The role of fan-shaped complete block on Helical Tomotherapy for esophageal cancer: a phantom study

碩士 === 國立陽明大學 === 生物醫學影像暨放射科學系 === 103 === Radiation pneumonitis (RP) is a common complication for radiotherapy of esophageal cancer and is associated with the low dose irradiated lung volume. This study aims to reduce the mean lung dose (MLD) and the relative lung volume at 20 Gy (V20) and at low d...

Full description

Bibliographic Details
Main Authors: Chiu-Han Chang, 張秋涵
Other Authors: Tung-Hsin Wu
Format: Others
Language:zh-TW
Published: 2015
Online Access:http://ndltd.ncl.edu.tw/handle/66419247807595550727
id ndltd-TW-103YM005605005
record_format oai_dc
spelling ndltd-TW-103YM0056050052017-02-26T04:27:42Z http://ndltd.ncl.edu.tw/handle/66419247807595550727 The role of fan-shaped complete block on Helical Tomotherapy for esophageal cancer: a phantom study 螺旋斷層加速器應用於食道腫瘤放射治療計劃設計FSCB之假體研究 Chiu-Han Chang 張秋涵 碩士 國立陽明大學 生物醫學影像暨放射科學系 103 Radiation pneumonitis (RP) is a common complication for radiotherapy of esophageal cancer and is associated with the low dose irradiated lung volume. This study aims to reduce the mean lung dose (MLD) and the relative lung volume at 20 Gy (V20) and at low dose region using various designs of the fan-shaped complete block (FSCB) in helical tomotherapy. Hypothetical esophageal tumor was delineated on an anthropomorphic phantom. The FSCB was defined as the fan-shaped radiation restricted area located in both lungs. Seven treatment plans were performed with non-block design and FSCB with different fan angles, i.e., from 90° to 140° with increment of 10°. The homogeneous index, conformation number, MLD and the relative lung volume receiving more than 5, 10, 15 and 20 Gy (V5, V10, V15, V20) were determined for each treatment scheme. There was a substantial reduction in the mean lung dose, V5, V10, V15 and V20 when using different types of FSCB as compared to the non-block design. The reduction of V20, V15, V10 and V5 was 6.3%-8.6%, 16%-23%, 42%-57% and 42%-66% for FSCB 90˚-140˚, respectively. The use of FSCB in helical tomotherapy is a promising method to reduce the MLD, V20 and relative lung volume in low dose region, especially in V5 and V10 for esophageal cancer. More dose reduction was observed for FSCB design with larger fan angles. Tung-Hsin Wu 吳東信 2015 學位論文 ; thesis 44 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立陽明大學 === 生物醫學影像暨放射科學系 === 103 === Radiation pneumonitis (RP) is a common complication for radiotherapy of esophageal cancer and is associated with the low dose irradiated lung volume. This study aims to reduce the mean lung dose (MLD) and the relative lung volume at 20 Gy (V20) and at low dose region using various designs of the fan-shaped complete block (FSCB) in helical tomotherapy. Hypothetical esophageal tumor was delineated on an anthropomorphic phantom. The FSCB was defined as the fan-shaped radiation restricted area located in both lungs. Seven treatment plans were performed with non-block design and FSCB with different fan angles, i.e., from 90° to 140° with increment of 10°. The homogeneous index, conformation number, MLD and the relative lung volume receiving more than 5, 10, 15 and 20 Gy (V5, V10, V15, V20) were determined for each treatment scheme. There was a substantial reduction in the mean lung dose, V5, V10, V15 and V20 when using different types of FSCB as compared to the non-block design. The reduction of V20, V15, V10 and V5 was 6.3%-8.6%, 16%-23%, 42%-57% and 42%-66% for FSCB 90˚-140˚, respectively. The use of FSCB in helical tomotherapy is a promising method to reduce the MLD, V20 and relative lung volume in low dose region, especially in V5 and V10 for esophageal cancer. More dose reduction was observed for FSCB design with larger fan angles.
author2 Tung-Hsin Wu
author_facet Tung-Hsin Wu
Chiu-Han Chang
張秋涵
author Chiu-Han Chang
張秋涵
spellingShingle Chiu-Han Chang
張秋涵
The role of fan-shaped complete block on Helical Tomotherapy for esophageal cancer: a phantom study
author_sort Chiu-Han Chang
title The role of fan-shaped complete block on Helical Tomotherapy for esophageal cancer: a phantom study
title_short The role of fan-shaped complete block on Helical Tomotherapy for esophageal cancer: a phantom study
title_full The role of fan-shaped complete block on Helical Tomotherapy for esophageal cancer: a phantom study
title_fullStr The role of fan-shaped complete block on Helical Tomotherapy for esophageal cancer: a phantom study
title_full_unstemmed The role of fan-shaped complete block on Helical Tomotherapy for esophageal cancer: a phantom study
title_sort role of fan-shaped complete block on helical tomotherapy for esophageal cancer: a phantom study
publishDate 2015
url http://ndltd.ncl.edu.tw/handle/66419247807595550727
work_keys_str_mv AT chiuhanchang theroleoffanshapedcompleteblockonhelicaltomotherapyforesophagealcanceraphantomstudy
AT zhāngqiūhán theroleoffanshapedcompleteblockonhelicaltomotherapyforesophagealcanceraphantomstudy
AT chiuhanchang luóxuánduàncéngjiāsùqìyīngyòngyúshídàozhǒngliúfàngshèzhìliáojìhuàshèjìfscbzhījiǎtǐyánjiū
AT zhāngqiūhán luóxuánduàncéngjiāsùqìyīngyòngyúshídàozhǒngliúfàngshèzhìliáojìhuàshèjìfscbzhījiǎtǐyánjiū
AT chiuhanchang roleoffanshapedcompleteblockonhelicaltomotherapyforesophagealcanceraphantomstudy
AT zhāngqiūhán roleoffanshapedcompleteblockonhelicaltomotherapyforesophagealcanceraphantomstudy
_version_ 1718417074528714752