Implementation of AC/DC Power Factor Correction for Synchronous Generator

碩士 === 國立彰化師範大學 === 電機工程學系 === 105 === This thesis develops a “Implementation of AC/DC Power Factor Correction”. It is composed of a three-phase power factor corrector, three sets of voltage detection circuits and dsPIC30F4011 microcontrollers. It can realize the function of the generator power fact...

Full description

Bibliographic Details
Main Authors: Lyu,Guan-LIn, 呂冠霖
Other Authors: Chen,Liang-Rui
Format: Others
Language:zh-TW
Published: 2017
Online Access:http://ndltd.ncl.edu.tw/handle/z9s658
id ndltd-TW-105NCUE5442063
record_format oai_dc
spelling ndltd-TW-105NCUE54420632019-05-16T00:15:44Z http://ndltd.ncl.edu.tw/handle/z9s658 Implementation of AC/DC Power Factor Correction for Synchronous Generator 應用於同步發電機之交流/直流功率因數修正器 Lyu,Guan-LIn 呂冠霖 碩士 國立彰化師範大學 電機工程學系 105 This thesis develops a “Implementation of AC/DC Power Factor Correction”. It is composed of a three-phase power factor corrector, three sets of voltage detection circuits and dsPIC30F4011 microcontrollers. It can realize the function of the generator power factor correction. Three-phase power factor corrector uses a full-controlled AC/DC converter with a Coordinate axis conversion controller. The power and virtual work control method of the input voltage and current to achieve the purpose of the same phase. Finally, a 1kW of the prototype is designed and implemented to verify the feasibility of the proposed system. The experimental results show that the proposed generator three-phase AC/DC power factor correction can indeed achieve the effect of power factor correction. Chen,Liang-Rui Yang,Wen-Ran 陳良瑞 楊文然 2017 學位論文 ; thesis 49 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立彰化師範大學 === 電機工程學系 === 105 === This thesis develops a “Implementation of AC/DC Power Factor Correction”. It is composed of a three-phase power factor corrector, three sets of voltage detection circuits and dsPIC30F4011 microcontrollers. It can realize the function of the generator power factor correction. Three-phase power factor corrector uses a full-controlled AC/DC converter with a Coordinate axis conversion controller. The power and virtual work control method of the input voltage and current to achieve the purpose of the same phase. Finally, a 1kW of the prototype is designed and implemented to verify the feasibility of the proposed system. The experimental results show that the proposed generator three-phase AC/DC power factor correction can indeed achieve the effect of power factor correction.
author2 Chen,Liang-Rui
author_facet Chen,Liang-Rui
Lyu,Guan-LIn
呂冠霖
author Lyu,Guan-LIn
呂冠霖
spellingShingle Lyu,Guan-LIn
呂冠霖
Implementation of AC/DC Power Factor Correction for Synchronous Generator
author_sort Lyu,Guan-LIn
title Implementation of AC/DC Power Factor Correction for Synchronous Generator
title_short Implementation of AC/DC Power Factor Correction for Synchronous Generator
title_full Implementation of AC/DC Power Factor Correction for Synchronous Generator
title_fullStr Implementation of AC/DC Power Factor Correction for Synchronous Generator
title_full_unstemmed Implementation of AC/DC Power Factor Correction for Synchronous Generator
title_sort implementation of ac/dc power factor correction for synchronous generator
publishDate 2017
url http://ndltd.ncl.edu.tw/handle/z9s658
work_keys_str_mv AT lyuguanlin implementationofacdcpowerfactorcorrectionforsynchronousgenerator
AT lǚguānlín implementationofacdcpowerfactorcorrectionforsynchronousgenerator
AT lyuguanlin yīngyòngyútóngbùfādiànjīzhījiāoliúzhíliúgōnglǜyīnshùxiūzhèngqì
AT lǚguānlín yīngyòngyútóngbùfādiànjīzhījiāoliúzhíliúgōnglǜyīnshùxiūzhèngqì
_version_ 1719163527054229504