hand, the chest antenna detects the movements due to heartbeats and then an IQ demodulator can be used to obtain the waveform of heartbeats. Based on Biopac company’s pulse transit time measurement using electrocardiography and photolethysmography sensors, the results show that the peak time difference between the two resultant output signals in the radar system is closely correlated with the pulse transit time. Compared to other contact sensors, the presented wearable physiological monitoring radar system takes the advantages of low cost, convenience, and comfort. Tzyy-Sheng Horng 洪子聖 2018 學位論文 ; thesis 74 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立中山大學 === 電機工程學系研究所 === 107 === This thesis presents a non-contact radar system. This non-contact radar system uses wearable microstrip antenna in a single-frequency continuous-wave radar which operates concurrently with two different modes. The two different modes are: self-injection-locked CW mode (SIL mode) and range-correlated CW mode (RC CW mode). Then, the Labview software is used to collect the data and calculate the pulse transmit time. To conduct this experiment, three antennas are designed first. These three antennas are: rectangular microstrip antenna, loop microstrip antenna, and flexible antenna. These three antennas are used in the radar system to detect human’s pulse and heartbeats. Also, the influences of human body on the antenna are taken into consideration. Second, these three antennas are applied in the radar system, operating with two modes, ie, SIL mode and RC CW mode. The radar system utilizes a voltage control oscillator with injection port to transmit RF signal to wrist and chest antennas through the power splitter. The wrist antenna detects movement due to pulse and makes oscillator enter the SIL state. And thus, a frequency demodulator can be used to obtain the waveform of pulse. On the other hand, the chest antenna detects the movements due to heartbeats and then an IQ demodulator can be used to obtain the waveform of heartbeats. Based on Biopac company’s pulse transit time measurement using electrocardiography and photolethysmography sensors, the results show that the peak time difference between the two resultant output signals in the radar system is closely correlated with the pulse transit time. Compared to other contact sensors, the presented wearable physiological monitoring radar system takes the advantages of low cost, convenience, and comfort.
author2 Tzyy-Sheng Horng
author_facet Tzyy-Sheng Horng
Chien-Min Liao
廖健閔
author Chien-Min Liao
廖健閔
spellingShingle Chien-Min Liao
廖健閔
Wearable radar sensor for non-contact pulse transit time measurement.
author_sort Chien-Min Liao
title Wearable radar sensor for non-contact pulse transit time measurement.
title_short Wearable radar sensor for non-contact pulse transit time measurement.
title_full Wearable radar sensor for non-contact pulse transit time measurement.
title_fullStr Wearable radar sensor for non-contact pulse transit time measurement.
title_full_unstemmed Wearable radar sensor for non-contact pulse transit time measurement.
title_sort wearable radar sensor for non-contact pulse transit time measurement.
publishDate 2018
url http://ndltd.ncl.edu.tw/handle/6q7mm7
work_keys_str_mv AT chienminliao wearableradarsensorfornoncontactpulsetransittimemeasurement
AT liàojiànmǐn wearableradarsensorfornoncontactpulsetransittimemeasurement
AT chienminliao yīngyòngyúfēijiēchùmàibóchuándìshíjiānliàngcèzhīchuāndàishìléidágǎncèzhuāngzhì
AT liàojiànmǐn yīngyòngyúfēijiēchùmàibóchuándìshíjiānliàngcèzhīchuāndàishìléidágǎncèzhuāngzhì
_version_ 1719178962006966272