Detection of Escherichia coli in hot spring samples
碩士 === 元培醫事科技大學 === 食品科學研究所 === 103 === E. coli (Escherichia coli) bacteria as indicators of water quality monitoring, water quality of representation if there E.coli contamination. In this study, the use of membrane filtration (Membrane filter method) and changes in the metabolism of E. coli spec...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Online Access: | http://ndltd.ncl.edu.tw/handle/87571253140112218445 |
id |
ndltd-TW-103YUST5253010 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-103YUST52530102016-08-28T04:12:40Z http://ndltd.ncl.edu.tw/handle/87571253140112218445 Detection of Escherichia coli in hot spring samples 溫泉樣品大腸桿菌之檢測 Chun-Chung Chiu 邱俊忠 碩士 元培醫事科技大學 食品科學研究所 103 E. coli (Escherichia coli) bacteria as indicators of water quality monitoring, water quality of representation if there E.coli contamination. In this study, the use of membrane filtration (Membrane filter method) and changes in the metabolism of E. coli specific conductivity of chemical signals detected E. coli spring water. The results show that the detection range of 103~108 CFU / mL, R2 is 0.9868, repeated detection of 106 CFU / mL, with good reproducibility, with an average of 3.13 ± 0.30 hours with an electrochemical method using a membrane filtration method can be low sample was concentrated achieve rapid detection. Display, electrochemical method has the potential to develop into a fast and stable quality of E. coli testing. Ku-Shang Chang 張谷昇 學位論文 ; thesis 57 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 元培醫事科技大學 === 食品科學研究所 === 103 === E. coli (Escherichia coli) bacteria as indicators of water quality monitoring, water quality of representation if there E.coli contamination. In this study, the use of membrane filtration (Membrane filter method) and changes in the metabolism of E. coli specific conductivity of chemical signals detected E. coli spring water. The results show that the detection range of 103~108 CFU / mL, R2 is 0.9868, repeated detection of 106 CFU / mL, with good reproducibility, with an average of 3.13 ± 0.30 hours with an electrochemical method using a membrane filtration method can be low sample was concentrated achieve rapid detection. Display, electrochemical method has the potential to develop into a fast and stable quality of E. coli testing.
|
author2 |
Ku-Shang Chang |
author_facet |
Ku-Shang Chang Chun-Chung Chiu 邱俊忠 |
author |
Chun-Chung Chiu 邱俊忠 |
spellingShingle |
Chun-Chung Chiu 邱俊忠 Detection of Escherichia coli in hot spring samples |
author_sort |
Chun-Chung Chiu |
title |
Detection of Escherichia coli in hot spring samples |
title_short |
Detection of Escherichia coli in hot spring samples |
title_full |
Detection of Escherichia coli in hot spring samples |
title_fullStr |
Detection of Escherichia coli in hot spring samples |
title_full_unstemmed |
Detection of Escherichia coli in hot spring samples |
title_sort |
detection of escherichia coli in hot spring samples |
url |
http://ndltd.ncl.edu.tw/handle/87571253140112218445 |
work_keys_str_mv |
AT chunchungchiu detectionofescherichiacoliinhotspringsamples AT qiūjùnzhōng detectionofescherichiacoliinhotspringsamples AT chunchungchiu wēnquányàngpǐndàchánggǎnjūnzhījiǎncè AT qiūjùnzhōng wēnquányàngpǐndàchánggǎnjūnzhījiǎncè |
_version_ |
1718381106034638848 |