Membrane extraction in cross-flow multipass modules with modified correction-factor analysis
碩士 === 淡江大學 === 化學工程與材料工程學系碩士班 === 103 === The expressions of mass-transfer rate for membrane extraction through a cross-flow multipass membrane module have been derived based on the modified correction-factor analysis. These expressions, as well as the correction-factor charts modified, are explici...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
2015
|
Online Access: | http://ndltd.ncl.edu.tw/handle/89054876754110688764 |
id |
ndltd-TW-103TKU05063009 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-103TKU050630092016-08-12T04:14:30Z http://ndltd.ncl.edu.tw/handle/89054876754110688764 Membrane extraction in cross-flow multipass modules with modified correction-factor analysis 交流型多行程萃取之改良型修正因子 Yen-Heng Chen 陳衍亨 碩士 淡江大學 化學工程與材料工程學系碩士班 103 The expressions of mass-transfer rate for membrane extraction through a cross-flow multipass membrane module have been derived based on the modified correction-factor analysis. These expressions, as well as the correction-factor charts modified, are explicit and the results can be readily calculated without using try-and-error method, which should be employed in the conventional correction-factor analysis for designing heat and mass exchangers. Experimental results confirm the predicted values for membrane extraction of acetic acid from aqueous solution by methyl isobutyl ketone in cross-flow multipass device. 葉和明 2015 學位論文 ; thesis 76 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 淡江大學 === 化學工程與材料工程學系碩士班 === 103 === The expressions of mass-transfer rate for membrane extraction through a cross-flow multipass membrane module have been derived based on the modified correction-factor analysis. These expressions, as well as the correction-factor charts modified, are explicit and the results can be readily calculated without using try-and-error method, which should be employed in the conventional correction-factor analysis for designing heat and mass exchangers. Experimental results confirm the predicted values for membrane extraction of acetic acid from aqueous solution by methyl isobutyl ketone in cross-flow multipass device.
|
author2 |
葉和明 |
author_facet |
葉和明 Yen-Heng Chen 陳衍亨 |
author |
Yen-Heng Chen 陳衍亨 |
spellingShingle |
Yen-Heng Chen 陳衍亨 Membrane extraction in cross-flow multipass modules with modified correction-factor analysis |
author_sort |
Yen-Heng Chen |
title |
Membrane extraction in cross-flow multipass modules with modified correction-factor analysis |
title_short |
Membrane extraction in cross-flow multipass modules with modified correction-factor analysis |
title_full |
Membrane extraction in cross-flow multipass modules with modified correction-factor analysis |
title_fullStr |
Membrane extraction in cross-flow multipass modules with modified correction-factor analysis |
title_full_unstemmed |
Membrane extraction in cross-flow multipass modules with modified correction-factor analysis |
title_sort |
membrane extraction in cross-flow multipass modules with modified correction-factor analysis |
publishDate |
2015 |
url |
http://ndltd.ncl.edu.tw/handle/89054876754110688764 |
work_keys_str_mv |
AT yenhengchen membraneextractionincrossflowmultipassmoduleswithmodifiedcorrectionfactoranalysis AT chényǎnhēng membraneextractionincrossflowmultipassmoduleswithmodifiedcorrectionfactoranalysis AT yenhengchen jiāoliúxíngduōxíngchéngcuìqǔzhīgǎiliángxíngxiūzhèngyīnzi AT chényǎnhēng jiāoliúxíngduōxíngchéngcuìqǔzhīgǎiliángxíngxiūzhèngyīnzi |
_version_ |
1718374587564032000 |