Improvement of Three-phase Voltage Unbalance Characteristics Due to U-V/V-V Connections of Transformers Using a D-STATCOM
碩士 === 國立成功大學 === 電機工程學系 === 104 === The U-V or V-V winding connection of two single-phase distribution transformers is widely used in most utility companies including Taiwan Power Company (TPC) to deliver power to various three-phase loads. Such special winding connection can cause three-phase volt...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
2016
|
Online Access: | http://ndltd.ncl.edu.tw/handle/27641960399058856500 |
id |
ndltd-TW-104NCKU5442113 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-104NCKU54421132017-10-01T04:30:09Z http://ndltd.ncl.edu.tw/handle/27641960399058856500 Improvement of Three-phase Voltage Unbalance Characteristics Due to U-V/V-V Connections of Transformers Using a D-STATCOM 配電型靜態同步補償器應用於變壓器U-V/V-V連接之電壓不平衡改善 Wei-ShengLiu 劉威盛 碩士 國立成功大學 電機工程學系 104 The U-V or V-V winding connection of two single-phase distribution transformers is widely used in most utility companies including Taiwan Power Company (TPC) to deliver power to various three-phase loads. Such special winding connection can cause three-phase voltage unbalance which leads to the trip of ground relay, extra power loss on distribution lines, and reduced efficiency of induction motors. This thesis proposes a distributed static synchronous compensator (D-STATCOM) to decrease the voltage unbalance due to U-V or V-V winding connection of distribution transformers. System configuration 1 is based on the IEEE 4-node test feeder with U-V or V-V winding connection of transformers while the D-STATCOM is proposed to reduce three-phase voltage unbalance. System configuration 2 is based on a distribution system of TPC while the location of the D-STATCOM and the modification of U-V/V-V winding connection of transformers are carried out. The simulation results show that the use of the proposed D-STATCOM to reduce three-phase voltage unbalance due to U-V or V-V winding connection of distribution transformers is feasible. Li Wang 王醴 2016 學位論文 ; thesis 135 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 國立成功大學 === 電機工程學系 === 104 === The U-V or V-V winding connection of two single-phase distribution transformers is widely used in most utility companies including Taiwan Power Company (TPC) to deliver power to various three-phase loads. Such special winding connection can cause three-phase voltage unbalance which leads to the trip of ground relay, extra power loss on distribution lines, and reduced efficiency of induction motors. This thesis proposes a distributed static synchronous compensator (D-STATCOM) to decrease the voltage unbalance due to U-V or V-V winding connection of distribution transformers. System configuration 1 is based on the IEEE 4-node test feeder with U-V or V-V winding connection of transformers while the D-STATCOM is proposed to reduce three-phase voltage unbalance. System configuration 2 is based on a distribution system of TPC while the location of the D-STATCOM and the modification of U-V/V-V winding connection of transformers are carried out. The simulation results show that the use of the proposed D-STATCOM to reduce three-phase voltage unbalance due to U-V or V-V winding connection of distribution transformers is feasible.
|
author2 |
Li Wang |
author_facet |
Li Wang Wei-ShengLiu 劉威盛 |
author |
Wei-ShengLiu 劉威盛 |
spellingShingle |
Wei-ShengLiu 劉威盛 Improvement of Three-phase Voltage Unbalance Characteristics Due to U-V/V-V Connections of Transformers Using a D-STATCOM |
author_sort |
Wei-ShengLiu |
title |
Improvement of Three-phase Voltage Unbalance Characteristics Due to U-V/V-V Connections of Transformers Using a D-STATCOM |
title_short |
Improvement of Three-phase Voltage Unbalance Characteristics Due to U-V/V-V Connections of Transformers Using a D-STATCOM |
title_full |
Improvement of Three-phase Voltage Unbalance Characteristics Due to U-V/V-V Connections of Transformers Using a D-STATCOM |
title_fullStr |
Improvement of Three-phase Voltage Unbalance Characteristics Due to U-V/V-V Connections of Transformers Using a D-STATCOM |
title_full_unstemmed |
Improvement of Three-phase Voltage Unbalance Characteristics Due to U-V/V-V Connections of Transformers Using a D-STATCOM |
title_sort |
improvement of three-phase voltage unbalance characteristics due to u-v/v-v connections of transformers using a d-statcom |
publishDate |
2016 |
url |
http://ndltd.ncl.edu.tw/handle/27641960399058856500 |
work_keys_str_mv |
AT weishengliu improvementofthreephasevoltageunbalancecharacteristicsduetouvvvconnectionsoftransformersusingadstatcom AT liúwēishèng improvementofthreephasevoltageunbalancecharacteristicsduetouvvvconnectionsoftransformersusingadstatcom AT weishengliu pèidiànxíngjìngtàitóngbùbǔchángqìyīngyòngyúbiànyāqìuvvvliánjiēzhīdiànyābùpínghénggǎishàn AT liúwēishèng pèidiànxíngjìngtàitóngbùbǔchángqìyīngyòngyúbiànyāqìuvvvliánjiēzhīdiànyābùpínghénggǎishàn |
_version_ |
1718541928384954368 |