Research on Engergy Saving for Automatic Control of Cooling Tower

碩士 === 國立高雄海洋科技大學 === 輪機工程研究所 === 104 === With the changing of time, the progress of technology will improve our  environment and reduce the use of manpower. Under the global purpose of energy saving and carbon reduction, the automation of engineering will play an important role for improving the co...

Full description

Bibliographic Details
Main Authors: WU,LI-CHUN, 伍立群
Other Authors: Chang-Hua Lien
Format: Others
Language:zh-TW
Published: 2016
Online Access:http://ndltd.ncl.edu.tw/handle/33419921952187473865
id ndltd-TW-104NKIM0484017
record_format oai_dc
spelling ndltd-TW-104NKIM04840172017-09-17T04:24:17Z http://ndltd.ncl.edu.tw/handle/33419921952187473865 Research on Engergy Saving for Automatic Control of Cooling Tower 冷卻水塔自動控制在節能應用上之研究 WU,LI-CHUN 伍立群 碩士 國立高雄海洋科技大學 輪機工程研究所 104 With the changing of time, the progress of technology will improve our  environment and reduce the use of manpower. Under the global purpose of energy saving and carbon reduction, the automation of engineering will play an important role for improving the convenience for life of human. This research is based on cooling towers are all running 24 hours for every day of a year despite the factory for chiller load changing. Is it reasonable for this running on any operation conditions? In fact, the appropriate amount of chiller plant cooling tower should be calculated according to the load change. In order to achieve the concept of energy saving policy, the start or stop for cooling tower can be handled by a simple Arduino controller in this thesis. This system is established according to the change on maximum and minimum loads for cooling towers operation in summer and winter, respectively. In this research, the suitable number and switching order for cooling towers operation will be proposed according to the demand of load change. The energy saving and carbon reduction can be done. The running service life of equipment can be extended subjected to switching on the cooling tower. Chang-Hua Lien 連長華 2016 學位論文 ; thesis 77 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立高雄海洋科技大學 === 輪機工程研究所 === 104 === With the changing of time, the progress of technology will improve our  environment and reduce the use of manpower. Under the global purpose of energy saving and carbon reduction, the automation of engineering will play an important role for improving the convenience for life of human. This research is based on cooling towers are all running 24 hours for every day of a year despite the factory for chiller load changing. Is it reasonable for this running on any operation conditions? In fact, the appropriate amount of chiller plant cooling tower should be calculated according to the load change. In order to achieve the concept of energy saving policy, the start or stop for cooling tower can be handled by a simple Arduino controller in this thesis. This system is established according to the change on maximum and minimum loads for cooling towers operation in summer and winter, respectively. In this research, the suitable number and switching order for cooling towers operation will be proposed according to the demand of load change. The energy saving and carbon reduction can be done. The running service life of equipment can be extended subjected to switching on the cooling tower.
author2 Chang-Hua Lien
author_facet Chang-Hua Lien
WU,LI-CHUN
伍立群
author WU,LI-CHUN
伍立群
spellingShingle WU,LI-CHUN
伍立群
Research on Engergy Saving for Automatic Control of Cooling Tower
author_sort WU,LI-CHUN
title Research on Engergy Saving for Automatic Control of Cooling Tower
title_short Research on Engergy Saving for Automatic Control of Cooling Tower
title_full Research on Engergy Saving for Automatic Control of Cooling Tower
title_fullStr Research on Engergy Saving for Automatic Control of Cooling Tower
title_full_unstemmed Research on Engergy Saving for Automatic Control of Cooling Tower
title_sort research on engergy saving for automatic control of cooling tower
publishDate 2016
url http://ndltd.ncl.edu.tw/handle/33419921952187473865
work_keys_str_mv AT wulichun researchonengergysavingforautomaticcontrolofcoolingtower
AT wǔlìqún researchonengergysavingforautomaticcontrolofcoolingtower
AT wulichun lěngquèshuǐtǎzìdòngkòngzhìzàijiénéngyīngyòngshàngzhīyánjiū
AT wǔlìqún lěngquèshuǐtǎzìdòngkòngzhìzàijiénéngyīngyòngshàngzhīyánjiū
_version_ 1718537121835253760