Study on the Effectiveness of Smoke Evacuation System for Elderly Health Care Units -LOHAS Fire Case

碩士 === 吳鳳科技大學 === 消防研究所 === 105 === This study explored whether the fire in the space of the elderly welfare institutions is growing or declining, which is a proportional function between the surface area of the fire and the amount of oxygen. Based on the CFAST simulation results, when the mechanica...

Full description

Bibliographic Details
Main Authors: Li Qing-xiang, 李慶祥
Other Authors: Lu Sohu-chien
Format: Others
Language:zh-TW
Published: 2017
Online Access:http://ndltd.ncl.edu.tw/handle/rksr7v
id ndltd-TW-105WFIT0269008
record_format oai_dc
spelling ndltd-TW-105WFIT02690082019-05-15T23:24:50Z http://ndltd.ncl.edu.tw/handle/rksr7v Study on the Effectiveness of Smoke Evacuation System for Elderly Health Care Units -LOHAS Fire Case 老人安養機構排煙避難有效性之研究-以樂活老人照顧中心火災為例 Li Qing-xiang 李慶祥 碩士 吳鳳科技大學 消防研究所 105 This study explored whether the fire in the space of the elderly welfare institutions is growing or declining, which is a proportional function between the surface area of the fire and the amount of oxygen. Based on the CFAST simulation results, when the mechanical smoke discharge was carried out under the full door open, the thermal laminar temperature in zoning space of fire room was quite high, while there was not much difference of thermal laminar in each temperature layer. However, the thermal laminar temperature in place installed with mechanical smoke extraction equipment was higher than that of the place without such equipment. According to the results of the fire test, when the mechanical smoke extraction was carried out in the condition of full outlet opening, the temperature variation between the sites of experimental model house near the fire source and smoke extraction port showed a significant growth. Both results verified the functional relationship between the combustion amount of fire load and oxygen in zoning space. Thus, when the fire of zoning space was combusted under ventilation control and the mechanical smoke extraction was initiated, the fire burning would be more prosperous due to the oxygen input. The installation of mechanical smoke extraction equipment in the elderly institutions must be under the condition of complete anti-smoke zoning (all openings are closed) so as to improve the fatal toxic gas. Yet, its effect is still not as effective as the refuge strategy of door closing, which is more cost-effective. Lu Sohu-chien Chen Yong-long Lu Tian-yuan 盧守謙 陳永隆 盧添源 2017 學位論文 ; thesis 67 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 吳鳳科技大學 === 消防研究所 === 105 === This study explored whether the fire in the space of the elderly welfare institutions is growing or declining, which is a proportional function between the surface area of the fire and the amount of oxygen. Based on the CFAST simulation results, when the mechanical smoke discharge was carried out under the full door open, the thermal laminar temperature in zoning space of fire room was quite high, while there was not much difference of thermal laminar in each temperature layer. However, the thermal laminar temperature in place installed with mechanical smoke extraction equipment was higher than that of the place without such equipment. According to the results of the fire test, when the mechanical smoke extraction was carried out in the condition of full outlet opening, the temperature variation between the sites of experimental model house near the fire source and smoke extraction port showed a significant growth. Both results verified the functional relationship between the combustion amount of fire load and oxygen in zoning space. Thus, when the fire of zoning space was combusted under ventilation control and the mechanical smoke extraction was initiated, the fire burning would be more prosperous due to the oxygen input. The installation of mechanical smoke extraction equipment in the elderly institutions must be under the condition of complete anti-smoke zoning (all openings are closed) so as to improve the fatal toxic gas. Yet, its effect is still not as effective as the refuge strategy of door closing, which is more cost-effective.
author2 Lu Sohu-chien
author_facet Lu Sohu-chien
Li Qing-xiang
李慶祥
author Li Qing-xiang
李慶祥
spellingShingle Li Qing-xiang
李慶祥
Study on the Effectiveness of Smoke Evacuation System for Elderly Health Care Units -LOHAS Fire Case
author_sort Li Qing-xiang
title Study on the Effectiveness of Smoke Evacuation System for Elderly Health Care Units -LOHAS Fire Case
title_short Study on the Effectiveness of Smoke Evacuation System for Elderly Health Care Units -LOHAS Fire Case
title_full Study on the Effectiveness of Smoke Evacuation System for Elderly Health Care Units -LOHAS Fire Case
title_fullStr Study on the Effectiveness of Smoke Evacuation System for Elderly Health Care Units -LOHAS Fire Case
title_full_unstemmed Study on the Effectiveness of Smoke Evacuation System for Elderly Health Care Units -LOHAS Fire Case
title_sort study on the effectiveness of smoke evacuation system for elderly health care units -lohas fire case
publishDate 2017
url http://ndltd.ncl.edu.tw/handle/rksr7v
work_keys_str_mv AT liqingxiang studyontheeffectivenessofsmokeevacuationsystemforelderlyhealthcareunitslohasfirecase
AT lǐqìngxiáng studyontheeffectivenessofsmokeevacuationsystemforelderlyhealthcareunitslohasfirecase
AT liqingxiang lǎorénānyǎngjīgòupáiyānbìnányǒuxiàoxìngzhīyánjiūyǐlèhuólǎorénzhàogùzhōngxīnhuǒzāiwèilì
AT lǐqìngxiáng lǎorénānyǎngjīgòupáiyānbìnányǒuxiàoxìngzhīyánjiūyǐlèhuólǎorénzhàogùzhōngxīnhuǒzāiwèilì
_version_ 1719147602678644736