Develop quality assurance procedures for multi-leaf collimation systems in linear accelerator

碩士 === 國立陽明大學 === 生物醫學影像暨放射科學系 === 106 === Cancer has been the top ten leading causes of death in Taiwan for 36 years, therefore, the cancer treatments are emphasized in our country. Radiotherapy is one of the cancer treatments, and the radiation safety and the accuracy of prescription dose are extr...

Full description

Bibliographic Details
Main Authors: Hsin-Lin Chen, 陳昕麟
Other Authors: Shih-Ming Hsu
Format: Others
Language:zh-TW
Published: 2018
Online Access:http://ndltd.ncl.edu.tw/handle/26q32z
id ndltd-TW-106YM005605012
record_format oai_dc
spelling ndltd-TW-106YM0056050122019-09-19T03:30:14Z http://ndltd.ncl.edu.tw/handle/26q32z Develop quality assurance procedures for multi-leaf collimation systems in linear accelerator 建立直線加速器多葉式準直系統之品質保證模式 Hsin-Lin Chen 陳昕麟 碩士 國立陽明大學 生物醫學影像暨放射科學系 106 Cancer has been the top ten leading causes of death in Taiwan for 36 years, therefore, the cancer treatments are emphasized in our country. Radiotherapy is one of the cancer treatments, and the radiation safety and the accuracy of prescription dose are extremely important. Mutileaf Collimation (MLC) is an indepensible component in LINAC. With the development of radiotherapy, quality assurance of MLC accuracy is increasing. According to American Association of Physicists in Medicine (AAPM) TG-142 report, the commended procedures for MLC are used in our research. Radiochromic film and electronic portal imaging devices (EPID) are used to perform the procedures. Films were common tools in dose calibration in the past, however, the process of film analysis was time consuming. On the other hand, EPID is time saving in using and analyzing. Thus, EPID was excellent in clinical calibration. In this study, the results demonstrate the importance of MLC quality assurance. Because of MLC accuracy influencing the prescription dose, we should develop quality assurance procedures for MLC to improve the cancer treatment effect. Shih-Ming Hsu 許世明 2018 學位論文 ; thesis 110 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立陽明大學 === 生物醫學影像暨放射科學系 === 106 === Cancer has been the top ten leading causes of death in Taiwan for 36 years, therefore, the cancer treatments are emphasized in our country. Radiotherapy is one of the cancer treatments, and the radiation safety and the accuracy of prescription dose are extremely important. Mutileaf Collimation (MLC) is an indepensible component in LINAC. With the development of radiotherapy, quality assurance of MLC accuracy is increasing. According to American Association of Physicists in Medicine (AAPM) TG-142 report, the commended procedures for MLC are used in our research. Radiochromic film and electronic portal imaging devices (EPID) are used to perform the procedures. Films were common tools in dose calibration in the past, however, the process of film analysis was time consuming. On the other hand, EPID is time saving in using and analyzing. Thus, EPID was excellent in clinical calibration. In this study, the results demonstrate the importance of MLC quality assurance. Because of MLC accuracy influencing the prescription dose, we should develop quality assurance procedures for MLC to improve the cancer treatment effect.
author2 Shih-Ming Hsu
author_facet Shih-Ming Hsu
Hsin-Lin Chen
陳昕麟
author Hsin-Lin Chen
陳昕麟
spellingShingle Hsin-Lin Chen
陳昕麟
Develop quality assurance procedures for multi-leaf collimation systems in linear accelerator
author_sort Hsin-Lin Chen
title Develop quality assurance procedures for multi-leaf collimation systems in linear accelerator
title_short Develop quality assurance procedures for multi-leaf collimation systems in linear accelerator
title_full Develop quality assurance procedures for multi-leaf collimation systems in linear accelerator
title_fullStr Develop quality assurance procedures for multi-leaf collimation systems in linear accelerator
title_full_unstemmed Develop quality assurance procedures for multi-leaf collimation systems in linear accelerator
title_sort develop quality assurance procedures for multi-leaf collimation systems in linear accelerator
publishDate 2018
url http://ndltd.ncl.edu.tw/handle/26q32z
work_keys_str_mv AT hsinlinchen developqualityassuranceproceduresformultileafcollimationsystemsinlinearaccelerator
AT chénxīnlín developqualityassuranceproceduresformultileafcollimationsystemsinlinearaccelerator
AT hsinlinchen jiànlìzhíxiànjiāsùqìduōyèshìzhǔnzhíxìtǒngzhīpǐnzhìbǎozhèngmóshì
AT chénxīnlín jiànlìzhíxiànjiāsùqìduōyèshìzhǔnzhíxìtǒngzhīpǐnzhìbǎozhèngmóshì
_version_ 1719252714203906048