LCC Analysis for Water Resources of HVAC Cooling Water System

碩士 === 國立臺北科技大學 === 能源與冷凍空調工程系 === 106 === In recent years, due to the high-tech development and rapid population growth, the demand for energy and water resources is increasing. The efficiency of HVAC cooling water system is greatly affected by scaling, corrosion and microbial growth. This study tr...

Full description

Bibliographic Details
Main Authors: Yu-Xin Chuang, 莊育信
Other Authors: Kuei-Peng Lee
Format: Others
Language:zh-TW
Published: 2018
Online Access:http://ndltd.ncl.edu.tw/handle/p66nnv
id ndltd-TW-106TIT05703065
record_format oai_dc
spelling ndltd-TW-106TIT057030652019-11-28T05:22:42Z http://ndltd.ncl.edu.tw/handle/p66nnv LCC Analysis for Water Resources of HVAC Cooling Water System 空調冷卻水系統之水資源生命週期成本評估與分析 Yu-Xin Chuang 莊育信 碩士 國立臺北科技大學 能源與冷凍空調工程系 106 In recent years, due to the high-tech development and rapid population growth, the demand for energy and water resources is increasing. The efficiency of HVAC cooling water system is greatly affected by scaling, corrosion and microbial growth. This study try to quantify the effect of this and obtain the calculation index of water cost. This study uses the dynamic energy simulation software EnergyPlus to build a local benchmark office building and HVAC system model with local meteorological data, to discuss the energy and water savings for different cooling tower control strategies. In this study, the concept of scaling on the cooling water side have been considered, with different water treatment methods, then using EnergyPlus to simulate the energy consumption caused by scale. Establish a Life-Cycle Cost model to calculate the total annual cost due to scaling, then divided the total annual cost by the total annual cooling capacity (kWh), then obtain a water resource calculation index $/kWh. This study found that, for different energy saving strategies, the cooling tower water leaving temperature control at 22 ° C has the highest energy saving rate of 7.44%. The cooling tower approach temperature control has the highest energy saving rate of 8.55%. For the experimental groups 11 and 35, if the efficiency of the cooling water scale inhibitor improved, the energy consumption of the HVAC system can be reduced. After calculating by the life cycle cost model, both of the unit water cost of the experimental groups 11 and 35 is reduced by $ 0.002 /kWh. For every energy saving strategy, if the condenser is cleaned once every six months, it has the lowest unit cost of $/kWh. Kuei-Peng Lee 李魁鵬 2018 學位論文 ; thesis 59 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立臺北科技大學 === 能源與冷凍空調工程系 === 106 === In recent years, due to the high-tech development and rapid population growth, the demand for energy and water resources is increasing. The efficiency of HVAC cooling water system is greatly affected by scaling, corrosion and microbial growth. This study try to quantify the effect of this and obtain the calculation index of water cost. This study uses the dynamic energy simulation software EnergyPlus to build a local benchmark office building and HVAC system model with local meteorological data, to discuss the energy and water savings for different cooling tower control strategies. In this study, the concept of scaling on the cooling water side have been considered, with different water treatment methods, then using EnergyPlus to simulate the energy consumption caused by scale. Establish a Life-Cycle Cost model to calculate the total annual cost due to scaling, then divided the total annual cost by the total annual cooling capacity (kWh), then obtain a water resource calculation index $/kWh. This study found that, for different energy saving strategies, the cooling tower water leaving temperature control at 22 ° C has the highest energy saving rate of 7.44%. The cooling tower approach temperature control has the highest energy saving rate of 8.55%. For the experimental groups 11 and 35, if the efficiency of the cooling water scale inhibitor improved, the energy consumption of the HVAC system can be reduced. After calculating by the life cycle cost model, both of the unit water cost of the experimental groups 11 and 35 is reduced by $ 0.002 /kWh. For every energy saving strategy, if the condenser is cleaned once every six months, it has the lowest unit cost of $/kWh.
author2 Kuei-Peng Lee
author_facet Kuei-Peng Lee
Yu-Xin Chuang
莊育信
author Yu-Xin Chuang
莊育信
spellingShingle Yu-Xin Chuang
莊育信
LCC Analysis for Water Resources of HVAC Cooling Water System
author_sort Yu-Xin Chuang
title LCC Analysis for Water Resources of HVAC Cooling Water System
title_short LCC Analysis for Water Resources of HVAC Cooling Water System
title_full LCC Analysis for Water Resources of HVAC Cooling Water System
title_fullStr LCC Analysis for Water Resources of HVAC Cooling Water System
title_full_unstemmed LCC Analysis for Water Resources of HVAC Cooling Water System
title_sort lcc analysis for water resources of hvac cooling water system
publishDate 2018
url http://ndltd.ncl.edu.tw/handle/p66nnv
work_keys_str_mv AT yuxinchuang lccanalysisforwaterresourcesofhvaccoolingwatersystem
AT zhuāngyùxìn lccanalysisforwaterresourcesofhvaccoolingwatersystem
AT yuxinchuang kōngdiàolěngquèshuǐxìtǒngzhīshuǐzīyuánshēngmìngzhōuqīchéngběnpínggūyǔfēnxī
AT zhuāngyùxìn kōngdiàolěngquèshuǐxìtǒngzhīshuǐzīyuánshēngmìngzhōuqīchéngběnpínggūyǔfēnxī
_version_ 1719298352223354880