Study of Anodized Titania Nanotubes Applied to Homocysteine Measurement and Impedance Analysis
碩士 === 華梵大學 === 電子工程學系碩士班 === 104 === Cardiovascular diseases have been arranged in the forefront of the cause of dead of people, and Homocysteine is an independent risk factor for cardiovascular disease. So, it will be a great boon if development of low cost, high efficiency homocysteine biosensors...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
2016
|
Online Access: | http://ndltd.ncl.edu.tw/handle/42317664386953525758 |
id |
ndltd-TW-104HCHT0428014 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-104HCHT04280142017-11-12T04:38:47Z http://ndltd.ncl.edu.tw/handle/42317664386953525758 Study of Anodized Titania Nanotubes Applied to Homocysteine Measurement and Impedance Analysis 以陽極處理二氧化鈦奈米管感測器應用於高半胱胺酸量測和阻抗分析 Hsu,Feng-Ching 許峯菁 碩士 華梵大學 電子工程學系碩士班 104 Cardiovascular diseases have been arranged in the forefront of the cause of dead of people, and Homocysteine is an independent risk factor for cardiovascular disease. So, it will be a great boon if development of low cost, high efficiency homocysteine biosensors. In this thesis, titanium oxide nanotubes were fabricated by electrochemical anodized technique and used as the electrodes to test homocysteine. The growth of titania nanotubes used various electrolyte compositions and growth temperatures. The test of homocysteine reaction included cyclic voltammetry and impedance analysis. Finally ZView software was used for analysis. The results showed that prepared TiO2 nanotubes when an electrolye composition was 92.08 wt% ethylene glycol, 0.55 wt%NH4F, 7.37 wt% DI water, anodizing voltages was kept at 30 V, and temperature was kept at 24 °C. The sensitivity of homocysteine measurement using cyclic voltammetry is 238 nA/μM and the corresponding linearity is 0.989 in the homocysteine concentration is between 10 uM and 60 uM. The Impedance analysis showed a very good results for real and imaginary parts, wherein the corresponding to the lowest point of the graphic impedance real and imaginary parts of the linearity up to 0.991 and 0.984, respectively. Finally, Zview software was used to simulate the circuits of homocysteine sensor. Lin,Jyh-Ling 林智玲 2016 學位論文 ; thesis 54 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 華梵大學 === 電子工程學系碩士班 === 104 === Cardiovascular diseases have been arranged in the forefront of the cause of dead of people, and Homocysteine is an independent risk factor for cardiovascular disease. So, it will be a great boon if development of low cost, high efficiency homocysteine biosensors. In this thesis, titanium oxide nanotubes were fabricated by electrochemical anodized technique and used as the electrodes to test homocysteine. The growth of titania nanotubes used various electrolyte compositions and growth temperatures. The test of homocysteine reaction included cyclic voltammetry and impedance analysis. Finally ZView software was used for analysis.
The results showed that prepared TiO2 nanotubes when an electrolye composition was 92.08 wt% ethylene glycol, 0.55 wt%NH4F, 7.37 wt% DI water, anodizing voltages was kept at 30 V, and temperature was kept at 24 °C. The sensitivity of homocysteine measurement using cyclic voltammetry is 238 nA/μM and the corresponding linearity is 0.989 in the homocysteine concentration is between 10 uM and 60 uM. The Impedance analysis showed a very good results for real and imaginary parts, wherein the corresponding to the lowest point of the graphic impedance real and imaginary parts of the linearity up to 0.991 and 0.984, respectively. Finally, Zview software was used to simulate the circuits of homocysteine sensor.
|
author2 |
Lin,Jyh-Ling |
author_facet |
Lin,Jyh-Ling Hsu,Feng-Ching 許峯菁 |
author |
Hsu,Feng-Ching 許峯菁 |
spellingShingle |
Hsu,Feng-Ching 許峯菁 Study of Anodized Titania Nanotubes Applied to Homocysteine Measurement and Impedance Analysis |
author_sort |
Hsu,Feng-Ching |
title |
Study of Anodized Titania Nanotubes Applied to Homocysteine Measurement and Impedance Analysis |
title_short |
Study of Anodized Titania Nanotubes Applied to Homocysteine Measurement and Impedance Analysis |
title_full |
Study of Anodized Titania Nanotubes Applied to Homocysteine Measurement and Impedance Analysis |
title_fullStr |
Study of Anodized Titania Nanotubes Applied to Homocysteine Measurement and Impedance Analysis |
title_full_unstemmed |
Study of Anodized Titania Nanotubes Applied to Homocysteine Measurement and Impedance Analysis |
title_sort |
study of anodized titania nanotubes applied to homocysteine measurement and impedance analysis |
publishDate |
2016 |
url |
http://ndltd.ncl.edu.tw/handle/42317664386953525758 |
work_keys_str_mv |
AT hsufengching studyofanodizedtitaniananotubesappliedtohomocysteinemeasurementandimpedanceanalysis AT xǔfēngjīng studyofanodizedtitaniananotubesappliedtohomocysteinemeasurementandimpedanceanalysis AT hsufengching yǐyángjíchùlǐèryǎnghuàtàinàimǐguǎngǎncèqìyīngyòngyúgāobànguāngànsuānliàngcèhézǔkàngfēnxī AT xǔfēngjīng yǐyángjíchùlǐèryǎnghuàtàinàimǐguǎngǎncèqìyīngyòngyúgāobànguāngànsuānliàngcèhézǔkàngfēnxī |
_version_ |
1718561154074148864 |