Analysis of Indoor Air Quality at the Library in Dayeh University

碩士 === 大葉大學 === 環境工程學系碩士班 === 105 === Poor indoor air quality has been shown to have adverse effects on human health. This study investigated the indoor air quality of library. The multi-channel air quality monitor was used to monitor VOC, CO, CO2, O3, HCHO, temperature and humidity. While Turnkey O...

Full description

Bibliographic Details
Main Authors: YANG YAO-CHUN, 楊曜駿
Other Authors: YE CI-HUEI
Format: Others
Language:zh-TW
Published: 2016
Online Access:http://ndltd.ncl.edu.tw/handle/07155794771351412331
id ndltd-TW-105DYU00515003
record_format oai_dc
spelling ndltd-TW-105DYU005150032017-03-30T04:33:54Z http://ndltd.ncl.edu.tw/handle/07155794771351412331 Analysis of Indoor Air Quality at the Library in Dayeh University 大葉大學圖書館室內空氣品質分析 YANG YAO-CHUN 楊曜駿 碩士 大葉大學 環境工程學系碩士班 105 Poor indoor air quality has been shown to have adverse effects on human health. This study investigated the indoor air quality of library. The multi-channel air quality monitor was used to monitor VOC, CO, CO2, O3, HCHO, temperature and humidity. While Turnkey Osiris, a digital suspended particulate monitor, measured TSP, PM1, PM2.5, PM10. The continuous data were analyzed for the variance of IAQ and influence of environmental factors. According to this study, PM2.5/PM10 and PM10/TSP was 47%, 73% respectively. PM10, PM2.5, CO2 at basement was the highest among each floor. The temperature, relative humidity, PM10, PM2.5, CO2 at the office was the highest for all locations. Air condition and ventilation could significantly decrease the indoor temperature and concentration of CO, TSP, PM10. PM2.5. But only air condition contributed on the reduction of PM2.5. YE CI-HUEI 葉啟輝 2016 學位論文 ; thesis 78 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 大葉大學 === 環境工程學系碩士班 === 105 === Poor indoor air quality has been shown to have adverse effects on human health. This study investigated the indoor air quality of library. The multi-channel air quality monitor was used to monitor VOC, CO, CO2, O3, HCHO, temperature and humidity. While Turnkey Osiris, a digital suspended particulate monitor, measured TSP, PM1, PM2.5, PM10. The continuous data were analyzed for the variance of IAQ and influence of environmental factors. According to this study, PM2.5/PM10 and PM10/TSP was 47%, 73% respectively. PM10, PM2.5, CO2 at basement was the highest among each floor. The temperature, relative humidity, PM10, PM2.5, CO2 at the office was the highest for all locations. Air condition and ventilation could significantly decrease the indoor temperature and concentration of CO, TSP, PM10. PM2.5. But only air condition contributed on the reduction of PM2.5.
author2 YE CI-HUEI
author_facet YE CI-HUEI
YANG YAO-CHUN
楊曜駿
author YANG YAO-CHUN
楊曜駿
spellingShingle YANG YAO-CHUN
楊曜駿
Analysis of Indoor Air Quality at the Library in Dayeh University
author_sort YANG YAO-CHUN
title Analysis of Indoor Air Quality at the Library in Dayeh University
title_short Analysis of Indoor Air Quality at the Library in Dayeh University
title_full Analysis of Indoor Air Quality at the Library in Dayeh University
title_fullStr Analysis of Indoor Air Quality at the Library in Dayeh University
title_full_unstemmed Analysis of Indoor Air Quality at the Library in Dayeh University
title_sort analysis of indoor air quality at the library in dayeh university
publishDate 2016
url http://ndltd.ncl.edu.tw/handle/07155794771351412331
work_keys_str_mv AT yangyaochun analysisofindoorairqualityatthelibraryindayehuniversity
AT yángyàojùn analysisofindoorairqualityatthelibraryindayehuniversity
AT yangyaochun dàyèdàxuétúshūguǎnshìnèikōngqìpǐnzhìfēnxī
AT yángyàojùn dàyèdàxuétúshūguǎnshìnèikōngqìpǐnzhìfēnxī
_version_ 1718435781447516160