Refractive index measurement system based on total internal reflection maximum phase difference

碩士 === 國立中央大學 === 光機電工程研究所 === 107 === This study developed a refractive index measurement system to improve the problems encountered in the measurement of refractive index of liquids and solids currently. The developed system architecture introduces different phase delays based on the reflected lig...

Full description

Bibliographic Details
Main Authors: Tzu-Yang Weng, 翁子揚
Other Authors: Ju-Yi Lee
Format: Others
Language:zh-TW
Published: 2019
Online Access:http://ndltd.ncl.edu.tw/handle/hv837m
id ndltd-TW-107NCU05651016
record_format oai_dc
spelling ndltd-TW-107NCU056510162019-10-22T05:28:15Z http://ndltd.ncl.edu.tw/handle/hv837m Refractive index measurement system based on total internal reflection maximum phase difference 基於全反射相位差極大值之折射率量測系統 Tzu-Yang Weng 翁子揚 碩士 國立中央大學 光機電工程研究所 107 This study developed a refractive index measurement system to improve the problems encountered in the measurement of refractive index of liquids and solids currently. The developed system architecture introduces different phase delays based on the reflected light of the vertical and horizontal polarization states when total reflection occurs. By calculating the maximum value of the phase difference between the vertical and horizontal delay phases, and finding the phase difference maximum value and the relationship between the refractive indices and the refractive index is derived. The system uses the focusing method to incident laser beam into the prism, and the incident angle of the laser beam is a range. Compared with the conventional single-incident angle total reflection measurement system, the system does not need to adjust the incident angle very precisely. And the optical path adjustment is relatively simple and fast. In the measurement experiment, the medium to be tested is represented by three types of ambient air, tap water and glass of different refractive indices. When the sample is ambient air and tap water, the interface between the sample and the prism is tightly coupled, through the measurement area of the xyz axis can easily move the focused spot between the prism and the sample, and make the totally reflective happended. When the sample is glass, it is necessary to add an index matching oil which is consistent with the refractive index of the prism between the prism and the sample, and to move the spot to the surface of the sample through the xyz axis movement of the measurement area. The purpose of this system is to analyze the phase delay of the vertical and horizontal polarization through two light intensities with a polarization direction of ±45 degrees. Since the light source is in focus, the measurement point focused on the surface of the object to be tested and the received light intensity of the linear CCD camera, the position is the object image relationship. When measuring, must make sure the surface of the sample is clean. Otherwise, the scratches, dust or impurities on III the surface of the sample will be measured on the linear CCD camera. The measurement performance of the system was verified by measurement experiments of ambient air, tap water and glass samples with different refractive indices. The system resolution was 0.0079. Ju-Yi Lee 李朱育 2019 學位論文 ; thesis 84 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立中央大學 === 光機電工程研究所 === 107 === This study developed a refractive index measurement system to improve the problems encountered in the measurement of refractive index of liquids and solids currently. The developed system architecture introduces different phase delays based on the reflected light of the vertical and horizontal polarization states when total reflection occurs. By calculating the maximum value of the phase difference between the vertical and horizontal delay phases, and finding the phase difference maximum value and the relationship between the refractive indices and the refractive index is derived. The system uses the focusing method to incident laser beam into the prism, and the incident angle of the laser beam is a range. Compared with the conventional single-incident angle total reflection measurement system, the system does not need to adjust the incident angle very precisely. And the optical path adjustment is relatively simple and fast. In the measurement experiment, the medium to be tested is represented by three types of ambient air, tap water and glass of different refractive indices. When the sample is ambient air and tap water, the interface between the sample and the prism is tightly coupled, through the measurement area of the xyz axis can easily move the focused spot between the prism and the sample, and make the totally reflective happended. When the sample is glass, it is necessary to add an index matching oil which is consistent with the refractive index of the prism between the prism and the sample, and to move the spot to the surface of the sample through the xyz axis movement of the measurement area. The purpose of this system is to analyze the phase delay of the vertical and horizontal polarization through two light intensities with a polarization direction of ±45 degrees. Since the light source is in focus, the measurement point focused on the surface of the object to be tested and the received light intensity of the linear CCD camera, the position is the object image relationship. When measuring, must make sure the surface of the sample is clean. Otherwise, the scratches, dust or impurities on III the surface of the sample will be measured on the linear CCD camera. The measurement performance of the system was verified by measurement experiments of ambient air, tap water and glass samples with different refractive indices. The system resolution was 0.0079.
author2 Ju-Yi Lee
author_facet Ju-Yi Lee
Tzu-Yang Weng
翁子揚
author Tzu-Yang Weng
翁子揚
spellingShingle Tzu-Yang Weng
翁子揚
Refractive index measurement system based on total internal reflection maximum phase difference
author_sort Tzu-Yang Weng
title Refractive index measurement system based on total internal reflection maximum phase difference
title_short Refractive index measurement system based on total internal reflection maximum phase difference
title_full Refractive index measurement system based on total internal reflection maximum phase difference
title_fullStr Refractive index measurement system based on total internal reflection maximum phase difference
title_full_unstemmed Refractive index measurement system based on total internal reflection maximum phase difference
title_sort refractive index measurement system based on total internal reflection maximum phase difference
publishDate 2019
url http://ndltd.ncl.edu.tw/handle/hv837m
work_keys_str_mv AT tzuyangweng refractiveindexmeasurementsystembasedontotalinternalreflectionmaximumphasedifference
AT wēngziyáng refractiveindexmeasurementsystembasedontotalinternalreflectionmaximumphasedifference
AT tzuyangweng jīyúquánfǎnshèxiāngwèichàjídàzhízhīzhéshèlǜliàngcèxìtǒng
AT wēngziyáng jīyúquánfǎnshèxiāngwèichàjídàzhízhīzhéshèlǜliàngcèxìtǒng
_version_ 1719274383744172032