Magnetic Graphitized Carbon Black Combined with Gas Chromatography-Tandem Mass Spectrometry for Determination of Hydroxyl Polycyclic Aromatic Hydrocarbons in Urine

碩士 === 國立中興大學 === 化學系所 === 107 === In this study, a simple and sensitive analytical method using magnetic solid phase extraction (MSPE) combined with gas chromatography–tandem mass spectrometry (GC-MS/MS) was developed to determine hydroxyl polycyclic aromatic hydrocarbons (OH-PAHs) in human urine....

Full description

Bibliographic Details
Main Authors: Pin-An Chen, 陳品安
Other Authors: Maw-Rong Lee
Format: Others
Language:zh-TW
Published: 2019
Online Access:http://ndltd.ncl.edu.tw/handle/g2t2x4
id ndltd-TW-107NCHU5065055
record_format oai_dc
spelling ndltd-TW-107NCHU50650552019-11-29T05:36:25Z http://ndltd.ncl.edu.tw/handle/g2t2x4 Magnetic Graphitized Carbon Black Combined with Gas Chromatography-Tandem Mass Spectrometry for Determination of Hydroxyl Polycyclic Aromatic Hydrocarbons in Urine 磁性石墨化碳黑奈米粒子結合氣相層析串聯質譜術偵測尿液中羥基多環芳香烴之研究 Pin-An Chen 陳品安 碩士 國立中興大學 化學系所 107 In this study, a simple and sensitive analytical method using magnetic solid phase extraction (MSPE) combined with gas chromatography–tandem mass spectrometry (GC-MS/MS) was developed to determine hydroxyl polycyclic aromatic hydrocarbons (OH-PAHs) in human urine. The magnetic graphitized carbon black (MGCB) was utilized as sorbent in dispersive solid phase extraction to extract OH-PAHs in urine sample. The results showed that OH-PAHs in 2 mL urine sample was extracted by 10 mg/mL MGCB under sonicated for 10 seconds. Subsequently, the adsorbed OH-PAHs were eluted by using 500 µL ethyl acetate twice under sonicated for 20 second. After derivatization step, the analytes were ionized by electron ionization (EI) and quantified by using selected reaction monitoring (SRM). Under the optimal extraction and detection conditions, the linear range of the proposed method for detection of OH-PAHs were between 1-20000 pg/mL with coefficient of determination above 0.9933. The intra-day and inter-day precisions were 0.3-7.7% and 1.9-18.2%, respectively. The limit of detection (LOD) were in the range of 0.2-33 pg/mL. The proposed method was tested by analyzing of trace OH-PAHs in real human urine samples. The trace OH-PAHs were successfully detected by the proposed method with concentration between 1-59715 pg/mL. The results showed the proposed method can be applied to determine the trace OH-PAHs in human urine. Maw-Rong Lee He-Hsuan Hsiao 李茂榮 蕭鶴軒 2019 學位論文 ; thesis 89 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立中興大學 === 化學系所 === 107 === In this study, a simple and sensitive analytical method using magnetic solid phase extraction (MSPE) combined with gas chromatography–tandem mass spectrometry (GC-MS/MS) was developed to determine hydroxyl polycyclic aromatic hydrocarbons (OH-PAHs) in human urine. The magnetic graphitized carbon black (MGCB) was utilized as sorbent in dispersive solid phase extraction to extract OH-PAHs in urine sample. The results showed that OH-PAHs in 2 mL urine sample was extracted by 10 mg/mL MGCB under sonicated for 10 seconds. Subsequently, the adsorbed OH-PAHs were eluted by using 500 µL ethyl acetate twice under sonicated for 20 second. After derivatization step, the analytes were ionized by electron ionization (EI) and quantified by using selected reaction monitoring (SRM). Under the optimal extraction and detection conditions, the linear range of the proposed method for detection of OH-PAHs were between 1-20000 pg/mL with coefficient of determination above 0.9933. The intra-day and inter-day precisions were 0.3-7.7% and 1.9-18.2%, respectively. The limit of detection (LOD) were in the range of 0.2-33 pg/mL. The proposed method was tested by analyzing of trace OH-PAHs in real human urine samples. The trace OH-PAHs were successfully detected by the proposed method with concentration between 1-59715 pg/mL. The results showed the proposed method can be applied to determine the trace OH-PAHs in human urine.
author2 Maw-Rong Lee
author_facet Maw-Rong Lee
Pin-An Chen
陳品安
author Pin-An Chen
陳品安
spellingShingle Pin-An Chen
陳品安
Magnetic Graphitized Carbon Black Combined with Gas Chromatography-Tandem Mass Spectrometry for Determination of Hydroxyl Polycyclic Aromatic Hydrocarbons in Urine
author_sort Pin-An Chen
title Magnetic Graphitized Carbon Black Combined with Gas Chromatography-Tandem Mass Spectrometry for Determination of Hydroxyl Polycyclic Aromatic Hydrocarbons in Urine
title_short Magnetic Graphitized Carbon Black Combined with Gas Chromatography-Tandem Mass Spectrometry for Determination of Hydroxyl Polycyclic Aromatic Hydrocarbons in Urine
title_full Magnetic Graphitized Carbon Black Combined with Gas Chromatography-Tandem Mass Spectrometry for Determination of Hydroxyl Polycyclic Aromatic Hydrocarbons in Urine
title_fullStr Magnetic Graphitized Carbon Black Combined with Gas Chromatography-Tandem Mass Spectrometry for Determination of Hydroxyl Polycyclic Aromatic Hydrocarbons in Urine
title_full_unstemmed Magnetic Graphitized Carbon Black Combined with Gas Chromatography-Tandem Mass Spectrometry for Determination of Hydroxyl Polycyclic Aromatic Hydrocarbons in Urine
title_sort magnetic graphitized carbon black combined with gas chromatography-tandem mass spectrometry for determination of hydroxyl polycyclic aromatic hydrocarbons in urine
publishDate 2019
url http://ndltd.ncl.edu.tw/handle/g2t2x4
work_keys_str_mv AT pinanchen magneticgraphitizedcarbonblackcombinedwithgaschromatographytandemmassspectrometryfordeterminationofhydroxylpolycyclicaromatichydrocarbonsinurine
AT chénpǐnān magneticgraphitizedcarbonblackcombinedwithgaschromatographytandemmassspectrometryfordeterminationofhydroxylpolycyclicaromatichydrocarbonsinurine
AT pinanchen cíxìngshímòhuàtànhēinàimǐlìzijiéhéqìxiāngcéngxīchuànliánzhìpǔshùzhēncèniàoyèzhōngqiǎngjīduōhuánfāngxiāngtīngzhīyánjiū
AT chénpǐnān cíxìngshímòhuàtànhēinàimǐlìzijiéhéqìxiāngcéngxīchuànliánzhìpǔshùzhēncèniàoyèzhōngqiǎngjīduōhuánfāngxiāngtīngzhīyánjiū
_version_ 1719298868888207360