Power Factor Control of Permanent Magnet SynchronousWind Generator

碩士 === 明新科技大學 === 電機工程系碩士班 === 104 === This thesis proposed a novel power factor controller for vertical axis small wind generator. Unlike traditional power factor control method, which uses rotor field-oriented vector control, the control variable is tranformed from the stationary coordinate to syn...

Full description

Bibliographic Details
Main Authors: LIN,PO-YU, 林博裕
Other Authors: Ming-Fa Tsai
Format: Others
Language:zh-TW
Published: 2016
Online Access:http://ndltd.ncl.edu.tw/handle/60765905477605859681
id ndltd-TW-104MHIT0999003
record_format oai_dc
spelling ndltd-TW-104MHIT09990032017-10-15T04:37:06Z http://ndltd.ncl.edu.tw/handle/60765905477605859681 Power Factor Control of Permanent Magnet SynchronousWind Generator 永磁同步風力發電機之功率因數控制 LIN,PO-YU 林博裕 碩士 明新科技大學 電機工程系碩士班 104 This thesis proposed a novel power factor controller for vertical axis small wind generator. Unlike traditional power factor control method, which uses rotor field-oriented vector control, the control variable is tranformed from the stationary coordinate to synchronous rotation coordinate. By using the synchronously rotating coordinate to design PI controller, the three-phase output phase voltage and current signals of wind turbines can be the same phase. This can increase the efficiency of the wind turbine's output power. First, by using the PLL scheme, we capture the wind generator line voltage angle. Then the phase angle of the phase voltage can be obtained and based on which the current control output signal is calculated in the stationary coordinate. Next, a TMS320 F28335 digital signal processor is used to read the voltage and current signals. After PFC digital control, the wind turbine output current and the voltage can have the same phase. This method does not require the rotor position sensor and therefore cost can be reduced. This method advantage is no rotor position sensor in order to reduce costs. In this thesis, the simulation uses PSIM and a 300W (DS-300) vertical axis wind turbine. The system control core used DSP TMS320 F28335 digital signal processor as, and uses C programming language written. A 300W (DS-300) vertical axis wind turbine is the test subjects to verify the correctness of the closed-loop digital system. In order to verify the feasibility of this system, we used a TECO inverter SPEECON 7200MA to simulate the real environment under different wind speed. Key words: wind generators, PFC Control, phase-locked loop (PLL), PI controller. Ming-Fa Tsai 蔡明發 2016 學位論文 ; thesis 63 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 明新科技大學 === 電機工程系碩士班 === 104 === This thesis proposed a novel power factor controller for vertical axis small wind generator. Unlike traditional power factor control method, which uses rotor field-oriented vector control, the control variable is tranformed from the stationary coordinate to synchronous rotation coordinate. By using the synchronously rotating coordinate to design PI controller, the three-phase output phase voltage and current signals of wind turbines can be the same phase. This can increase the efficiency of the wind turbine's output power. First, by using the PLL scheme, we capture the wind generator line voltage angle. Then the phase angle of the phase voltage can be obtained and based on which the current control output signal is calculated in the stationary coordinate. Next, a TMS320 F28335 digital signal processor is used to read the voltage and current signals. After PFC digital control, the wind turbine output current and the voltage can have the same phase. This method does not require the rotor position sensor and therefore cost can be reduced. This method advantage is no rotor position sensor in order to reduce costs. In this thesis, the simulation uses PSIM and a 300W (DS-300) vertical axis wind turbine. The system control core used DSP TMS320 F28335 digital signal processor as, and uses C programming language written. A 300W (DS-300) vertical axis wind turbine is the test subjects to verify the correctness of the closed-loop digital system. In order to verify the feasibility of this system, we used a TECO inverter SPEECON 7200MA to simulate the real environment under different wind speed. Key words: wind generators, PFC Control, phase-locked loop (PLL), PI controller.
author2 Ming-Fa Tsai
author_facet Ming-Fa Tsai
LIN,PO-YU
林博裕
author LIN,PO-YU
林博裕
spellingShingle LIN,PO-YU
林博裕
Power Factor Control of Permanent Magnet SynchronousWind Generator
author_sort LIN,PO-YU
title Power Factor Control of Permanent Magnet SynchronousWind Generator
title_short Power Factor Control of Permanent Magnet SynchronousWind Generator
title_full Power Factor Control of Permanent Magnet SynchronousWind Generator
title_fullStr Power Factor Control of Permanent Magnet SynchronousWind Generator
title_full_unstemmed Power Factor Control of Permanent Magnet SynchronousWind Generator
title_sort power factor control of permanent magnet synchronouswind generator
publishDate 2016
url http://ndltd.ncl.edu.tw/handle/60765905477605859681
work_keys_str_mv AT linpoyu powerfactorcontrolofpermanentmagnetsynchronouswindgenerator
AT línbóyù powerfactorcontrolofpermanentmagnetsynchronouswindgenerator
AT linpoyu yǒngcítóngbùfēnglìfādiànjīzhīgōnglǜyīnshùkòngzhì
AT línbóyù yǒngcítóngbùfēnglìfādiànjīzhīgōnglǜyīnshùkòngzhì
_version_ 1718555064694472704