Evaluating the Harmonic Filters on the Harmonic Current Distortion of Voltage Source Inverter-Fed Drives

博士 === 國立臺灣科技大學 === 電機工程系 === 106 === The main purpose of this dissertation is to investigate the impact of harmonic filter applications on the harmonic current distortion of Voltage Source Inverter-fed drives (VSI) and improving strategies. In general, the nonlinear loads are assumed as a constant...

Full description

Bibliographic Details
Main Authors: Wei-Hsiang Ko, 柯唯翔
Other Authors: Jyh-Cherng Gu
Format: Others
Language:zh-TW
Published: 2018
Online Access:http://ndltd.ncl.edu.tw/handle/s2g64a
id ndltd-TW-106NTUS5442016
record_format oai_dc
spelling ndltd-TW-106NTUS54420162019-05-16T00:15:35Z http://ndltd.ncl.edu.tw/handle/s2g64a Evaluating the Harmonic Filters on the Harmonic Current Distortion of Voltage Source Inverter-Fed Drives 諧波濾波器對電壓源型變流器諧波電流影響之研究 Wei-Hsiang Ko 柯唯翔 博士 國立臺灣科技大學 電機工程系 106 The main purpose of this dissertation is to investigate the impact of harmonic filter applications on the harmonic current distortion of Voltage Source Inverter-fed drives (VSI) and improving strategies. In general, the nonlinear loads are assumed as a constant harmonic current source in harmonic analysis of power systems. However, when an active or passive harmonic filter is invited to mitigate the harmonics produced by the VSI load, the total harmonic current distortion of the load actually changes. The increasing of the VSI total harmonic current distortion will lead to the unexpected harmonic improving result at system side, and cause insufficient harmonic carrying capability, such as the rated voltage and rated current of the passive harmonic filter. In order to analyze the causes and main influencing factors of this harmonic changing phenomenon, a VSI equivalent circuit is established in this study, and its ac side harmonic current transformation equation is also derived in this investigation. The whole and selective harmonic compensation control models of the active harmonic filter are deduced, as well as the equivalent harmonic model of passive harmonic filters. In this reaseach, correlation analysis system models are constructed and simulated to illustrate the impact of different system short-circiut levels, VSI loadings, ac choke reactors of the VSI, and different filter compensation modes on the harmonic current distortion of the VSI. Then, the simulation and measurement results are used to summarize the causes of this phenomenon and the main influencing factors. Furthermore, this research proposed a design method for active and passive harmonic filters, which optimizes the system harmonic improvement results, and effectively solves the application problems of the active and the passive harmonic filters. Finally, from the simulation and field measurement results, the dissertation is of value to solve the harmonic improving problems on the active and passive harmonic filter applications. Jyh-Cherng Gu 辜志承 2018 學位論文 ; thesis 150 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 博士 === 國立臺灣科技大學 === 電機工程系 === 106 === The main purpose of this dissertation is to investigate the impact of harmonic filter applications on the harmonic current distortion of Voltage Source Inverter-fed drives (VSI) and improving strategies. In general, the nonlinear loads are assumed as a constant harmonic current source in harmonic analysis of power systems. However, when an active or passive harmonic filter is invited to mitigate the harmonics produced by the VSI load, the total harmonic current distortion of the load actually changes. The increasing of the VSI total harmonic current distortion will lead to the unexpected harmonic improving result at system side, and cause insufficient harmonic carrying capability, such as the rated voltage and rated current of the passive harmonic filter. In order to analyze the causes and main influencing factors of this harmonic changing phenomenon, a VSI equivalent circuit is established in this study, and its ac side harmonic current transformation equation is also derived in this investigation. The whole and selective harmonic compensation control models of the active harmonic filter are deduced, as well as the equivalent harmonic model of passive harmonic filters. In this reaseach, correlation analysis system models are constructed and simulated to illustrate the impact of different system short-circiut levels, VSI loadings, ac choke reactors of the VSI, and different filter compensation modes on the harmonic current distortion of the VSI. Then, the simulation and measurement results are used to summarize the causes of this phenomenon and the main influencing factors. Furthermore, this research proposed a design method for active and passive harmonic filters, which optimizes the system harmonic improvement results, and effectively solves the application problems of the active and the passive harmonic filters. Finally, from the simulation and field measurement results, the dissertation is of value to solve the harmonic improving problems on the active and passive harmonic filter applications.
author2 Jyh-Cherng Gu
author_facet Jyh-Cherng Gu
Wei-Hsiang Ko
柯唯翔
author Wei-Hsiang Ko
柯唯翔
spellingShingle Wei-Hsiang Ko
柯唯翔
Evaluating the Harmonic Filters on the Harmonic Current Distortion of Voltage Source Inverter-Fed Drives
author_sort Wei-Hsiang Ko
title Evaluating the Harmonic Filters on the Harmonic Current Distortion of Voltage Source Inverter-Fed Drives
title_short Evaluating the Harmonic Filters on the Harmonic Current Distortion of Voltage Source Inverter-Fed Drives
title_full Evaluating the Harmonic Filters on the Harmonic Current Distortion of Voltage Source Inverter-Fed Drives
title_fullStr Evaluating the Harmonic Filters on the Harmonic Current Distortion of Voltage Source Inverter-Fed Drives
title_full_unstemmed Evaluating the Harmonic Filters on the Harmonic Current Distortion of Voltage Source Inverter-Fed Drives
title_sort evaluating the harmonic filters on the harmonic current distortion of voltage source inverter-fed drives
publishDate 2018
url http://ndltd.ncl.edu.tw/handle/s2g64a
work_keys_str_mv AT weihsiangko evaluatingtheharmonicfiltersontheharmoniccurrentdistortionofvoltagesourceinverterfeddrives
AT kēwéixiáng evaluatingtheharmonicfiltersontheharmoniccurrentdistortionofvoltagesourceinverterfeddrives
AT weihsiangko xiébōlǜbōqìduìdiànyāyuánxíngbiànliúqìxiébōdiànliúyǐngxiǎngzhīyánjiū
AT kēwéixiáng xiébōlǜbōqìduìdiànyāyuánxíngbiànliúqìxiébōdiànliúyǐngxiǎngzhīyánjiū
_version_ 1719163927680516096