The Subjective and Objective Assessments of Open Fitting Hearing Aids with Custom Tips

碩士 === 國立高雄師範大學 === 特殊教育學系 === 105 === The purpose of the research was to investigate the difference between Custom tip and Dome on occlusion, gain, the function of signal processing, and satisfaction when fitting open-fit hearing aids. The experiment research method was adopted. According to differ...

Full description

Bibliographic Details
Main Authors: CHEN, CHI-HONG, 陳紀宏
Other Authors: CHEN, HSIAO-CHUAN
Format: Others
Language:zh-TW
Published: 2017
Online Access:http://ndltd.ncl.edu.tw/handle/83vhfp
id ndltd-TW-105NKNU0284028
record_format oai_dc
spelling ndltd-TW-105NKNU02840282019-05-15T23:32:18Z http://ndltd.ncl.edu.tw/handle/83vhfp The Subjective and Objective Assessments of Open Fitting Hearing Aids with Custom Tips 開放式助聽器搭配客製化耳塞型耳模之效益評估 CHEN, CHI-HONG 陳紀宏 碩士 國立高雄師範大學 特殊教育學系 105 The purpose of the research was to investigate the difference between Custom tip and Dome on occlusion, gain, the function of signal processing, and satisfaction when fitting open-fit hearing aids. The experiment research method was adopted. According to different research goals, there were four experiments. The samples and results were described as follows: 1、 The occlusion and occlusion effect was evaluated via objective and subjective methods. On the part of objective method was Real Ear Measurement(REM). The results included:(1) Dome was significantly smaller than Custom tip on REOR-REUR(OU) and REAR-REUR(AU) when the input sound level was 50 dB SPL,(2) When the input sound level was 65 dB SPL, Dome’s OU was significantly smaller than Custom tip’s at 750Hz and 1000Hz. There was no significantly difference between Custom tip and Dome on AU. On the part of subjective method was Q8 and Q9 of the open fitting hearing aids’ satisfaction inventory. The result shows there were no significantly difference between Custom tip and Dome on these two questions. But the Custom tip was same as Dome(48%) on the occasion effect, even better(37%). 2、 The REIG and functional gain did not differ between Custom tip and Dome, regardless of whether 50 dB SPL or 65 dB SPL input sound level were used. Both REIG and functional gain were significantly different within different frequencies(p<.001). 3、 SRT on quiet condition(M=29.81) was significantly better than noise conditions(M=32.67)(p<.01). Using Custom tip(M=30.58) also could achieve better SRT than using Dome(M=31.89)(p<.001). There were no significantly differenct on microphone setting, noise reduction, and the interaction within variables 4、Two methods were used to compare the usage of Custom tip and Dome via the open fitting hearing aids’ satisfaction inventory. There was no significantly difference between Custom tip and Dome on overall subjective rating. However, choosing one of the following solutions set Dome, Custom tip or Same in each questions of the inventory, both the option of Same and Custom tip were significantly more than the option of Dome(p<.01). The recommend about research and clinical field also mentioned in the thesis. CHEN, HSIAO-CHUAN 陳小娟 2017 學位論文 ; thesis 116 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立高雄師範大學 === 特殊教育學系 === 105 === The purpose of the research was to investigate the difference between Custom tip and Dome on occlusion, gain, the function of signal processing, and satisfaction when fitting open-fit hearing aids. The experiment research method was adopted. According to different research goals, there were four experiments. The samples and results were described as follows: 1、 The occlusion and occlusion effect was evaluated via objective and subjective methods. On the part of objective method was Real Ear Measurement(REM). The results included:(1) Dome was significantly smaller than Custom tip on REOR-REUR(OU) and REAR-REUR(AU) when the input sound level was 50 dB SPL,(2) When the input sound level was 65 dB SPL, Dome’s OU was significantly smaller than Custom tip’s at 750Hz and 1000Hz. There was no significantly difference between Custom tip and Dome on AU. On the part of subjective method was Q8 and Q9 of the open fitting hearing aids’ satisfaction inventory. The result shows there were no significantly difference between Custom tip and Dome on these two questions. But the Custom tip was same as Dome(48%) on the occasion effect, even better(37%). 2、 The REIG and functional gain did not differ between Custom tip and Dome, regardless of whether 50 dB SPL or 65 dB SPL input sound level were used. Both REIG and functional gain were significantly different within different frequencies(p<.001). 3、 SRT on quiet condition(M=29.81) was significantly better than noise conditions(M=32.67)(p<.01). Using Custom tip(M=30.58) also could achieve better SRT than using Dome(M=31.89)(p<.001). There were no significantly differenct on microphone setting, noise reduction, and the interaction within variables 4、Two methods were used to compare the usage of Custom tip and Dome via the open fitting hearing aids’ satisfaction inventory. There was no significantly difference between Custom tip and Dome on overall subjective rating. However, choosing one of the following solutions set Dome, Custom tip or Same in each questions of the inventory, both the option of Same and Custom tip were significantly more than the option of Dome(p<.01). The recommend about research and clinical field also mentioned in the thesis.
author2 CHEN, HSIAO-CHUAN
author_facet CHEN, HSIAO-CHUAN
CHEN, CHI-HONG
陳紀宏
author CHEN, CHI-HONG
陳紀宏
spellingShingle CHEN, CHI-HONG
陳紀宏
The Subjective and Objective Assessments of Open Fitting Hearing Aids with Custom Tips
author_sort CHEN, CHI-HONG
title The Subjective and Objective Assessments of Open Fitting Hearing Aids with Custom Tips
title_short The Subjective and Objective Assessments of Open Fitting Hearing Aids with Custom Tips
title_full The Subjective and Objective Assessments of Open Fitting Hearing Aids with Custom Tips
title_fullStr The Subjective and Objective Assessments of Open Fitting Hearing Aids with Custom Tips
title_full_unstemmed The Subjective and Objective Assessments of Open Fitting Hearing Aids with Custom Tips
title_sort subjective and objective assessments of open fitting hearing aids with custom tips
publishDate 2017
url http://ndltd.ncl.edu.tw/handle/83vhfp
work_keys_str_mv AT chenchihong thesubjectiveandobjectiveassessmentsofopenfittinghearingaidswithcustomtips
AT chénjìhóng thesubjectiveandobjectiveassessmentsofopenfittinghearingaidswithcustomtips
AT chenchihong kāifàngshìzhùtīngqìdāpèikèzhìhuàěrsāixíngěrmózhīxiàoyìpínggū
AT chénjìhóng kāifàngshìzhùtīngqìdāpèikèzhìhuàěrsāixíngěrmózhīxiàoyìpínggū
AT chenchihong subjectiveandobjectiveassessmentsofopenfittinghearingaidswithcustomtips
AT chénjìhóng subjectiveandobjectiveassessmentsofopenfittinghearingaidswithcustomtips
_version_ 1719149672057012224