A study on the effect of river revetment on soil absorption and water flow
碩士 === 國立高雄應用科技大學 === 土木工程與防災科技研究所 === 104 === According to the result of this research,it will be certain that spreading failure which caused by absorbent or water immersion is not going to happen on filling embankments project,just if the energy provides following the ASTM D698 standard compact...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
2016
|
Online Access: | http://ndltd.ncl.edu.tw/handle/39246684020924476169 |
id |
ndltd-TW-104KUAS0653042 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-104KUAS06530422016-12-22T04:19:20Z http://ndltd.ncl.edu.tw/handle/39246684020924476169 A study on the effect of river revetment on soil absorption and water flow 河川護岸之夯實土壤吸水流潰行為研究 Chen,Yen-Chang 陳彥璋 碩士 國立高雄應用科技大學 土木工程與防災科技研究所 104 According to the result of this research,it will be certain that spreading failure which caused by absorbent or water immersion is not going to happen on filling embankments project,just if the energy provides following the ASTM D698 standard compactions norm. This paper is discussing about the relationship of embankment which between moisture content and spreading failure after water immersion with different thickness compaction but same energy effect. To observed the spreading failure which caused by self absorbent,we decide to make a hydraulic model,size:88.5cm×88.5cm×500cm with different thickness to be compact but same energy effect,after finish,put 400cm high water behind embankment until model been spreading failure, to obtain: 1.When the embankment been destroyed,then,measure the value for spreading angle and spread moisture,to compare the value,we make Atterberg flow limit test、maximum static friction angle for spreading test and moisture test ether,we can find that the value of test are as same as model failure. 2.We took a small part to make a soaking swelling test,it shows that the energy provides each ft^3 from model 10cm compact each high is higher then ASTM D698 standers require,which means its not able to happened spreading failure. 3.Compacted soil moisture after flooding changes are more than the plastic limit (PL), all occurred in the hydraulic model test water downstream slope perforation spreading destroyed. According to those tests,to prevent preading failure,we suggest to use less than 10cm compact for each high to filling embankment and all energy provides needs to be comform or more than ASTM D698 standers require norm,last,the value of swelling test can not over than liquid limit. Sheen Mau-Song 沈茂松 2016 學位論文 ; thesis 97 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 國立高雄應用科技大學 === 土木工程與防災科技研究所 === 104 === According to the result of this research,it will be certain that spreading failure which caused by absorbent or water immersion is not going to happen on filling embankments project,just if the energy provides following the ASTM D698 standard compactions norm.
This paper is discussing about the relationship of embankment which between moisture content and spreading failure after water immersion with different thickness compaction but same energy effect.
To observed the spreading failure which caused by self absorbent,we decide to make a hydraulic model,size:88.5cm×88.5cm×500cm with different thickness to be compact but same energy effect,after finish,put 400cm high water behind embankment until model been spreading failure, to obtain:
1.When the embankment been destroyed,then,measure the value for spreading angle and spread moisture,to compare the value,we make Atterberg flow limit test、maximum static friction angle for spreading test and moisture test ether,we can find that the value of test are as same as model failure.
2.We took a small part to make a soaking swelling test,it shows that the energy provides each ft^3 from model 10cm compact each high is higher then ASTM D698 standers require,which means its not able to happened spreading failure.
3.Compacted soil moisture after flooding changes are more than the plastic limit (PL), all occurred in the hydraulic model test water downstream slope perforation spreading destroyed.
According to those tests,to prevent preading failure,we suggest to use less than 10cm compact for each high to filling embankment and all energy provides needs to be comform or more than ASTM D698 standers require norm,last,the value of swelling test can not over than liquid limit.
|
author2 |
Sheen Mau-Song |
author_facet |
Sheen Mau-Song Chen,Yen-Chang 陳彥璋 |
author |
Chen,Yen-Chang 陳彥璋 |
spellingShingle |
Chen,Yen-Chang 陳彥璋 A study on the effect of river revetment on soil absorption and water flow |
author_sort |
Chen,Yen-Chang |
title |
A study on the effect of river revetment on soil absorption and water flow |
title_short |
A study on the effect of river revetment on soil absorption and water flow |
title_full |
A study on the effect of river revetment on soil absorption and water flow |
title_fullStr |
A study on the effect of river revetment on soil absorption and water flow |
title_full_unstemmed |
A study on the effect of river revetment on soil absorption and water flow |
title_sort |
study on the effect of river revetment on soil absorption and water flow |
publishDate |
2016 |
url |
http://ndltd.ncl.edu.tw/handle/39246684020924476169 |
work_keys_str_mv |
AT chenyenchang astudyontheeffectofriverrevetmentonsoilabsorptionandwaterflow AT chényànzhāng astudyontheeffectofriverrevetmentonsoilabsorptionandwaterflow AT chenyenchang héchuānhùànzhīhāngshítǔrǎngxīshuǐliúkuìxíngwèiyánjiū AT chényànzhāng héchuānhùànzhīhāngshítǔrǎngxīshuǐliúkuìxíngwèiyánjiū AT chenyenchang studyontheeffectofriverrevetmentonsoilabsorptionandwaterflow AT chényànzhāng studyontheeffectofriverrevetmentonsoilabsorptionandwaterflow |
_version_ |
1718405416481718272 |