Development of Saliva Collection for Ketamine Rapid Test Strip
碩士 === 國立成功大學 === 工程科學系 === 104 === This thesis presents two saliva collectors, evacuating saliva collector for general tests, and on-site saliva collector for rapid tests. We used cotton roll, absorbent pad and pledget ball to collect saliva and apply the saliva specimens to rapid test strips to ex...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
2016
|
Online Access: | http://ndltd.ncl.edu.tw/handle/31594026438709071830 |
id |
ndltd-TW-104NCKU5028006 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-104NCKU50280062017-09-24T04:40:26Z http://ndltd.ncl.edu.tw/handle/31594026438709071830 Development of Saliva Collection for Ketamine Rapid Test Strip 唾液採集器開發應用於愷他命快速檢測試劑之研究 Cheng-YoShih 施承佑 碩士 國立成功大學 工程科學系 104 This thesis presents two saliva collectors, evacuating saliva collector for general tests, and on-site saliva collector for rapid tests. We used cotton roll, absorbent pad and pledget ball to collect saliva and apply the saliva specimens to rapid test strips to examine the influence of different materials on the adhesion rate of ketamine(KET), the secretion rates of different salivary glands, and the influence of saliva collectors on the performance of rapid test strips. The results reveal that 1) sublingual gland has the highest secretion rate, 2) cotton roll has the lowest KET adhesion rate and a saliva recover rate of 65.2%, and that 3) the proposed saliva collectors could enhance the colorization of test line in quantitative analysis. Yu-Cheng Lin 林裕城 2016 學位論文 ; thesis 107 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 國立成功大學 === 工程科學系 === 104 === This thesis presents two saliva collectors, evacuating saliva collector for general tests, and on-site saliva collector for rapid tests. We used cotton roll, absorbent pad and pledget ball to collect saliva and apply the saliva specimens to rapid test strips to examine the influence of different materials on the adhesion rate of ketamine(KET), the secretion rates of different salivary glands, and the influence of saliva collectors on the performance of rapid test strips. The results reveal that 1) sublingual gland has the highest secretion rate, 2) cotton roll has the lowest KET adhesion rate and a saliva recover rate of 65.2%, and that 3) the proposed saliva collectors could enhance the colorization of test line in quantitative analysis.
|
author2 |
Yu-Cheng Lin |
author_facet |
Yu-Cheng Lin Cheng-YoShih 施承佑 |
author |
Cheng-YoShih 施承佑 |
spellingShingle |
Cheng-YoShih 施承佑 Development of Saliva Collection for Ketamine Rapid Test Strip |
author_sort |
Cheng-YoShih |
title |
Development of Saliva Collection for Ketamine Rapid Test Strip |
title_short |
Development of Saliva Collection for Ketamine Rapid Test Strip |
title_full |
Development of Saliva Collection for Ketamine Rapid Test Strip |
title_fullStr |
Development of Saliva Collection for Ketamine Rapid Test Strip |
title_full_unstemmed |
Development of Saliva Collection for Ketamine Rapid Test Strip |
title_sort |
development of saliva collection for ketamine rapid test strip |
publishDate |
2016 |
url |
http://ndltd.ncl.edu.tw/handle/31594026438709071830 |
work_keys_str_mv |
AT chengyoshih developmentofsalivacollectionforketaminerapidteststrip AT shīchéngyòu developmentofsalivacollectionforketaminerapidteststrip AT chengyoshih tuòyècǎijíqìkāifāyīngyòngyúkǎitāmìngkuàisùjiǎncèshìjìzhīyánjiū AT shīchéngyòu tuòyècǎijíqìkāifāyīngyòngyúkǎitāmìngkuàisùjiǎncèshìjìzhīyánjiū |
_version_ |
1718540060071034880 |