Study on energy saving of chilled water main unit by inverter converter

碩士 === 國立屏東科技大學 === 機械工程系所 === 105 === In the industrial plant ice water system (Chiller, CHP, CDP, Cooling Tower) are power consumption equipment, and its power consumption ratio of the entire plant power consumption of the top three, ice water system design is different Of the planning choice, the...

Full description

Bibliographic Details
Main Authors: Yen, Chih Lin, 顏志霖
Other Authors: Teoh, Lay Gaik
Format: Others
Language:zh-TW
Published: 2017
Online Access:http://ndltd.ncl.edu.tw/handle/twe65y
id ndltd-TW-105NPUS5489008
record_format oai_dc
spelling ndltd-TW-105NPUS54890082019-05-16T00:00:24Z http://ndltd.ncl.edu.tw/handle/twe65y Study on energy saving of chilled water main unit by inverter converter 變頻器控制冰水主機一次流量節能研究 Yen, Chih Lin 顏志霖 碩士 國立屏東科技大學 機械工程系所 105 In the industrial plant ice water system (Chiller, CHP, CDP, Cooling Tower) are power consumption equipment, and its power consumption ratio of the entire plant power consumption of the top three, ice water system design is different Of the planning choice, the first side of the ice water conditioning system is the concept of Trane in 1999, has been widely used in Europe and the United States, but in recent years in the country to get rid of the concept of stereotypes, the use of cases increased year by year. This study is aimed at the impact of power consumption on the primary side of the ice water system in the industrial plant. The most direct is the reduction of the power consumption of the ice water pump and the cooling water pump, but also the evaporation and condensation temperature for the ice water host, Changing the temperature difference between the water temperature and the evaporative temperature of the ice water will also affect the heat transfer of the evaporator, and it will also affect the performance coefficient of the ice water. The purpose of this study is to analyze the effect of the variable flow on the data, Best operating mode. The design of the primary side of the variable flow, so that the pump has more time in low water and low power consumption. Because the pump power consumption and the traffic is proportional to the characteristics of the third, so reduce the amount of water when there are often large energy efficiency, outside the wet bulb temperature lower energy efficiency is higher, so the effect of winter is particularly significant. Teoh, Lay Gaik 張莉毓 2017 學位論文 ; thesis 44 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立屏東科技大學 === 機械工程系所 === 105 === In the industrial plant ice water system (Chiller, CHP, CDP, Cooling Tower) are power consumption equipment, and its power consumption ratio of the entire plant power consumption of the top three, ice water system design is different Of the planning choice, the first side of the ice water conditioning system is the concept of Trane in 1999, has been widely used in Europe and the United States, but in recent years in the country to get rid of the concept of stereotypes, the use of cases increased year by year. This study is aimed at the impact of power consumption on the primary side of the ice water system in the industrial plant. The most direct is the reduction of the power consumption of the ice water pump and the cooling water pump, but also the evaporation and condensation temperature for the ice water host, Changing the temperature difference between the water temperature and the evaporative temperature of the ice water will also affect the heat transfer of the evaporator, and it will also affect the performance coefficient of the ice water. The purpose of this study is to analyze the effect of the variable flow on the data, Best operating mode. The design of the primary side of the variable flow, so that the pump has more time in low water and low power consumption. Because the pump power consumption and the traffic is proportional to the characteristics of the third, so reduce the amount of water when there are often large energy efficiency, outside the wet bulb temperature lower energy efficiency is higher, so the effect of winter is particularly significant.
author2 Teoh, Lay Gaik
author_facet Teoh, Lay Gaik
Yen, Chih Lin
顏志霖
author Yen, Chih Lin
顏志霖
spellingShingle Yen, Chih Lin
顏志霖
Study on energy saving of chilled water main unit by inverter converter
author_sort Yen, Chih Lin
title Study on energy saving of chilled water main unit by inverter converter
title_short Study on energy saving of chilled water main unit by inverter converter
title_full Study on energy saving of chilled water main unit by inverter converter
title_fullStr Study on energy saving of chilled water main unit by inverter converter
title_full_unstemmed Study on energy saving of chilled water main unit by inverter converter
title_sort study on energy saving of chilled water main unit by inverter converter
publishDate 2017
url http://ndltd.ncl.edu.tw/handle/twe65y
work_keys_str_mv AT yenchihlin studyonenergysavingofchilledwatermainunitbyinverterconverter
AT yánzhìlín studyonenergysavingofchilledwatermainunitbyinverterconverter
AT yenchihlin biànpínqìkòngzhìbīngshuǐzhǔjīyīcìliúliàngjiénéngyánjiū
AT yánzhìlín biànpínqìkòngzhìbīngshuǐzhǔjīyīcìliúliàngjiénéngyánjiū
_version_ 1719158463186075648