碩士 === 國立高雄應用科技大學 === 電機工程系博碩士班 === 104 === The thesis is a study on parameter measurement of induction motor by using LabVIEW. With the DAQ card PCI-6024E from the National Instruments accompanied with the external circuitry, LabVIEW is able to read and save the values of the motor voltage, current...

Full description

Bibliographic Details
Main Authors: SYU,JHIH-MING, 許志銘
Other Authors: WU,HONG-YUAN
Format: Others
Language:zh-TW
Published: 2016
Online Access:http://ndltd.ncl.edu.tw/handle/55520429492589468751
id ndltd-TW-104KUAS0442009
record_format oai_dc
spelling ndltd-TW-104KUAS04420092017-04-08T04:31:37Z http://ndltd.ncl.edu.tw/handle/55520429492589468751 Study of Induction Motor Parameter Measurement by Using LabVIEW 使用LabVIEW作為馬達參數量測之研究 SYU,JHIH-MING 許志銘 碩士 國立高雄應用科技大學 電機工程系博碩士班 104 The thesis is a study on parameter measurement of induction motor by using LabVIEW. With the DAQ card PCI-6024E from the National Instruments accompanied with the external circuitry, LabVIEW is able to read and save the values of the motor voltage, current and revolutions. Then, the study use MATLAB to analyze the data. By running the no-load test and the blocked-rotor test, the study can get the motor’s parameters. With the LabVIEW, the study can control the motor’s operating time and set the minimum running time for 0.1 second. Therefore, the study can run the full-voltage blocked-rotor test and get the values of voltage and current at a high speed to calculate the instantaneous power without damaging the motor. Therefore, we could have a more accurate S-T curve than running low-voltage blocked-rotor test. The experiments and tests prove its accuracy. WU,HONG-YUAN 吳鴻源 2016 學位論文 ; thesis 66 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立高雄應用科技大學 === 電機工程系博碩士班 === 104 === The thesis is a study on parameter measurement of induction motor by using LabVIEW. With the DAQ card PCI-6024E from the National Instruments accompanied with the external circuitry, LabVIEW is able to read and save the values of the motor voltage, current and revolutions. Then, the study use MATLAB to analyze the data. By running the no-load test and the blocked-rotor test, the study can get the motor’s parameters. With the LabVIEW, the study can control the motor’s operating time and set the minimum running time for 0.1 second. Therefore, the study can run the full-voltage blocked-rotor test and get the values of voltage and current at a high speed to calculate the instantaneous power without damaging the motor. Therefore, we could have a more accurate S-T curve than running low-voltage blocked-rotor test. The experiments and tests prove its accuracy.
author2 WU,HONG-YUAN
author_facet WU,HONG-YUAN
SYU,JHIH-MING
許志銘
author SYU,JHIH-MING
許志銘
spellingShingle SYU,JHIH-MING
許志銘
Study of Induction Motor Parameter Measurement by Using LabVIEW
author_sort SYU,JHIH-MING
title Study of Induction Motor Parameter Measurement by Using LabVIEW
title_short Study of Induction Motor Parameter Measurement by Using LabVIEW
title_full Study of Induction Motor Parameter Measurement by Using LabVIEW
title_fullStr Study of Induction Motor Parameter Measurement by Using LabVIEW
title_full_unstemmed Study of Induction Motor Parameter Measurement by Using LabVIEW
title_sort study of induction motor parameter measurement by using labview
publishDate 2016
url http://ndltd.ncl.edu.tw/handle/55520429492589468751
work_keys_str_mv AT syujhihming studyofinductionmotorparametermeasurementbyusinglabview
AT xǔzhìmíng studyofinductionmotorparametermeasurementbyusinglabview
AT syujhihming shǐyònglabviewzuòwèimǎdácānshùliàngcèzhīyánjiū
AT xǔzhìmíng shǐyònglabviewzuòwèimǎdácānshùliàngcèzhīyánjiū
_version_ 1718437183554060288