Process Improvement of Hexagonal - Type pH and Temperature Sensing Probe and Three Dimensional Heart Muscle pH Monitoring with Temperature Compensation

碩士 === 國立交通大學 === 電子工程學系 電子研究所 === 104 === This thesis improve the process of a hexagonal type micro-machined silicon needle comprising of a Cu-based resistance temperature probe and a (IrOx)/AgCl pH sensing probe which are manufactured by flip-bond technology. We discuss the difference of AgCl film...

Full description

Bibliographic Details
Main Authors: Li, Yuan-Ding, 李元鼎
Other Authors: Yu-Ting Cheng
Format: Others
Language:zh-TW
Published: 2015
Online Access:http://ndltd.ncl.edu.tw/handle/61998950227319816193
id ndltd-TW-104NCTU5428018
record_format oai_dc
spelling ndltd-TW-104NCTU54280182017-09-15T04:40:08Z http://ndltd.ncl.edu.tw/handle/61998950227319816193 Process Improvement of Hexagonal - Type pH and Temperature Sensing Probe and Three Dimensional Heart Muscle pH Monitoring with Temperature Compensation 六角柱體酸鹼/溫度感測探針之製程改進與三維溫度補償之心肌監測應用 Li, Yuan-Ding 李元鼎 碩士 國立交通大學 電子工程學系 電子研究所 104 This thesis improve the process of a hexagonal type micro-machined silicon needle comprising of a Cu-based resistance temperature probe and a (IrOx)/AgCl pH sensing probe which are manufactured by flip-bond technology. We discuss the difference of AgCl film grow on sputtered and electroplated Ag film and the effect of IrOx by followed process , then modify the process flow to improve the yield of sensing probe . By the probe, we can execute real-time myocardium monitoring in a pig-heart and set up a three-dimensional image to observe pH distribution. Besides, according to the Nernst equation, we can construct a temperature compensation map and observe a 0.5 of pH value difference after with temperature compensation. The sensing probe can exhibit 0.029Ω/°C and -60~-70mV/pH sensitivity for the detection of pH and temperature, respectively. We expect the sensing probe can facilitate a multi-point detection with the usage of multiple probes, especially for enhance the success rate of heart transplant surgery. Yu-Ting Cheng 鄭裕庭 2015 學位論文 ; thesis 26 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立交通大學 === 電子工程學系 電子研究所 === 104 === This thesis improve the process of a hexagonal type micro-machined silicon needle comprising of a Cu-based resistance temperature probe and a (IrOx)/AgCl pH sensing probe which are manufactured by flip-bond technology. We discuss the difference of AgCl film grow on sputtered and electroplated Ag film and the effect of IrOx by followed process , then modify the process flow to improve the yield of sensing probe . By the probe, we can execute real-time myocardium monitoring in a pig-heart and set up a three-dimensional image to observe pH distribution. Besides, according to the Nernst equation, we can construct a temperature compensation map and observe a 0.5 of pH value difference after with temperature compensation. The sensing probe can exhibit 0.029Ω/°C and -60~-70mV/pH sensitivity for the detection of pH and temperature, respectively. We expect the sensing probe can facilitate a multi-point detection with the usage of multiple probes, especially for enhance the success rate of heart transplant surgery.
author2 Yu-Ting Cheng
author_facet Yu-Ting Cheng
Li, Yuan-Ding
李元鼎
author Li, Yuan-Ding
李元鼎
spellingShingle Li, Yuan-Ding
李元鼎
Process Improvement of Hexagonal - Type pH and Temperature Sensing Probe and Three Dimensional Heart Muscle pH Monitoring with Temperature Compensation
author_sort Li, Yuan-Ding
title Process Improvement of Hexagonal - Type pH and Temperature Sensing Probe and Three Dimensional Heart Muscle pH Monitoring with Temperature Compensation
title_short Process Improvement of Hexagonal - Type pH and Temperature Sensing Probe and Three Dimensional Heart Muscle pH Monitoring with Temperature Compensation
title_full Process Improvement of Hexagonal - Type pH and Temperature Sensing Probe and Three Dimensional Heart Muscle pH Monitoring with Temperature Compensation
title_fullStr Process Improvement of Hexagonal - Type pH and Temperature Sensing Probe and Three Dimensional Heart Muscle pH Monitoring with Temperature Compensation
title_full_unstemmed Process Improvement of Hexagonal - Type pH and Temperature Sensing Probe and Three Dimensional Heart Muscle pH Monitoring with Temperature Compensation
title_sort process improvement of hexagonal - type ph and temperature sensing probe and three dimensional heart muscle ph monitoring with temperature compensation
publishDate 2015
url http://ndltd.ncl.edu.tw/handle/61998950227319816193
work_keys_str_mv AT liyuanding processimprovementofhexagonaltypephandtemperaturesensingprobeandthreedimensionalheartmusclephmonitoringwithtemperaturecompensation
AT lǐyuándǐng processimprovementofhexagonaltypephandtemperaturesensingprobeandthreedimensionalheartmusclephmonitoringwithtemperaturecompensation
AT liyuanding liùjiǎozhùtǐsuānjiǎnwēndùgǎncètànzhēnzhīzhìchénggǎijìnyǔsānwéiwēndùbǔchángzhīxīnjījiāncèyīngyòng
AT lǐyuándǐng liùjiǎozhùtǐsuānjiǎnwēndùgǎncètànzhēnzhīzhìchénggǎijìnyǔsānwéiwēndùbǔchángzhīxīnjījiāncèyīngyòng
_version_ 1718533735381467136