Evaluation the Image Quality of Chest CT Examination by Using Objective Analysis with Hybrid Iterative Reconstruction

碩士 === 中臺科技大學 === 醫學影像暨放射科學系暨研究所 === 105 === Hybrid iterative reconstruction (iDose4) is introduced as a computed tomography (CT) image reconstruction technique by Philips Healthcare. The aim of this study was to evaluate the image quality by using Chest Phantom with iDose4. A phantom (multipurp...

Full description

Bibliographic Details
Main Authors: CHEN, PIN-HE, 陳品赫
Other Authors: CHENG, KAI-YUAN
Format: Others
Language:zh-TW
Published: 2017
Online Access:http://ndltd.ncl.edu.tw/handle/r42v9b
id ndltd-TW-105CTC00770035
record_format oai_dc
spelling ndltd-TW-105CTC007700352019-05-15T23:25:04Z http://ndltd.ncl.edu.tw/handle/r42v9b Evaluation the Image Quality of Chest CT Examination by Using Objective Analysis with Hybrid Iterative Reconstruction 運用客觀分析搭配混合型疊代重組法評估電腦斷層胸部檢查之影像品質 CHEN, PIN-HE 陳品赫 碩士 中臺科技大學 醫學影像暨放射科學系暨研究所 105 Hybrid iterative reconstruction (iDose4) is introduced as a computed tomography (CT) image reconstruction technique by Philips Healthcare. The aim of this study was to evaluate the image quality by using Chest Phantom with iDose4. A phantom (multipurpose Chest Phantom N1 “LUNGMAN”) was performed by using parameters of adult chest CT, the protocol of 120 kVp and 180 mAs. For dose reduction, the kVp remained the same, and the mAs was reduced by 40 mAs each time, up to 20 mAs. All image data was reconstructed by FBP and iDose4 level 1-6 to calculate the signal to noise ratio (SNR) , peak signal to noise ratio (PSNR) and root means square error (RMSE) for image quality evaluation. The CTDIvol was showed 14.4, 11.8, 9.2, 6.5, 3.9 and 1.3 mGy for each scanning protocol. Noise reduction compared with FBP and each iDose4 level 1-6 were 12 %, 18 %, 25 %, 32 %, 38 % and 47 %, respectively. The data slowed that the chest CT image quality can be improved at standard protocol and controlled mAs by using iDose4, and the maximum dose reduction was up to 67 %. RMSE and PSNR showed that Level 5 and Level 6 have less image noise, better image quality and smaller different between original and reconstruction image. CHENG, KAI-YUAN 鄭凱元 2017 學位論文 ; thesis 80 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 中臺科技大學 === 醫學影像暨放射科學系暨研究所 === 105 === Hybrid iterative reconstruction (iDose4) is introduced as a computed tomography (CT) image reconstruction technique by Philips Healthcare. The aim of this study was to evaluate the image quality by using Chest Phantom with iDose4. A phantom (multipurpose Chest Phantom N1 “LUNGMAN”) was performed by using parameters of adult chest CT, the protocol of 120 kVp and 180 mAs. For dose reduction, the kVp remained the same, and the mAs was reduced by 40 mAs each time, up to 20 mAs. All image data was reconstructed by FBP and iDose4 level 1-6 to calculate the signal to noise ratio (SNR) , peak signal to noise ratio (PSNR) and root means square error (RMSE) for image quality evaluation. The CTDIvol was showed 14.4, 11.8, 9.2, 6.5, 3.9 and 1.3 mGy for each scanning protocol. Noise reduction compared with FBP and each iDose4 level 1-6 were 12 %, 18 %, 25 %, 32 %, 38 % and 47 %, respectively. The data slowed that the chest CT image quality can be improved at standard protocol and controlled mAs by using iDose4, and the maximum dose reduction was up to 67 %. RMSE and PSNR showed that Level 5 and Level 6 have less image noise, better image quality and smaller different between original and reconstruction image.
author2 CHENG, KAI-YUAN
author_facet CHENG, KAI-YUAN
CHEN, PIN-HE
陳品赫
author CHEN, PIN-HE
陳品赫
spellingShingle CHEN, PIN-HE
陳品赫
Evaluation the Image Quality of Chest CT Examination by Using Objective Analysis with Hybrid Iterative Reconstruction
author_sort CHEN, PIN-HE
title Evaluation the Image Quality of Chest CT Examination by Using Objective Analysis with Hybrid Iterative Reconstruction
title_short Evaluation the Image Quality of Chest CT Examination by Using Objective Analysis with Hybrid Iterative Reconstruction
title_full Evaluation the Image Quality of Chest CT Examination by Using Objective Analysis with Hybrid Iterative Reconstruction
title_fullStr Evaluation the Image Quality of Chest CT Examination by Using Objective Analysis with Hybrid Iterative Reconstruction
title_full_unstemmed Evaluation the Image Quality of Chest CT Examination by Using Objective Analysis with Hybrid Iterative Reconstruction
title_sort evaluation the image quality of chest ct examination by using objective analysis with hybrid iterative reconstruction
publishDate 2017
url http://ndltd.ncl.edu.tw/handle/r42v9b
work_keys_str_mv AT chenpinhe evaluationtheimagequalityofchestctexaminationbyusingobjectiveanalysiswithhybriditerativereconstruction
AT chénpǐnhè evaluationtheimagequalityofchestctexaminationbyusingobjectiveanalysiswithhybriditerativereconstruction
AT chenpinhe yùnyòngkèguānfēnxīdāpèihùnhéxíngdiédàizhòngzǔfǎpínggūdiànnǎoduàncéngxiōngbùjiǎncházhīyǐngxiàngpǐnzhì
AT chénpǐnhè yùnyòngkèguānfēnxīdāpèihùnhéxíngdiédàizhòngzǔfǎpínggūdiànnǎoduàncéngxiōngbùjiǎncházhīyǐngxiàngpǐnzhì
_version_ 1719147818479779840