Membrane extraction in cross-flow multipass modules with modified correction-factor analysis

碩士 === 淡江大學 === 化學工程與材料工程學系碩士班 === 103 === The expressions of mass-transfer rate for membrane extraction through a cross-flow multipass membrane module have been derived based on the modified correction-factor analysis. These expressions, as well as the correction-factor charts modified, are explici...

Full description

Bibliographic Details
Main Authors: Yen-Heng Chen, 陳衍亨
Other Authors: 葉和明
Format: Others
Language:zh-TW
Published: 2015
Online Access:http://ndltd.ncl.edu.tw/handle/89054876754110688764
id ndltd-TW-103TKU05063009
record_format oai_dc
spelling ndltd-TW-103TKU050630092016-08-12T04:14:30Z http://ndltd.ncl.edu.tw/handle/89054876754110688764 Membrane extraction in cross-flow multipass modules with modified correction-factor analysis 交流型多行程萃取之改良型修正因子 Yen-Heng Chen 陳衍亨 碩士 淡江大學 化學工程與材料工程學系碩士班 103 The expressions of mass-transfer rate for membrane extraction through a cross-flow multipass membrane module have been derived based on the modified correction-factor analysis. These expressions, as well as the correction-factor charts modified, are explicit and the results can be readily calculated without using try-and-error method, which should be employed in the conventional correction-factor analysis for designing heat and mass exchangers. Experimental results confirm the predicted values for membrane extraction of acetic acid from aqueous solution by methyl isobutyl ketone in cross-flow multipass device. 葉和明 2015 學位論文 ; thesis 76 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 淡江大學 === 化學工程與材料工程學系碩士班 === 103 === The expressions of mass-transfer rate for membrane extraction through a cross-flow multipass membrane module have been derived based on the modified correction-factor analysis. These expressions, as well as the correction-factor charts modified, are explicit and the results can be readily calculated without using try-and-error method, which should be employed in the conventional correction-factor analysis for designing heat and mass exchangers. Experimental results confirm the predicted values for membrane extraction of acetic acid from aqueous solution by methyl isobutyl ketone in cross-flow multipass device.
author2 葉和明
author_facet 葉和明
Yen-Heng Chen
陳衍亨
author Yen-Heng Chen
陳衍亨
spellingShingle Yen-Heng Chen
陳衍亨
Membrane extraction in cross-flow multipass modules with modified correction-factor analysis
author_sort Yen-Heng Chen
title Membrane extraction in cross-flow multipass modules with modified correction-factor analysis
title_short Membrane extraction in cross-flow multipass modules with modified correction-factor analysis
title_full Membrane extraction in cross-flow multipass modules with modified correction-factor analysis
title_fullStr Membrane extraction in cross-flow multipass modules with modified correction-factor analysis
title_full_unstemmed Membrane extraction in cross-flow multipass modules with modified correction-factor analysis
title_sort membrane extraction in cross-flow multipass modules with modified correction-factor analysis
publishDate 2015
url http://ndltd.ncl.edu.tw/handle/89054876754110688764
work_keys_str_mv AT yenhengchen membraneextractionincrossflowmultipassmoduleswithmodifiedcorrectionfactoranalysis
AT chényǎnhēng membraneextractionincrossflowmultipassmoduleswithmodifiedcorrectionfactoranalysis
AT yenhengchen jiāoliúxíngduōxíngchéngcuìqǔzhīgǎiliángxíngxiūzhèngyīnzi
AT chényǎnhēng jiāoliúxíngduōxíngchéngcuìqǔzhīgǎiliángxíngxiūzhèngyīnzi
_version_ 1718374587564032000