Performance Improvement of Circulating Inclined Fluidized Bed Applied to Desiccant Dehumidification Systems

碩士 === 國立臺灣大學 === 機械工程學研究所 === 104 === The purpose of this study is to design a inclined circulating fluidized bed that maintains a healthy indoor environment and be energy-efficient. With gravity, the design of particle channels vertical to the bed and the characteristics of the fluidized bed. The...

Full description

Bibliographic Details
Main Authors: Tai-Chih Hung, 洪泰智
Other Authors: 陳希立
Format: Others
Language:zh-TW
Published: 2016
Online Access:http://ndltd.ncl.edu.tw/handle/02491290140676452898
id ndltd-TW-104NTU05489068
record_format oai_dc
spelling ndltd-TW-104NTU054890682017-04-24T04:23:46Z http://ndltd.ncl.edu.tw/handle/02491290140676452898 Performance Improvement of Circulating Inclined Fluidized Bed Applied to Desiccant Dehumidification Systems 改良式傾斜循環流體化床應用於吸附除濕系統 Tai-Chih Hung 洪泰智 碩士 國立臺灣大學 機械工程學研究所 104 The purpose of this study is to design a inclined circulating fluidized bed that maintains a healthy indoor environment and be energy-efficient. With gravity, the design of particle channels vertical to the bed and the characteristics of the fluidized bed. The system can adsorb water continuously without funnel and corner joints. First, compared to the circulating inclined fluidized beds device. The total adsorption amounts of circulating improved inclined fluidized bed increased by 6.8% when the air speed was 3 m/s, the entrance air temperature was 27℃and relative humidity was 70% in the adsorption bed, the entrance air temperature was 50℃in the desorption bed , and filled with 4mm diameter silica gel, total weight 550 g, in each bed. Under this condition, the pressure loss and the energy consumption of fan reduced by 10.6% and 11.8% respectively. The result indicated that the circulating improved inclined fluidized bed has better dehumidification performance than the circulating inclined fluidized bed. Second, changed the geometric parameters of the circulating improved inclined fluidized bed. Maintain the high of desorption bed base and adjust particle channels to 20 cm high of the adsorption bed, accordingly, the total adsorption amounts increased by 16%. Further, simulation ambient air conditions at Taipei 2014 annual. The total adsorption amounts was 729.5 kg , compared to the circulating inclined fluidized beds device, the dehumidification performance of circulating improved inclined fluidized bed increased by 14.1% When the entrance air temperature was 30℃and relative humidity was 80% in the adsorption bed, the entrance air temperature was50℃ in the desorption bed, compared to the circulating improved inclined fluidized beds device with silica gel, the adsorption capacity of particles mixed with silica gel and polymer was lower than silica gel 11.6%. The result indicated that silica gel has better particles mixed with silica gel and polymer. Last, the dehumidification will increase 5.7% when inclined circulating fluidized bed adjust to 10°, but this system can not maintaining stability in a long time. 陳希立 2016 學位論文 ; thesis 72 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立臺灣大學 === 機械工程學研究所 === 104 === The purpose of this study is to design a inclined circulating fluidized bed that maintains a healthy indoor environment and be energy-efficient. With gravity, the design of particle channels vertical to the bed and the characteristics of the fluidized bed. The system can adsorb water continuously without funnel and corner joints. First, compared to the circulating inclined fluidized beds device. The total adsorption amounts of circulating improved inclined fluidized bed increased by 6.8% when the air speed was 3 m/s, the entrance air temperature was 27℃and relative humidity was 70% in the adsorption bed, the entrance air temperature was 50℃in the desorption bed , and filled with 4mm diameter silica gel, total weight 550 g, in each bed. Under this condition, the pressure loss and the energy consumption of fan reduced by 10.6% and 11.8% respectively. The result indicated that the circulating improved inclined fluidized bed has better dehumidification performance than the circulating inclined fluidized bed. Second, changed the geometric parameters of the circulating improved inclined fluidized bed. Maintain the high of desorption bed base and adjust particle channels to 20 cm high of the adsorption bed, accordingly, the total adsorption amounts increased by 16%. Further, simulation ambient air conditions at Taipei 2014 annual. The total adsorption amounts was 729.5 kg , compared to the circulating inclined fluidized beds device, the dehumidification performance of circulating improved inclined fluidized bed increased by 14.1% When the entrance air temperature was 30℃and relative humidity was 80% in the adsorption bed, the entrance air temperature was50℃ in the desorption bed, compared to the circulating improved inclined fluidized beds device with silica gel, the adsorption capacity of particles mixed with silica gel and polymer was lower than silica gel 11.6%. The result indicated that silica gel has better particles mixed with silica gel and polymer. Last, the dehumidification will increase 5.7% when inclined circulating fluidized bed adjust to 10°, but this system can not maintaining stability in a long time.
author2 陳希立
author_facet 陳希立
Tai-Chih Hung
洪泰智
author Tai-Chih Hung
洪泰智
spellingShingle Tai-Chih Hung
洪泰智
Performance Improvement of Circulating Inclined Fluidized Bed Applied to Desiccant Dehumidification Systems
author_sort Tai-Chih Hung
title Performance Improvement of Circulating Inclined Fluidized Bed Applied to Desiccant Dehumidification Systems
title_short Performance Improvement of Circulating Inclined Fluidized Bed Applied to Desiccant Dehumidification Systems
title_full Performance Improvement of Circulating Inclined Fluidized Bed Applied to Desiccant Dehumidification Systems
title_fullStr Performance Improvement of Circulating Inclined Fluidized Bed Applied to Desiccant Dehumidification Systems
title_full_unstemmed Performance Improvement of Circulating Inclined Fluidized Bed Applied to Desiccant Dehumidification Systems
title_sort performance improvement of circulating inclined fluidized bed applied to desiccant dehumidification systems
publishDate 2016
url http://ndltd.ncl.edu.tw/handle/02491290140676452898
work_keys_str_mv AT taichihhung performanceimprovementofcirculatinginclinedfluidizedbedappliedtodesiccantdehumidificationsystems
AT hóngtàizhì performanceimprovementofcirculatinginclinedfluidizedbedappliedtodesiccantdehumidificationsystems
AT taichihhung gǎiliángshìqīngxiéxúnhuánliútǐhuàchuángyīngyòngyúxīfùchúshīxìtǒng
AT hóngtàizhì gǎiliángshìqīngxiéxúnhuánliútǐhuàchuángyīngyòngyúxīfùchúshīxìtǒng
_version_ 1718444225871216640