面板廠房空調冰水系統使用一次側變流量之節能分析

碩士 === 國立勤益科技大學 === 冷凍空調系 === 104 === This study investigates the energy-saving strategy of chiller water system for cleanrooms in a TFT-LCD fab. A Primary-Secondary(P-S) Chiller Water System was designed for the HVAC system. To improve the energy saving potential, the variable primary flow (VPF) sy...

Full description

Bibliographic Details
Main Authors: Yi-Zhi Lin, 林益誌
Other Authors: Fu-Jen Wang
Format: Others
Language:zh-TW
Published: 2016
Online Access:http://ndltd.ncl.edu.tw/handle/ar94e3
id ndltd-TW-104NCIT5680007
record_format oai_dc
spelling ndltd-TW-104NCIT56800072019-05-15T23:09:29Z http://ndltd.ncl.edu.tw/handle/ar94e3 面板廠房空調冰水系統使用一次側變流量之節能分析 面板廠房空調冰水系統使用一次側變流量之節能分析 Yi-Zhi Lin 林益誌 碩士 國立勤益科技大學 冷凍空調系 104 This study investigates the energy-saving strategy of chiller water system for cleanrooms in a TFT-LCD fab. A Primary-Secondary(P-S) Chiller Water System was designed for the HVAC system. To improve the energy saving potential, the variable primary flow (VPF) system were applied. Energy-Saving analysis was conducted by VPF system associated with HVAC system cooling load management. The results from field test measurement reveal that substantial energy-saving of 4.1 to 8.9% can be obtained through cooling load management, while the energy-saving of 2.4 to 6.1% can be achieved through VPF system. It is quite suitable for the 24 hour year round operation TFT-LCD fab specific for substantial energy-saving potential. Fu-Jen Wang 王輔仁 2016 學位論文 ; thesis 60 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立勤益科技大學 === 冷凍空調系 === 104 === This study investigates the energy-saving strategy of chiller water system for cleanrooms in a TFT-LCD fab. A Primary-Secondary(P-S) Chiller Water System was designed for the HVAC system. To improve the energy saving potential, the variable primary flow (VPF) system were applied. Energy-Saving analysis was conducted by VPF system associated with HVAC system cooling load management. The results from field test measurement reveal that substantial energy-saving of 4.1 to 8.9% can be obtained through cooling load management, while the energy-saving of 2.4 to 6.1% can be achieved through VPF system. It is quite suitable for the 24 hour year round operation TFT-LCD fab specific for substantial energy-saving potential.
author2 Fu-Jen Wang
author_facet Fu-Jen Wang
Yi-Zhi Lin
林益誌
author Yi-Zhi Lin
林益誌
spellingShingle Yi-Zhi Lin
林益誌
面板廠房空調冰水系統使用一次側變流量之節能分析
author_sort Yi-Zhi Lin
title 面板廠房空調冰水系統使用一次側變流量之節能分析
title_short 面板廠房空調冰水系統使用一次側變流量之節能分析
title_full 面板廠房空調冰水系統使用一次側變流量之節能分析
title_fullStr 面板廠房空調冰水系統使用一次側變流量之節能分析
title_full_unstemmed 面板廠房空調冰水系統使用一次側變流量之節能分析
title_sort 面板廠房空調冰水系統使用一次側變流量之節能分析
publishDate 2016
url http://ndltd.ncl.edu.tw/handle/ar94e3
work_keys_str_mv AT yizhilin miànbǎnchǎngfángkōngdiàobīngshuǐxìtǒngshǐyòngyīcìcèbiànliúliàngzhījiénéngfēnxī
AT línyìzhì miànbǎnchǎngfángkōngdiàobīngshuǐxìtǒngshǐyòngyīcìcèbiànliúliàngzhījiénéngfēnxī
_version_ 1719142082301394944