Study on the optimization of dual transparent diffraction grating combination for the in-plane displacement measurement

碩士 === 元智大學 === 光電工程學系 === 105 === In this study, the optimal dual gratings combination was proposed and demonstrated that the high sensitivity, high resolution and low displacement error can be achieved by adopting the combination of the grating scales of 1.6 μm and 1.2 μm, respectively. The experi...

Full description

Bibliographic Details
Main Authors: Po-Tsen Meng 孟柏辰, 孟柏辰
Other Authors: Cheng-Chin Hsu
Format: Others
Language:zh-TW
Published: 2017
Online Access:http://ndltd.ncl.edu.tw/handle/89155659292379850107
id ndltd-TW-105YZU05614014
record_format oai_dc
spelling ndltd-TW-105YZU056140142017-09-19T04:29:40Z http://ndltd.ncl.edu.tw/handle/89155659292379850107 Study on the optimization of dual transparent diffraction grating combination for the in-plane displacement measurement 雙穿透式繞射光柵於面內位移量測之研究 Po-Tsen Meng 孟柏辰 孟柏辰 碩士 元智大學 光電工程學系 105 In this study, the optimal dual gratings combination was proposed and demonstrated that the high sensitivity, high resolution and low displacement error can be achieved by adopting the combination of the grating scales of 1.6 μm and 1.2 μm, respectively. The experiment results showed that the displacement difference between comparison method (HP interferometer) and proposed method were within 0.36% and 0.7% for the travel ranges of 40 μm and 0.5μm, respectively. The displacement error of the optimal combination of dual gratings was within 5.37 nm as the measured phase of 360°. Cheng-Chin Hsu 許正治 2017 學位論文 ; thesis 80 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 元智大學 === 光電工程學系 === 105 === In this study, the optimal dual gratings combination was proposed and demonstrated that the high sensitivity, high resolution and low displacement error can be achieved by adopting the combination of the grating scales of 1.6 μm and 1.2 μm, respectively. The experiment results showed that the displacement difference between comparison method (HP interferometer) and proposed method were within 0.36% and 0.7% for the travel ranges of 40 μm and 0.5μm, respectively. The displacement error of the optimal combination of dual gratings was within 5.37 nm as the measured phase of 360°.
author2 Cheng-Chin Hsu
author_facet Cheng-Chin Hsu
Po-Tsen Meng 孟柏辰
孟柏辰
author Po-Tsen Meng 孟柏辰
孟柏辰
spellingShingle Po-Tsen Meng 孟柏辰
孟柏辰
Study on the optimization of dual transparent diffraction grating combination for the in-plane displacement measurement
author_sort Po-Tsen Meng 孟柏辰
title Study on the optimization of dual transparent diffraction grating combination for the in-plane displacement measurement
title_short Study on the optimization of dual transparent diffraction grating combination for the in-plane displacement measurement
title_full Study on the optimization of dual transparent diffraction grating combination for the in-plane displacement measurement
title_fullStr Study on the optimization of dual transparent diffraction grating combination for the in-plane displacement measurement
title_full_unstemmed Study on the optimization of dual transparent diffraction grating combination for the in-plane displacement measurement
title_sort study on the optimization of dual transparent diffraction grating combination for the in-plane displacement measurement
publishDate 2017
url http://ndltd.ncl.edu.tw/handle/89155659292379850107
work_keys_str_mv AT potsenmengmèngbǎichén studyontheoptimizationofdualtransparentdiffractiongratingcombinationfortheinplanedisplacementmeasurement
AT mèngbǎichén studyontheoptimizationofdualtransparentdiffractiongratingcombinationfortheinplanedisplacementmeasurement
AT potsenmengmèngbǎichén shuāngchuāntòushìràoshèguāngshānyúmiànnèiwèiyíliàngcèzhīyánjiū
AT mèngbǎichén shuāngchuāntòushìràoshèguāngshānyúmiànnèiwèiyíliàngcèzhīyánjiū
_version_ 1718538405293326336