Development of Saliva Collection for Ketamine Rapid Test Strip

碩士 === 國立成功大學 === 工程科學系 === 104 === This thesis presents two saliva collectors, evacuating saliva collector for general tests, and on-site saliva collector for rapid tests. We used cotton roll, absorbent pad and pledget ball to collect saliva and apply the saliva specimens to rapid test strips to ex...

Full description

Bibliographic Details
Main Authors: Cheng-YoShih, 施承佑
Other Authors: Yu-Cheng Lin
Format: Others
Language:zh-TW
Published: 2016
Online Access:http://ndltd.ncl.edu.tw/handle/31594026438709071830
id ndltd-TW-104NCKU5028006
record_format oai_dc
spelling ndltd-TW-104NCKU50280062017-09-24T04:40:26Z http://ndltd.ncl.edu.tw/handle/31594026438709071830 Development of Saliva Collection for Ketamine Rapid Test Strip 唾液採集器開發應用於愷他命快速檢測試劑之研究 Cheng-YoShih 施承佑 碩士 國立成功大學 工程科學系 104 This thesis presents two saliva collectors, evacuating saliva collector for general tests, and on-site saliva collector for rapid tests. We used cotton roll, absorbent pad and pledget ball to collect saliva and apply the saliva specimens to rapid test strips to examine the influence of different materials on the adhesion rate of ketamine(KET), the secretion rates of different salivary glands, and the influence of saliva collectors on the performance of rapid test strips. The results reveal that 1) sublingual gland has the highest secretion rate, 2) cotton roll has the lowest KET adhesion rate and a saliva recover rate of 65.2%, and that 3) the proposed saliva collectors could enhance the colorization of test line in quantitative analysis. Yu-Cheng Lin 林裕城 2016 學位論文 ; thesis 107 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立成功大學 === 工程科學系 === 104 === This thesis presents two saliva collectors, evacuating saliva collector for general tests, and on-site saliva collector for rapid tests. We used cotton roll, absorbent pad and pledget ball to collect saliva and apply the saliva specimens to rapid test strips to examine the influence of different materials on the adhesion rate of ketamine(KET), the secretion rates of different salivary glands, and the influence of saliva collectors on the performance of rapid test strips. The results reveal that 1) sublingual gland has the highest secretion rate, 2) cotton roll has the lowest KET adhesion rate and a saliva recover rate of 65.2%, and that 3) the proposed saliva collectors could enhance the colorization of test line in quantitative analysis.
author2 Yu-Cheng Lin
author_facet Yu-Cheng Lin
Cheng-YoShih
施承佑
author Cheng-YoShih
施承佑
spellingShingle Cheng-YoShih
施承佑
Development of Saliva Collection for Ketamine Rapid Test Strip
author_sort Cheng-YoShih
title Development of Saliva Collection for Ketamine Rapid Test Strip
title_short Development of Saliva Collection for Ketamine Rapid Test Strip
title_full Development of Saliva Collection for Ketamine Rapid Test Strip
title_fullStr Development of Saliva Collection for Ketamine Rapid Test Strip
title_full_unstemmed Development of Saliva Collection for Ketamine Rapid Test Strip
title_sort development of saliva collection for ketamine rapid test strip
publishDate 2016
url http://ndltd.ncl.edu.tw/handle/31594026438709071830
work_keys_str_mv AT chengyoshih developmentofsalivacollectionforketaminerapidteststrip
AT shīchéngyòu developmentofsalivacollectionforketaminerapidteststrip
AT chengyoshih tuòyècǎijíqìkāifāyīngyòngyúkǎitāmìngkuàisùjiǎncèshìjìzhīyánjiū
AT shīchéngyòu tuòyècǎijíqìkāifāyīngyòngyúkǎitāmìngkuàisùjiǎncèshìjìzhīyánjiū
_version_ 1718540060071034880