Calibration method of the Inclinometer and in-situ verification
碩士 === 國立中興大學 === 土木工程學系所 === 105 === In this thesis, the calibration of inclinometers was performed by using the self-developed frame based on the geometric principles. The calibration frame is capable of measuring a tiny change in vertical angle with an accuracy of 0.000143 degree. Firstly, the st...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
2017
|
Online Access: | http://ndltd.ncl.edu.tw/handle/51653625793398037560 |
id |
ndltd-TW-105NCHU5015088 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-105NCHU50150882017-11-12T04:39:01Z http://ndltd.ncl.edu.tw/handle/51653625793398037560 Calibration method of the Inclinometer and in-situ verification 傾斜儀之校正方法與現地量測驗證 Yunjan Chan 詹昀燃 碩士 國立中興大學 土木工程學系所 105 In this thesis, the calibration of inclinometers was performed by using the self-developed frame based on the geometric principles. The calibration frame is capable of measuring a tiny change in vertical angle with an accuracy of 0.000143 degree. Firstly, the study carried out the calibration of inclinometers with the calibration frame in the laboratory. The calibration factor of each inclinometer was obtained through the calibration process. Secondly, field measurement on a 20-m deep inclinometer casing was performed to investigate the feasibility of using the calibration factor to correct the measurement readings. The results obtained from the study show that very consistent results were found for two different inclinometers after the measurement readings were corrected by multiplying the calibration factor. 林宜清 2017 學位論文 ; thesis 46 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 國立中興大學 === 土木工程學系所 === 105 === In this thesis, the calibration of inclinometers was performed by using the self-developed frame based on the geometric principles. The calibration frame is capable of measuring a tiny change in vertical angle with an accuracy of 0.000143 degree. Firstly, the study carried out the calibration of inclinometers with the calibration frame in the laboratory. The calibration factor of each inclinometer was obtained through the calibration process. Secondly, field measurement on a 20-m deep inclinometer casing was performed to investigate the feasibility of using the calibration factor to correct the measurement readings. The results obtained from the study show that very consistent results were found for two different inclinometers after the measurement readings were corrected by multiplying the calibration factor.
|
author2 |
林宜清 |
author_facet |
林宜清 Yunjan Chan 詹昀燃 |
author |
Yunjan Chan 詹昀燃 |
spellingShingle |
Yunjan Chan 詹昀燃 Calibration method of the Inclinometer and in-situ verification |
author_sort |
Yunjan Chan |
title |
Calibration method of the Inclinometer and in-situ verification |
title_short |
Calibration method of the Inclinometer and in-situ verification |
title_full |
Calibration method of the Inclinometer and in-situ verification |
title_fullStr |
Calibration method of the Inclinometer and in-situ verification |
title_full_unstemmed |
Calibration method of the Inclinometer and in-situ verification |
title_sort |
calibration method of the inclinometer and in-situ verification |
publishDate |
2017 |
url |
http://ndltd.ncl.edu.tw/handle/51653625793398037560 |
work_keys_str_mv |
AT yunjanchan calibrationmethodoftheinclinometerandinsituverification AT zhānyúnrán calibrationmethodoftheinclinometerandinsituverification AT yunjanchan qīngxiéyízhīxiàozhèngfāngfǎyǔxiàndeliàngcèyànzhèng AT zhānyúnrán qīngxiéyízhīxiàozhèngfāngfǎyǔxiàndeliàngcèyànzhèng |
_version_ |
1718561461951791104 |