Explore the Application with Automatic Exposure Control Technology in Simulating Different Abdomen Phantom

碩士 === 中臺科技大學 === 醫學影像暨放射科學系暨研究所 === 106 === This study investigated the relationship between the exposure of thickness and tube voltage. To evaluate the radiation dose appropriation for the automatic exposure control (AEC) in abdominal radiography of obese patients. The values of the exposure facto...

Full description

Bibliographic Details
Main Authors: HUANG, BO-YEN, 黃柏諺
Other Authors: CHEN, CHIA-HUI
Format: Others
Language:zh-TW
Published: 2018
Online Access:http://ndltd.ncl.edu.tw/handle/9gw3eq
id ndltd-TW-106CTC00770009
record_format oai_dc
spelling ndltd-TW-106CTC007700092019-05-30T03:50:42Z http://ndltd.ncl.edu.tw/handle/9gw3eq Explore the Application with Automatic Exposure Control Technology in Simulating Different Abdomen Phantom 探討自動曝露控制技術於模擬不同厚度腹部假體之應用 HUANG, BO-YEN 黃柏諺 碩士 中臺科技大學 醫學影像暨放射科學系暨研究所 106 This study investigated the relationship between the exposure of thickness and tube voltage. To evaluate the radiation dose appropriation for the automatic exposure control (AEC) in abdominal radiography of obese patients. The values of the exposure factors generated with various thicknesses of water phantom at 81 kVp, 85 kVp, 90 kVp, 96 kVp, and 102 kVp tube voltage were obtained by using the Phlips diagnost TH X-ray machine, the Hologic DPA/QDR-1 Anthropomorphic Spine Phantom and the self-made water phantom. Exposure dose of different phantom thicknesses under different tube voltage conditions were calculated based on the exposure factor values obtained in the above experiments. The lumbar vertebral phantom was placed in the water phantom, AEC radiography was performed on each grouping condition and the images were stored as a control group. According to the image conditions of the control group, a lower exposure factor level was used to exposure and then save the image as an experimental group. Randomly display lumbar images with the experimental group and the control group on a dual screen in the workstation the images could be distinguished that determine distinguished by 2 radiographers. Perform Cohen's kappa consistency analysis after recording the data. The result showed that AEC is suitable for thickness of 36 cm or more obese patients with a tube voltage of 102 kVp during abdomen radiography examination. CHEN, CHIA-HUI 陳佳惠 2018 學位論文 ; thesis 71 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 中臺科技大學 === 醫學影像暨放射科學系暨研究所 === 106 === This study investigated the relationship between the exposure of thickness and tube voltage. To evaluate the radiation dose appropriation for the automatic exposure control (AEC) in abdominal radiography of obese patients. The values of the exposure factors generated with various thicknesses of water phantom at 81 kVp, 85 kVp, 90 kVp, 96 kVp, and 102 kVp tube voltage were obtained by using the Phlips diagnost TH X-ray machine, the Hologic DPA/QDR-1 Anthropomorphic Spine Phantom and the self-made water phantom. Exposure dose of different phantom thicknesses under different tube voltage conditions were calculated based on the exposure factor values obtained in the above experiments. The lumbar vertebral phantom was placed in the water phantom, AEC radiography was performed on each grouping condition and the images were stored as a control group. According to the image conditions of the control group, a lower exposure factor level was used to exposure and then save the image as an experimental group. Randomly display lumbar images with the experimental group and the control group on a dual screen in the workstation the images could be distinguished that determine distinguished by 2 radiographers. Perform Cohen's kappa consistency analysis after recording the data. The result showed that AEC is suitable for thickness of 36 cm or more obese patients with a tube voltage of 102 kVp during abdomen radiography examination.
author2 CHEN, CHIA-HUI
author_facet CHEN, CHIA-HUI
HUANG, BO-YEN
黃柏諺
author HUANG, BO-YEN
黃柏諺
spellingShingle HUANG, BO-YEN
黃柏諺
Explore the Application with Automatic Exposure Control Technology in Simulating Different Abdomen Phantom
author_sort HUANG, BO-YEN
title Explore the Application with Automatic Exposure Control Technology in Simulating Different Abdomen Phantom
title_short Explore the Application with Automatic Exposure Control Technology in Simulating Different Abdomen Phantom
title_full Explore the Application with Automatic Exposure Control Technology in Simulating Different Abdomen Phantom
title_fullStr Explore the Application with Automatic Exposure Control Technology in Simulating Different Abdomen Phantom
title_full_unstemmed Explore the Application with Automatic Exposure Control Technology in Simulating Different Abdomen Phantom
title_sort explore the application with automatic exposure control technology in simulating different abdomen phantom
publishDate 2018
url http://ndltd.ncl.edu.tw/handle/9gw3eq
work_keys_str_mv AT huangboyen exploretheapplicationwithautomaticexposurecontroltechnologyinsimulatingdifferentabdomenphantom
AT huángbǎiyàn exploretheapplicationwithautomaticexposurecontroltechnologyinsimulatingdifferentabdomenphantom
AT huangboyen tàntǎozìdòngpùlùkòngzhìjìshùyúmónǐbùtónghòudùfùbùjiǎtǐzhīyīngyòng
AT huángbǎiyàn tàntǎozìdòngpùlùkòngzhìjìshùyúmónǐbùtónghòudùfùbùjiǎtǐzhīyīngyòng
_version_ 1719194844425879552