A Study on the Analysis of XLPE Power Cable Insulation with Very Low Frequency Tan Delta and Monitored Withstand Test

碩士 === 國立雲林科技大學 === 電機工程系 === 104 === High voltage XLPE power cable is often used for power transmission and distribu-tion system in Taiwan. DC voltage insulation testing is commonly applied as withstand test or leakage current measurement technique to analyze the insulation of power cables. DC volt...

Full description

Bibliographic Details
Main Authors: CHIEN, I LUN, 簡翊倫
Other Authors: Wang, Yaw-Juen
Format: Others
Language:zh-TW
Published: 2016
Online Access:http://ndltd.ncl.edu.tw/handle/64928632356621360696
id ndltd-TW-104YUNT0441086
record_format oai_dc
spelling ndltd-TW-104YUNT04410862017-10-15T04:37:22Z http://ndltd.ncl.edu.tw/handle/64928632356621360696 A Study on the Analysis of XLPE Power Cable Insulation with Very Low Frequency Tan Delta and Monitored Withstand Test 以極低頻絕緣診斷與耐壓測試分析交連聚乙烯電力電纜絕緣之研究 CHIEN, I LUN 簡翊倫 碩士 國立雲林科技大學 電機工程系 104 High voltage XLPE power cable is often used for power transmission and distribu-tion system in Taiwan. DC voltage insulation testing is commonly applied as withstand test or leakage current measurement technique to analyze the insulation of power cables. DC voltage insulation testing devices are portable and cost-effective, but it is a destruc-tive test. It is recommended to assess the insulation of high voltage XLPE power cable by simple withstand and tangent delta test with very low frequency (VLF: 0.01~0.1 Hz) sine wave voltage sources to overcome the weak point of the DC voltage insulation test-ing, and assess the insulation precisely. So far, the assessment criteria reported in the journal literature and IEEE standard are established by the cable system database in the North American region. In this research, we introduced a convenient cable insulation diagnostic system with VLF instrument in our field testing. Until now we have accumu-lated a lot of experience in the diagnostic system, and we established a new suitable as-sessment criterion by a cable system database in Taiwan. Thus, we can deduce possible causes of a defect in cable insulation from the condition assessment. In this way, the cost of resetting defective power cable systems can be reduced and the safety and quali-ty of electrical equipment can be improved. Wang, Yaw-Juen 王耀諄 2016 學位論文 ; thesis 73 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立雲林科技大學 === 電機工程系 === 104 === High voltage XLPE power cable is often used for power transmission and distribu-tion system in Taiwan. DC voltage insulation testing is commonly applied as withstand test or leakage current measurement technique to analyze the insulation of power cables. DC voltage insulation testing devices are portable and cost-effective, but it is a destruc-tive test. It is recommended to assess the insulation of high voltage XLPE power cable by simple withstand and tangent delta test with very low frequency (VLF: 0.01~0.1 Hz) sine wave voltage sources to overcome the weak point of the DC voltage insulation test-ing, and assess the insulation precisely. So far, the assessment criteria reported in the journal literature and IEEE standard are established by the cable system database in the North American region. In this research, we introduced a convenient cable insulation diagnostic system with VLF instrument in our field testing. Until now we have accumu-lated a lot of experience in the diagnostic system, and we established a new suitable as-sessment criterion by a cable system database in Taiwan. Thus, we can deduce possible causes of a defect in cable insulation from the condition assessment. In this way, the cost of resetting defective power cable systems can be reduced and the safety and quali-ty of electrical equipment can be improved.
author2 Wang, Yaw-Juen
author_facet Wang, Yaw-Juen
CHIEN, I LUN
簡翊倫
author CHIEN, I LUN
簡翊倫
spellingShingle CHIEN, I LUN
簡翊倫
A Study on the Analysis of XLPE Power Cable Insulation with Very Low Frequency Tan Delta and Monitored Withstand Test
author_sort CHIEN, I LUN
title A Study on the Analysis of XLPE Power Cable Insulation with Very Low Frequency Tan Delta and Monitored Withstand Test
title_short A Study on the Analysis of XLPE Power Cable Insulation with Very Low Frequency Tan Delta and Monitored Withstand Test
title_full A Study on the Analysis of XLPE Power Cable Insulation with Very Low Frequency Tan Delta and Monitored Withstand Test
title_fullStr A Study on the Analysis of XLPE Power Cable Insulation with Very Low Frequency Tan Delta and Monitored Withstand Test
title_full_unstemmed A Study on the Analysis of XLPE Power Cable Insulation with Very Low Frequency Tan Delta and Monitored Withstand Test
title_sort study on the analysis of xlpe power cable insulation with very low frequency tan delta and monitored withstand test
publishDate 2016
url http://ndltd.ncl.edu.tw/handle/64928632356621360696
work_keys_str_mv AT chienilun astudyontheanalysisofxlpepowercableinsulationwithverylowfrequencytandeltaandmonitoredwithstandtest
AT jiǎnyìlún astudyontheanalysisofxlpepowercableinsulationwithverylowfrequencytandeltaandmonitoredwithstandtest
AT chienilun yǐjídīpínjuéyuánzhěnduànyǔnàiyācèshìfēnxījiāoliánjùyǐxīdiànlìdiànlǎnjuéyuánzhīyánjiū
AT jiǎnyìlún yǐjídīpínjuéyuánzhěnduànyǔnàiyācèshìfēnxījiāoliánjùyǐxīdiànlìdiànlǎnjuéyuánzhīyánjiū
AT chienilun studyontheanalysisofxlpepowercableinsulationwithverylowfrequencytandeltaandmonitoredwithstandtest
AT jiǎnyìlún studyontheanalysisofxlpepowercableinsulationwithverylowfrequencytandeltaandmonitoredwithstandtest
_version_ 1718555429872599040