Investigation of the Feasibility Using Centrifugal Microdevice Coupled with Simple Image Analysis Technique for Rapid Determination of Chromium(VI) in Natural Water

碩士 === 國立清華大學 === 生醫工程與環境科學系 === 106 === Environmental pollution caused by chromium (Cr) is closely related to the industrial activities, such as steel, leather, pigment and rubber industries. Typically, Cr exists either as cationic trivalent species (i.e., Cr(III)) or anionic hexavalent species (i....

Full description

Bibliographic Details
Main Authors: Chu, Ying-Hua, 朱盈樺
Other Authors: Sun, Yuh-Chang
Format: Others
Language:zh-TW
Published: 2018
Online Access:http://ndltd.ncl.edu.tw/handle/4765j2
id ndltd-TW-106NTHU5810023
record_format oai_dc
spelling ndltd-TW-106NTHU58100232019-05-16T00:15:34Z http://ndltd.ncl.edu.tw/handle/4765j2 Investigation of the Feasibility Using Centrifugal Microdevice Coupled with Simple Image Analysis Technique for Rapid Determination of Chromium(VI) in Natural Water 結合簡易影像分析技術及離心式微流體裝置發展快速定量環境水樣中六價鉻分析技術之可行性評估 Chu, Ying-Hua 朱盈樺 碩士 國立清華大學 生醫工程與環境科學系 106 Environmental pollution caused by chromium (Cr) is closely related to the industrial activities, such as steel, leather, pigment and rubber industries. Typically, Cr exists either as cationic trivalent species (i.e., Cr(III)) or anionic hexavalent species (i.e., Cr(VI)). Cr(III) species are essential in protein and lipid metabolism. In contrast, Cr(VI) species are capable of inducing deoxyribonucleic acid (DNA) damage leading to potential cell transforming effects. Considering Cr(III) species are prone to form more toxic Cr(VI) species in the environment, the determination of Cr(VI) is critical for evaluating their impacts on the environment and human being. Over past decades, the microfluidic-based technology has emerged as a popular methodology for analytical work due to their unique advantages such as low reagent/power consumption, portability for in-situ use, low fabrication cost, and versatile design. Among several microfluidic-based techniques available, centrifugal microdevices have attracted much attention in recent years. Compared to the usual methods for fluid manipulation in miniaturized systems, the sample/reagent solutions are driven by centrifugal force without the use of any other pumping equipment. Thus, more compact designs for analytical systems can be expected. In this study, we developed a centrifugal device including a glucamine-packed solid phase extraction column and in-channel flow control valves. After coupling the developed centrifugal device to simple image analysis tools. Under the optimized condition, it merely needed 15 minutes to analyze six samples in a single run. The limit of detection of Cr(VI) were 1.69 mg L─1. Based on the analytical results, the proposed system was proven to be a promising platform for determination of Cr(VI). Sun, Yuh-Chang 孫毓璋 2018 學位論文 ; thesis 55 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立清華大學 === 生醫工程與環境科學系 === 106 === Environmental pollution caused by chromium (Cr) is closely related to the industrial activities, such as steel, leather, pigment and rubber industries. Typically, Cr exists either as cationic trivalent species (i.e., Cr(III)) or anionic hexavalent species (i.e., Cr(VI)). Cr(III) species are essential in protein and lipid metabolism. In contrast, Cr(VI) species are capable of inducing deoxyribonucleic acid (DNA) damage leading to potential cell transforming effects. Considering Cr(III) species are prone to form more toxic Cr(VI) species in the environment, the determination of Cr(VI) is critical for evaluating their impacts on the environment and human being. Over past decades, the microfluidic-based technology has emerged as a popular methodology for analytical work due to their unique advantages such as low reagent/power consumption, portability for in-situ use, low fabrication cost, and versatile design. Among several microfluidic-based techniques available, centrifugal microdevices have attracted much attention in recent years. Compared to the usual methods for fluid manipulation in miniaturized systems, the sample/reagent solutions are driven by centrifugal force without the use of any other pumping equipment. Thus, more compact designs for analytical systems can be expected. In this study, we developed a centrifugal device including a glucamine-packed solid phase extraction column and in-channel flow control valves. After coupling the developed centrifugal device to simple image analysis tools. Under the optimized condition, it merely needed 15 minutes to analyze six samples in a single run. The limit of detection of Cr(VI) were 1.69 mg L─1. Based on the analytical results, the proposed system was proven to be a promising platform for determination of Cr(VI).
author2 Sun, Yuh-Chang
author_facet Sun, Yuh-Chang
Chu, Ying-Hua
朱盈樺
author Chu, Ying-Hua
朱盈樺
spellingShingle Chu, Ying-Hua
朱盈樺
Investigation of the Feasibility Using Centrifugal Microdevice Coupled with Simple Image Analysis Technique for Rapid Determination of Chromium(VI) in Natural Water
author_sort Chu, Ying-Hua
title Investigation of the Feasibility Using Centrifugal Microdevice Coupled with Simple Image Analysis Technique for Rapid Determination of Chromium(VI) in Natural Water
title_short Investigation of the Feasibility Using Centrifugal Microdevice Coupled with Simple Image Analysis Technique for Rapid Determination of Chromium(VI) in Natural Water
title_full Investigation of the Feasibility Using Centrifugal Microdevice Coupled with Simple Image Analysis Technique for Rapid Determination of Chromium(VI) in Natural Water
title_fullStr Investigation of the Feasibility Using Centrifugal Microdevice Coupled with Simple Image Analysis Technique for Rapid Determination of Chromium(VI) in Natural Water
title_full_unstemmed Investigation of the Feasibility Using Centrifugal Microdevice Coupled with Simple Image Analysis Technique for Rapid Determination of Chromium(VI) in Natural Water
title_sort investigation of the feasibility using centrifugal microdevice coupled with simple image analysis technique for rapid determination of chromium(vi) in natural water
publishDate 2018
url http://ndltd.ncl.edu.tw/handle/4765j2
work_keys_str_mv AT chuyinghua investigationofthefeasibilityusingcentrifugalmicrodevicecoupledwithsimpleimageanalysistechniqueforrapiddeterminationofchromiumviinnaturalwater
AT zhūyínghuà investigationofthefeasibilityusingcentrifugalmicrodevicecoupledwithsimpleimageanalysistechniqueforrapiddeterminationofchromiumviinnaturalwater
AT chuyinghua jiéhéjiǎnyìyǐngxiàngfēnxījìshùjílíxīnshìwēiliútǐzhuāngzhìfāzhǎnkuàisùdìngliànghuánjìngshuǐyàngzhōngliùjiàluòfēnxījìshùzhīkěxíngxìngpínggū
AT zhūyínghuà jiéhéjiǎnyìyǐngxiàngfēnxījìshùjílíxīnshìwēiliútǐzhuāngzhìfāzhǎnkuàisùdìngliànghuánjìngshuǐyàngzhōngliùjiàluòfēnxījìshùzhīkěxíngxìngpínggū
_version_ 1719163143308967936