Improvement of Three-phase Voltage Unbalance Characteristics Due to U-V/V-V Connections of Transformers Using a D-STATCOM

碩士 === 國立成功大學 === 電機工程學系 === 104 === The U-V or V-V winding connection of two single-phase distribution transformers is widely used in most utility companies including Taiwan Power Company (TPC) to deliver power to various three-phase loads. Such special winding connection can cause three-phase volt...

Full description

Bibliographic Details
Main Authors: Wei-ShengLiu, 劉威盛
Other Authors: Li Wang
Format: Others
Language:zh-TW
Published: 2016
Online Access:http://ndltd.ncl.edu.tw/handle/27641960399058856500
id ndltd-TW-104NCKU5442113
record_format oai_dc
spelling ndltd-TW-104NCKU54421132017-10-01T04:30:09Z http://ndltd.ncl.edu.tw/handle/27641960399058856500 Improvement of Three-phase Voltage Unbalance Characteristics Due to U-V/V-V Connections of Transformers Using a D-STATCOM 配電型靜態同步補償器應用於變壓器U-V/V-V連接之電壓不平衡改善 Wei-ShengLiu 劉威盛 碩士 國立成功大學 電機工程學系 104 The U-V or V-V winding connection of two single-phase distribution transformers is widely used in most utility companies including Taiwan Power Company (TPC) to deliver power to various three-phase loads. Such special winding connection can cause three-phase voltage unbalance which leads to the trip of ground relay, extra power loss on distribution lines, and reduced efficiency of induction motors. This thesis proposes a distributed static synchronous compensator (D-STATCOM) to decrease the voltage unbalance due to U-V or V-V winding connection of distribution transformers. System configuration 1 is based on the IEEE 4-node test feeder with U-V or V-V winding connection of transformers while the D-STATCOM is proposed to reduce three-phase voltage unbalance. System configuration 2 is based on a distribution system of TPC while the location of the D-STATCOM and the modification of U-V/V-V winding connection of transformers are carried out. The simulation results show that the use of the proposed D-STATCOM to reduce three-phase voltage unbalance due to U-V or V-V winding connection of distribution transformers is feasible. Li Wang 王醴 2016 學位論文 ; thesis 135 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立成功大學 === 電機工程學系 === 104 === The U-V or V-V winding connection of two single-phase distribution transformers is widely used in most utility companies including Taiwan Power Company (TPC) to deliver power to various three-phase loads. Such special winding connection can cause three-phase voltage unbalance which leads to the trip of ground relay, extra power loss on distribution lines, and reduced efficiency of induction motors. This thesis proposes a distributed static synchronous compensator (D-STATCOM) to decrease the voltage unbalance due to U-V or V-V winding connection of distribution transformers. System configuration 1 is based on the IEEE 4-node test feeder with U-V or V-V winding connection of transformers while the D-STATCOM is proposed to reduce three-phase voltage unbalance. System configuration 2 is based on a distribution system of TPC while the location of the D-STATCOM and the modification of U-V/V-V winding connection of transformers are carried out. The simulation results show that the use of the proposed D-STATCOM to reduce three-phase voltage unbalance due to U-V or V-V winding connection of distribution transformers is feasible.
author2 Li Wang
author_facet Li Wang
Wei-ShengLiu
劉威盛
author Wei-ShengLiu
劉威盛
spellingShingle Wei-ShengLiu
劉威盛
Improvement of Three-phase Voltage Unbalance Characteristics Due to U-V/V-V Connections of Transformers Using a D-STATCOM
author_sort Wei-ShengLiu
title Improvement of Three-phase Voltage Unbalance Characteristics Due to U-V/V-V Connections of Transformers Using a D-STATCOM
title_short Improvement of Three-phase Voltage Unbalance Characteristics Due to U-V/V-V Connections of Transformers Using a D-STATCOM
title_full Improvement of Three-phase Voltage Unbalance Characteristics Due to U-V/V-V Connections of Transformers Using a D-STATCOM
title_fullStr Improvement of Three-phase Voltage Unbalance Characteristics Due to U-V/V-V Connections of Transformers Using a D-STATCOM
title_full_unstemmed Improvement of Three-phase Voltage Unbalance Characteristics Due to U-V/V-V Connections of Transformers Using a D-STATCOM
title_sort improvement of three-phase voltage unbalance characteristics due to u-v/v-v connections of transformers using a d-statcom
publishDate 2016
url http://ndltd.ncl.edu.tw/handle/27641960399058856500
work_keys_str_mv AT weishengliu improvementofthreephasevoltageunbalancecharacteristicsduetouvvvconnectionsoftransformersusingadstatcom
AT liúwēishèng improvementofthreephasevoltageunbalancecharacteristicsduetouvvvconnectionsoftransformersusingadstatcom
AT weishengliu pèidiànxíngjìngtàitóngbùbǔchángqìyīngyòngyúbiànyāqìuvvvliánjiēzhīdiànyābùpínghénggǎishàn
AT liúwēishèng pèidiànxíngjìngtàitóngbùbǔchángqìyīngyòngyúbiànyāqìuvvvliánjiēzhīdiànyābùpínghénggǎishàn
_version_ 1718541928384954368