A Site Investigation Study and Fire Suppression Performance Analysis for Automatic Sprinkler Systems on AS/RS in Taiwan

碩士 === 中央警察大學 === 消防科學研究所 === 106 === With the development of economy in Taiwan, the logistics industry will continue to prosper nowadays and beyond. People tend to have a variety requirement of material. In order to satisfy the supply demand, saving human power and increase the effectiveness of tra...

Full description

Bibliographic Details
Main Authors: Pin-Ping Hsieh, 謝品蘋
Other Authors: Tzu-Sheng Shen
Format: Others
Language:zh-TW
Published: 2018
Online Access:http://ndltd.ncl.edu.tw/handle/73e4hw
id ndltd-TW-106CPU05269001
record_format oai_dc
spelling ndltd-TW-106CPU052690012019-11-28T05:22:00Z http://ndltd.ncl.edu.tw/handle/73e4hw A Site Investigation Study and Fire Suppression Performance Analysis for Automatic Sprinkler Systems on AS/RS in Taiwan 台灣自動化倉儲設置自動撒水設備現況初探與滅火性能之研究 Pin-Ping Hsieh 謝品蘋 碩士 中央警察大學 消防科學研究所 106 With the development of economy in Taiwan, the logistics industry will continue to prosper nowadays and beyond. People tend to have a variety requirement of material. In order to satisfy the supply demand, saving human power and increase the effectiveness of transportation, the introduce of large-scale AS/RS to store commodities in the factories has become a trend. This kind of large-scale AS/RS often exist in many public or private industrial area. The increased density of the stored commodities has the potential of causing a fire. However, merely general specifications were presented in the Standard for Installation of Fire Safety Equipment Based on Use and Occupancy. This study has figure out the warehouse fire scenarios through domestic and foreign regulation comparison and literature review. On the other hand, collecting warehouse fire cases in different places to verify with the above fire characteristic mentioned, moreover, trying to realize why the damage still happened when the Automatic Sprinkler System active confidently. Pick out few representative AS/RS warehouse storages in Taiwan, and investigate their individual sprinkler layout and parameters setting. The comparison within different AS/RS warehouse storages shows the on-site design criteria don’t always coincide with regulations. After on-site investigation, continuing to set up rack-storage model to simulate fire scenario by installing different position of in-rack sprinklers to see the fire extinguishing performance. Finally, with the comparison of regulations and simulation consequences from each warehouse, some conclusions of rack-storage configuration could be made and design options could be provided for AHJ. Tzu-Sheng Shen 沈子勝 2018 學位論文 ; thesis 142 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 中央警察大學 === 消防科學研究所 === 106 === With the development of economy in Taiwan, the logistics industry will continue to prosper nowadays and beyond. People tend to have a variety requirement of material. In order to satisfy the supply demand, saving human power and increase the effectiveness of transportation, the introduce of large-scale AS/RS to store commodities in the factories has become a trend. This kind of large-scale AS/RS often exist in many public or private industrial area. The increased density of the stored commodities has the potential of causing a fire. However, merely general specifications were presented in the Standard for Installation of Fire Safety Equipment Based on Use and Occupancy. This study has figure out the warehouse fire scenarios through domestic and foreign regulation comparison and literature review. On the other hand, collecting warehouse fire cases in different places to verify with the above fire characteristic mentioned, moreover, trying to realize why the damage still happened when the Automatic Sprinkler System active confidently. Pick out few representative AS/RS warehouse storages in Taiwan, and investigate their individual sprinkler layout and parameters setting. The comparison within different AS/RS warehouse storages shows the on-site design criteria don’t always coincide with regulations. After on-site investigation, continuing to set up rack-storage model to simulate fire scenario by installing different position of in-rack sprinklers to see the fire extinguishing performance. Finally, with the comparison of regulations and simulation consequences from each warehouse, some conclusions of rack-storage configuration could be made and design options could be provided for AHJ.
author2 Tzu-Sheng Shen
author_facet Tzu-Sheng Shen
Pin-Ping Hsieh
謝品蘋
author Pin-Ping Hsieh
謝品蘋
spellingShingle Pin-Ping Hsieh
謝品蘋
A Site Investigation Study and Fire Suppression Performance Analysis for Automatic Sprinkler Systems on AS/RS in Taiwan
author_sort Pin-Ping Hsieh
title A Site Investigation Study and Fire Suppression Performance Analysis for Automatic Sprinkler Systems on AS/RS in Taiwan
title_short A Site Investigation Study and Fire Suppression Performance Analysis for Automatic Sprinkler Systems on AS/RS in Taiwan
title_full A Site Investigation Study and Fire Suppression Performance Analysis for Automatic Sprinkler Systems on AS/RS in Taiwan
title_fullStr A Site Investigation Study and Fire Suppression Performance Analysis for Automatic Sprinkler Systems on AS/RS in Taiwan
title_full_unstemmed A Site Investigation Study and Fire Suppression Performance Analysis for Automatic Sprinkler Systems on AS/RS in Taiwan
title_sort site investigation study and fire suppression performance analysis for automatic sprinkler systems on as/rs in taiwan
publishDate 2018
url http://ndltd.ncl.edu.tw/handle/73e4hw
work_keys_str_mv AT pinpinghsieh asiteinvestigationstudyandfiresuppressionperformanceanalysisforautomaticsprinklersystemsonasrsintaiwan
AT xièpǐnpíng asiteinvestigationstudyandfiresuppressionperformanceanalysisforautomaticsprinklersystemsonasrsintaiwan
AT pinpinghsieh táiwānzìdònghuàcāngchǔshèzhìzìdòngsāshuǐshèbèixiànkuàngchūtànyǔmièhuǒxìngnéngzhīyánjiū
AT xièpǐnpíng táiwānzìdònghuàcāngchǔshèzhìzìdòngsāshuǐshèbèixiànkuàngchūtànyǔmièhuǒxìngnéngzhīyánjiū
AT pinpinghsieh siteinvestigationstudyandfiresuppressionperformanceanalysisforautomaticsprinklersystemsonasrsintaiwan
AT xièpǐnpíng siteinvestigationstudyandfiresuppressionperformanceanalysisforautomaticsprinklersystemsonasrsintaiwan
_version_ 1719296910814085120