A Study on Fire Safety Evaluation of High-rise Residential Units

碩士 === 國立臺灣科技大學 === 建築系 === 105 === Through these past cases review, both the interior designers and the customers could get better ideas, regarding the Plan of Performance-based Design of Fire Safety and Evacuation in Buildings, about the content, the verification, and the documentary review. By kn...

Full description

Bibliographic Details
Main Authors: Hao-Lin Hsu, 徐皓霖
Other Authors: Ching-Yuan Lin
Format: Others
Language:zh-TW
Published: 2017
Online Access:http://ndltd.ncl.edu.tw/handle/rz872h
id ndltd-TW-105NTUS5222045
record_format oai_dc
spelling ndltd-TW-105NTUS52220452019-05-15T23:46:35Z http://ndltd.ncl.edu.tw/handle/rz872h A Study on Fire Safety Evaluation of High-rise Residential Units 高層集合住宅單元防火避難安全驗證案例之探討 Hao-Lin Hsu 徐皓霖 碩士 國立臺灣科技大學 建築系 105 Through these past cases review, both the interior designers and the customers could get better ideas, regarding the Plan of Performance-based Design of Fire Safety and Evacuation in Buildings, about the content, the verification, and the documentary review. By knowing the requlations, both of them could create their design not only to compliance with the safety requirements but to fulfill the customized needs efficiently and economically. It's an all-win situation for the designers, the customers, and the conformity assessment institutions. Through the data collecting and compaction of the past documentary reviews, based on the laws and regulations, and the Building Fire Evacuation Safety Performance Verification of Technical Manuals, we made a chart to reveal the actual infuences of partition walls to the evacuation distance. We compared the caculationfomular with the data from the passed reviews to find out the difference comparison. The analization shows that the partition walls will cost more evacuation time up to 10%. Overall, using better finishing materials, shortening the walking evacuation distance, and raise the height of the ceiling could improve the level of the fire safety and evacuation in buildings. Through the simple determination of the proportion of the safety slack ratio of the design, it is possible to simplify the application for the use of the license phase to apply for the assessment of the operation process and the reduction of the review meeting to achieve the purpose of saving time and cost.It can reduce the costs 20~94% per case each time. Ching-Yuan Lin 林慶元 2017 學位論文 ; thesis 114 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立臺灣科技大學 === 建築系 === 105 === Through these past cases review, both the interior designers and the customers could get better ideas, regarding the Plan of Performance-based Design of Fire Safety and Evacuation in Buildings, about the content, the verification, and the documentary review. By knowing the requlations, both of them could create their design not only to compliance with the safety requirements but to fulfill the customized needs efficiently and economically. It's an all-win situation for the designers, the customers, and the conformity assessment institutions. Through the data collecting and compaction of the past documentary reviews, based on the laws and regulations, and the Building Fire Evacuation Safety Performance Verification of Technical Manuals, we made a chart to reveal the actual infuences of partition walls to the evacuation distance. We compared the caculationfomular with the data from the passed reviews to find out the difference comparison. The analization shows that the partition walls will cost more evacuation time up to 10%. Overall, using better finishing materials, shortening the walking evacuation distance, and raise the height of the ceiling could improve the level of the fire safety and evacuation in buildings. Through the simple determination of the proportion of the safety slack ratio of the design, it is possible to simplify the application for the use of the license phase to apply for the assessment of the operation process and the reduction of the review meeting to achieve the purpose of saving time and cost.It can reduce the costs 20~94% per case each time.
author2 Ching-Yuan Lin
author_facet Ching-Yuan Lin
Hao-Lin Hsu
徐皓霖
author Hao-Lin Hsu
徐皓霖
spellingShingle Hao-Lin Hsu
徐皓霖
A Study on Fire Safety Evaluation of High-rise Residential Units
author_sort Hao-Lin Hsu
title A Study on Fire Safety Evaluation of High-rise Residential Units
title_short A Study on Fire Safety Evaluation of High-rise Residential Units
title_full A Study on Fire Safety Evaluation of High-rise Residential Units
title_fullStr A Study on Fire Safety Evaluation of High-rise Residential Units
title_full_unstemmed A Study on Fire Safety Evaluation of High-rise Residential Units
title_sort study on fire safety evaluation of high-rise residential units
publishDate 2017
url http://ndltd.ncl.edu.tw/handle/rz872h
work_keys_str_mv AT haolinhsu astudyonfiresafetyevaluationofhighriseresidentialunits
AT xúhàolín astudyonfiresafetyevaluationofhighriseresidentialunits
AT haolinhsu gāocéngjíhézhùzháidānyuánfánghuǒbìnánānquányànzhèngànlìzhītàntǎo
AT xúhàolín gāocéngjíhézhùzháidānyuánfánghuǒbìnánānquányànzhèngànlìzhītàntǎo
AT haolinhsu studyonfiresafetyevaluationofhighriseresidentialunits
AT xúhàolín studyonfiresafetyevaluationofhighriseresidentialunits
_version_ 1719152915745079296