New Type Fin-Ellipse Tube Coil Heat Exchanger In Cleanroom

碩士 === 國立臺北科技大學 === 能源與冷凍空調工程系碩士班 === 104 === In theoretical analysis and experimental methods Discussion and performance of the oval tube heat exchanger tube coil heat exchanger, analyzed under different humidity environments, standards, as well as heating of the elliptic tube heat exchanger coil r...

Full description

Bibliographic Details
Main Authors: Chuan Hui Tsai, 蔡川輝
Other Authors: 胡石政
Format: Others
Language:zh-TW
Online Access:http://ndltd.ncl.edu.tw/handle/udtjj8
id ndltd-TW-104TIT05703041
record_format oai_dc
spelling ndltd-TW-104TIT057030412019-05-15T22:54:23Z http://ndltd.ncl.edu.tw/handle/udtjj8 New Type Fin-Ellipse Tube Coil Heat Exchanger In Cleanroom 潔淨室用新型橢圓管式盤管熱交換器 Chuan Hui Tsai 蔡川輝 碩士 國立臺北科技大學 能源與冷凍空調工程系碩士班 104 In theoretical analysis and experimental methods Discussion and performance of the oval tube heat exchanger tube coil heat exchanger, analyzed under different humidity environments, standards, as well as heating of the elliptic tube heat exchanger coil round influence and Comparative tube heat exchangers. Experimental results that under the oval-tube heat exchanger on the air side. Velocity from 1 ~ 5m / s, when the air passes through the coil, the pressure drop, the amount of heat exchange with the forward speed increases, and the heat transfer coefficient, Reynolds New race and the number will rise with increasing forward speed, wherein the heat transfer coefficient elliptical fin tube heat exchanger will be higher 6% to 13% larger than traditional fin tube heat exchangers, oval fin tubes pressure drop type heat exchanger will be 26% to 45% lower than conventional fin tube heat exchangers, better than ordinary tube heat exchanger, thus improving the performance of the heat exchanger.Data measured by the performance test results of experiments on the heat exchanger and are subject allowed calculation error correction, then the data analysis concluded that more accurate when the MAU cleanroom operation each year in energy consumption per year save 28150.9 MWH 胡石政 學位論文 ; thesis 0 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立臺北科技大學 === 能源與冷凍空調工程系碩士班 === 104 === In theoretical analysis and experimental methods Discussion and performance of the oval tube heat exchanger tube coil heat exchanger, analyzed under different humidity environments, standards, as well as heating of the elliptic tube heat exchanger coil round influence and Comparative tube heat exchangers. Experimental results that under the oval-tube heat exchanger on the air side. Velocity from 1 ~ 5m / s, when the air passes through the coil, the pressure drop, the amount of heat exchange with the forward speed increases, and the heat transfer coefficient, Reynolds New race and the number will rise with increasing forward speed, wherein the heat transfer coefficient elliptical fin tube heat exchanger will be higher 6% to 13% larger than traditional fin tube heat exchangers, oval fin tubes pressure drop type heat exchanger will be 26% to 45% lower than conventional fin tube heat exchangers, better than ordinary tube heat exchanger, thus improving the performance of the heat exchanger.Data measured by the performance test results of experiments on the heat exchanger and are subject allowed calculation error correction, then the data analysis concluded that more accurate when the MAU cleanroom operation each year in energy consumption per year save 28150.9 MWH
author2 胡石政
author_facet 胡石政
Chuan Hui Tsai
蔡川輝
author Chuan Hui Tsai
蔡川輝
spellingShingle Chuan Hui Tsai
蔡川輝
New Type Fin-Ellipse Tube Coil Heat Exchanger In Cleanroom
author_sort Chuan Hui Tsai
title New Type Fin-Ellipse Tube Coil Heat Exchanger In Cleanroom
title_short New Type Fin-Ellipse Tube Coil Heat Exchanger In Cleanroom
title_full New Type Fin-Ellipse Tube Coil Heat Exchanger In Cleanroom
title_fullStr New Type Fin-Ellipse Tube Coil Heat Exchanger In Cleanroom
title_full_unstemmed New Type Fin-Ellipse Tube Coil Heat Exchanger In Cleanroom
title_sort new type fin-ellipse tube coil heat exchanger in cleanroom
url http://ndltd.ncl.edu.tw/handle/udtjj8
work_keys_str_mv AT chuanhuitsai newtypefinellipsetubecoilheatexchangerincleanroom
AT càichuānhuī newtypefinellipsetubecoilheatexchangerincleanroom
AT chuanhuitsai jiéjìngshìyòngxīnxíngtuǒyuánguǎnshìpánguǎnrèjiāohuànqì
AT càichuānhuī jiéjìngshìyòngxīnxíngtuǒyuánguǎnshìpánguǎnrèjiāohuànqì
_version_ 1719137955645227008