Designs of Power Dividers Using Defected Ground Structure π- and T-Shaped Transformers
碩士 === 國立高雄大學 === 電機工程學系碩博士班 === 105 === This thesis proposes three equal modified Wilkinson power dividers and one unequal modified Wilkinson power divider. In general, each quarter-wavelength impedance transformer of conventional Wilkinson power divider can be replaced by T- or π-shaped transmissi...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
2017
|
Online Access: | http://ndltd.ncl.edu.tw/handle/3h6whf |
id |
ndltd-TW-105NUK00442020 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-105NUK004420202019-05-15T23:31:51Z http://ndltd.ncl.edu.tw/handle/3h6whf Designs of Power Dividers Using Defected Ground Structure π- and T-Shaped Transformers 利用缺陷地結構π型與T型轉換器之功率分配器設計 Zong-Shiann Tsai 蔡宗憲 碩士 國立高雄大學 電機工程學系碩博士班 105 This thesis proposes three equal modified Wilkinson power dividers and one unequal modified Wilkinson power divider. In general, each quarter-wavelength impedance transformer of conventional Wilkinson power divider can be replaced by T- or π-shaped transmission line transformer. To achieve short length of each series transmission line, high characteristic impedance may be needed. However, high impedance line is usually difficult to be realized in microstrip line form. To relax the realization problem of high impedance line, the proposed dividers use T- or π-shaped defected ground structure transformers to reach impedance match and isolation requirement. Pu-Hua Deng 鄧卜華 2017 學位論文 ; thesis 58 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 國立高雄大學 === 電機工程學系碩博士班 === 105 === This thesis proposes three equal modified Wilkinson power dividers and one unequal modified Wilkinson power divider. In general, each quarter-wavelength impedance transformer of conventional Wilkinson power divider can be replaced by T- or π-shaped transmission line transformer. To achieve short length of each series transmission line, high characteristic impedance may be needed. However, high impedance line is usually difficult to be realized in microstrip line form. To relax the realization problem of high impedance line, the proposed dividers use T- or π-shaped defected ground structure transformers to reach impedance match and isolation requirement.
|
author2 |
Pu-Hua Deng |
author_facet |
Pu-Hua Deng Zong-Shiann Tsai 蔡宗憲 |
author |
Zong-Shiann Tsai 蔡宗憲 |
spellingShingle |
Zong-Shiann Tsai 蔡宗憲 Designs of Power Dividers Using Defected Ground Structure π- and T-Shaped Transformers |
author_sort |
Zong-Shiann Tsai |
title |
Designs of Power Dividers Using Defected Ground Structure π- and T-Shaped Transformers |
title_short |
Designs of Power Dividers Using Defected Ground Structure π- and T-Shaped Transformers |
title_full |
Designs of Power Dividers Using Defected Ground Structure π- and T-Shaped Transformers |
title_fullStr |
Designs of Power Dividers Using Defected Ground Structure π- and T-Shaped Transformers |
title_full_unstemmed |
Designs of Power Dividers Using Defected Ground Structure π- and T-Shaped Transformers |
title_sort |
designs of power dividers using defected ground structure π- and t-shaped transformers |
publishDate |
2017 |
url |
http://ndltd.ncl.edu.tw/handle/3h6whf |
work_keys_str_mv |
AT zongshianntsai designsofpowerdividersusingdefectedgroundstructurepandtshapedtransformers AT càizōngxiàn designsofpowerdividersusingdefectedgroundstructurepandtshapedtransformers AT zongshianntsai lìyòngquēxiàndejiégòupxíngyǔtxíngzhuǎnhuànqìzhīgōnglǜfēnpèiqìshèjì AT càizōngxiàn lìyòngquēxiàndejiégòupxíngyǔtxíngzhuǎnhuànqìzhīgōnglǜfēnpèiqìshèjì |
_version_ |
1719148312318181376 |