Fuzzy-based Contamination Assessment for Insulators of Transmission Towers

碩士 === 國立臺灣科技大學 === 電機工程系 === 106 === Because the insulator of the transmission tower has long been exposed to the outdoors and is affected by the salt mist damage, therefore, flashover accident occurred, affecting the normal power supply, which is to avoid pollution flashover accident occurred in t...

Full description

Bibliographic Details
Main Authors: Kun-Xiang Hong, 洪堃翔
Other Authors: Hong-Chan Chang
Format: Others
Language:zh-TW
Published: 2018
Online Access:http://ndltd.ncl.edu.tw/handle/g3748k
id ndltd-TW-106NTUS5442082
record_format oai_dc
spelling ndltd-TW-106NTUS54420822019-11-28T05:22:05Z http://ndltd.ncl.edu.tw/handle/g3748k Fuzzy-based Contamination Assessment for Insulators of Transmission Towers 基於模糊法之輸電鐵塔絕緣礙子汙染評估 Kun-Xiang Hong 洪堃翔 碩士 國立臺灣科技大學 電機工程系 106 Because the insulator of the transmission tower has long been exposed to the outdoors and is affected by the salt mist damage, therefore, flashover accident occurred, affecting the normal power supply, which is to avoid pollution flashover accident occurred in the most direct and effective maintenance methods, but it takes a lot of manpower and time, so decided to interfere with the timing becomes particularly important. This research aims to use the fuzzy method to study the contamination status of transmission tower insulator. Firstly, the paper studies and analyzes the contamination flashover process of insulators, and studies the method of preventing the flashover. Then, the weather pattern "fog" with the highest proportion of contamination flashover accident of insulators is used as the assessment index of environment, by choosing the effective value of leakage current, relative humidity, temperature dew point difference and wind speed as input parameters, a set of insulator contamination degree evaluation method based on fuzzy algorithm is proposed to improve the single leakage current index can not judge that the current value is caused by the insulator pollution or the environmental humidity. Finally, through the case analysis to verify that the system has the same assessment result with the electric operators and analysis results are displayed on the Web page to provide maintenance personnel to understand the insulator real-time information to avoid the occurrence of pollution flashover accident. Hong-Chan Chang 張宏展 2018 學位論文 ; thesis 82 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立臺灣科技大學 === 電機工程系 === 106 === Because the insulator of the transmission tower has long been exposed to the outdoors and is affected by the salt mist damage, therefore, flashover accident occurred, affecting the normal power supply, which is to avoid pollution flashover accident occurred in the most direct and effective maintenance methods, but it takes a lot of manpower and time, so decided to interfere with the timing becomes particularly important. This research aims to use the fuzzy method to study the contamination status of transmission tower insulator. Firstly, the paper studies and analyzes the contamination flashover process of insulators, and studies the method of preventing the flashover. Then, the weather pattern "fog" with the highest proportion of contamination flashover accident of insulators is used as the assessment index of environment, by choosing the effective value of leakage current, relative humidity, temperature dew point difference and wind speed as input parameters, a set of insulator contamination degree evaluation method based on fuzzy algorithm is proposed to improve the single leakage current index can not judge that the current value is caused by the insulator pollution or the environmental humidity. Finally, through the case analysis to verify that the system has the same assessment result with the electric operators and analysis results are displayed on the Web page to provide maintenance personnel to understand the insulator real-time information to avoid the occurrence of pollution flashover accident.
author2 Hong-Chan Chang
author_facet Hong-Chan Chang
Kun-Xiang Hong
洪堃翔
author Kun-Xiang Hong
洪堃翔
spellingShingle Kun-Xiang Hong
洪堃翔
Fuzzy-based Contamination Assessment for Insulators of Transmission Towers
author_sort Kun-Xiang Hong
title Fuzzy-based Contamination Assessment for Insulators of Transmission Towers
title_short Fuzzy-based Contamination Assessment for Insulators of Transmission Towers
title_full Fuzzy-based Contamination Assessment for Insulators of Transmission Towers
title_fullStr Fuzzy-based Contamination Assessment for Insulators of Transmission Towers
title_full_unstemmed Fuzzy-based Contamination Assessment for Insulators of Transmission Towers
title_sort fuzzy-based contamination assessment for insulators of transmission towers
publishDate 2018
url http://ndltd.ncl.edu.tw/handle/g3748k
work_keys_str_mv AT kunxianghong fuzzybasedcontaminationassessmentforinsulatorsoftransmissiontowers
AT hóngkūnxiáng fuzzybasedcontaminationassessmentforinsulatorsoftransmissiontowers
AT kunxianghong jīyúmóhúfǎzhīshūdiàntiětǎjuéyuánàiziwūrǎnpínggū
AT hóngkūnxiáng jīyúmóhúfǎzhīshūdiàntiětǎjuéyuánàiziwūrǎnpínggū
_version_ 1719297041531666432