Effect of Smoke Diffusion Due To Blower Operation of Air-conditioning System in theHospital Fire - A Case Study of A Hospital Room

碩士 === 吳鳳科技大學 === 消防研究所 === 104 === In practice, Fan-Coil units always are installed as air-conditioning equipments in many offices or hospital rooms to reach the set conditions of the air conditioning in Taiwan.In recent years, Standards forEstablishment of Health CareFacilities" and Standards...

Full description

Bibliographic Details
Main Authors: Kuo-Tai Hsu, 許國泰
Other Authors: Yung-Lung Chen
Format: Others
Language:zh-TW
Published: 2016
Online Access:http://ndltd.ncl.edu.tw/handle/u32z3r
id ndltd-TW-104WFIT0269003
record_format oai_dc
spelling ndltd-TW-104WFIT02690032019-05-15T22:34:18Z http://ndltd.ncl.edu.tw/handle/u32z3r Effect of Smoke Diffusion Due To Blower Operation of Air-conditioning System in theHospital Fire - A Case Study of A Hospital Room 醫療院所空調設備送風機對火災濃煙影響之研究—以病房空間為例 Kuo-Tai Hsu 許國泰 碩士 吳鳳科技大學 消防研究所 104 In practice, Fan-Coil units always are installed as air-conditioning equipments in many offices or hospital rooms to reach the set conditions of the air conditioning in Taiwan.In recent years, Standards forEstablishment of Health CareFacilities" and Standards forEstablishment of Hospitalsformulatedby the Ministry of Health and Welfarehave amended the Article No. 3: It’s necessary for building air-conditioning equipment to install the power switch interlocking device with fire detectors to automatically cut off the function when fire detected. There are no clear specification in the regulation of Building Technical Regulationsformulatedby the Construction Department and Standard for Installation of Fire Safety Equipments Based on Use and Occupancy formulatedby the Fire Department to control the air conditioning system when fire occured, neitherto requirehow the interlocking of fire detection equipment.FDS simulation software was used in this study to analyze the effectiveness of thermal zone, as well as to observe the impact relative to smoke on the wall height in LR room.The relation of smoke diffusion and air-conditioning system did not shut down the blower has also been investigated. The air-conditioning did not shut down the blower and smoke diffusion of the association has also been explored.The results showed that the higher height of the partition wall of LR room is better.If the barrier set to the top of the ceiling, a significant block effect to smoke and heat were generated in the fire scene.From the simulation results, it may not cause harm to another compartmentwhen the blower is not closed. Positive manner to the heat generated by the combustion of fire room, by the door extrusion discharge. Heat generated by the combustion in fire room can be discharged to outside through positive pressure mode. Yung-Lung Chen Chung-Hwei Su 陳永隆 蘇崇輝 2016 學位論文 ; thesis 63 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 吳鳳科技大學 === 消防研究所 === 104 === In practice, Fan-Coil units always are installed as air-conditioning equipments in many offices or hospital rooms to reach the set conditions of the air conditioning in Taiwan.In recent years, Standards forEstablishment of Health CareFacilities" and Standards forEstablishment of Hospitalsformulatedby the Ministry of Health and Welfarehave amended the Article No. 3: It’s necessary for building air-conditioning equipment to install the power switch interlocking device with fire detectors to automatically cut off the function when fire detected. There are no clear specification in the regulation of Building Technical Regulationsformulatedby the Construction Department and Standard for Installation of Fire Safety Equipments Based on Use and Occupancy formulatedby the Fire Department to control the air conditioning system when fire occured, neitherto requirehow the interlocking of fire detection equipment.FDS simulation software was used in this study to analyze the effectiveness of thermal zone, as well as to observe the impact relative to smoke on the wall height in LR room.The relation of smoke diffusion and air-conditioning system did not shut down the blower has also been investigated. The air-conditioning did not shut down the blower and smoke diffusion of the association has also been explored.The results showed that the higher height of the partition wall of LR room is better.If the barrier set to the top of the ceiling, a significant block effect to smoke and heat were generated in the fire scene.From the simulation results, it may not cause harm to another compartmentwhen the blower is not closed. Positive manner to the heat generated by the combustion of fire room, by the door extrusion discharge. Heat generated by the combustion in fire room can be discharged to outside through positive pressure mode.
author2 Yung-Lung Chen
author_facet Yung-Lung Chen
Kuo-Tai Hsu
許國泰
author Kuo-Tai Hsu
許國泰
spellingShingle Kuo-Tai Hsu
許國泰
Effect of Smoke Diffusion Due To Blower Operation of Air-conditioning System in theHospital Fire - A Case Study of A Hospital Room
author_sort Kuo-Tai Hsu
title Effect of Smoke Diffusion Due To Blower Operation of Air-conditioning System in theHospital Fire - A Case Study of A Hospital Room
title_short Effect of Smoke Diffusion Due To Blower Operation of Air-conditioning System in theHospital Fire - A Case Study of A Hospital Room
title_full Effect of Smoke Diffusion Due To Blower Operation of Air-conditioning System in theHospital Fire - A Case Study of A Hospital Room
title_fullStr Effect of Smoke Diffusion Due To Blower Operation of Air-conditioning System in theHospital Fire - A Case Study of A Hospital Room
title_full_unstemmed Effect of Smoke Diffusion Due To Blower Operation of Air-conditioning System in theHospital Fire - A Case Study of A Hospital Room
title_sort effect of smoke diffusion due to blower operation of air-conditioning system in thehospital fire - a case study of a hospital room
publishDate 2016
url http://ndltd.ncl.edu.tw/handle/u32z3r
work_keys_str_mv AT kuotaihsu effectofsmokediffusionduetobloweroperationofairconditioningsysteminthehospitalfireacasestudyofahospitalroom
AT xǔguótài effectofsmokediffusionduetobloweroperationofairconditioningsysteminthehospitalfireacasestudyofahospitalroom
AT kuotaihsu yīliáoyuànsuǒkōngdiàoshèbèisòngfēngjīduìhuǒzāinóngyānyǐngxiǎngzhīyánjiūyǐbìngfángkōngjiānwèilì
AT xǔguótài yīliáoyuànsuǒkōngdiàoshèbèisòngfēngjīduìhuǒzāinóngyānyǐngxiǎngzhīyánjiūyǐbìngfángkōngjiānwèilì
_version_ 1719132210771001344