The Numerical Study on Evaluating the Safety of Refrigerant Leakage for a R290 Air-Conditioner

碩士 === 國立臺北科技大學 === 冷凍空調工程系所 === 103 === Refrigerant R290 possesses the characteristics of non-ozone layer depletion and low global warming potential (GWP). But, it belongs to the combustible refrigerant and it could cause a fire accident or explosion. This study used the numerical simulation to eva...

Full description

Bibliographic Details
Main Authors: Rih-Cheng Cheng, 程日城
Other Authors: Yang-Cheng Shih
Language:zh-TW
Online Access:http://ndltd.ncl.edu.tw/handle/u7a77h
id ndltd-TW-103TIT05703045
record_format oai_dc
spelling ndltd-TW-103TIT057030452019-07-17T03:54:21Z http://ndltd.ncl.edu.tw/handle/u7a77h The Numerical Study on Evaluating the Safety of Refrigerant Leakage for a R290 Air-Conditioner 以數值方法評估R290空調機冷媒洩漏安全之研究 Rih-Cheng Cheng 程日城 碩士 國立臺北科技大學 冷凍空調工程系所 103 Refrigerant R290 possesses the characteristics of non-ozone layer depletion and low global warming potential (GWP). But, it belongs to the combustible refrigerant and it could cause a fire accident or explosion. This study used the numerical simulation to evaluate the safety of refrigerant leakage for a R290 air-conditioner. The CFD package software, ANSYS FLUENT, was employed to simulate the diffusion process of the leaking refrigerant within an indoor. During the CFD simulation, two leakage positions were considered: one was set at the pipe connector joining the inside and outside units, and the other was set at the return tubes of evaporator inside the indoor unit. In addition, the on and off of the compressor and the exhaust fan were also considered as the operating conditions. Comparing the numerical results with those of the experiment in literature, it can be found that both results had similar trend on the concentration distribution of R290. The numerical results also show that it is beneficial to lower the indoor R290 concentration when the exhaust fan was turned on. Moreover, avoiding the occurrence of flow circulation can reduce the accumulation of R290, causing that the rise of R290 concentration. Yang-Cheng Shih 施陽正 學位論文 ; thesis zh-TW
collection NDLTD
language zh-TW
sources NDLTD
description 碩士 === 國立臺北科技大學 === 冷凍空調工程系所 === 103 === Refrigerant R290 possesses the characteristics of non-ozone layer depletion and low global warming potential (GWP). But, it belongs to the combustible refrigerant and it could cause a fire accident or explosion. This study used the numerical simulation to evaluate the safety of refrigerant leakage for a R290 air-conditioner. The CFD package software, ANSYS FLUENT, was employed to simulate the diffusion process of the leaking refrigerant within an indoor. During the CFD simulation, two leakage positions were considered: one was set at the pipe connector joining the inside and outside units, and the other was set at the return tubes of evaporator inside the indoor unit. In addition, the on and off of the compressor and the exhaust fan were also considered as the operating conditions. Comparing the numerical results with those of the experiment in literature, it can be found that both results had similar trend on the concentration distribution of R290. The numerical results also show that it is beneficial to lower the indoor R290 concentration when the exhaust fan was turned on. Moreover, avoiding the occurrence of flow circulation can reduce the accumulation of R290, causing that the rise of R290 concentration.
author2 Yang-Cheng Shih
author_facet Yang-Cheng Shih
Rih-Cheng Cheng
程日城
author Rih-Cheng Cheng
程日城
spellingShingle Rih-Cheng Cheng
程日城
The Numerical Study on Evaluating the Safety of Refrigerant Leakage for a R290 Air-Conditioner
author_sort Rih-Cheng Cheng
title The Numerical Study on Evaluating the Safety of Refrigerant Leakage for a R290 Air-Conditioner
title_short The Numerical Study on Evaluating the Safety of Refrigerant Leakage for a R290 Air-Conditioner
title_full The Numerical Study on Evaluating the Safety of Refrigerant Leakage for a R290 Air-Conditioner
title_fullStr The Numerical Study on Evaluating the Safety of Refrigerant Leakage for a R290 Air-Conditioner
title_full_unstemmed The Numerical Study on Evaluating the Safety of Refrigerant Leakage for a R290 Air-Conditioner
title_sort numerical study on evaluating the safety of refrigerant leakage for a r290 air-conditioner
url http://ndltd.ncl.edu.tw/handle/u7a77h
work_keys_str_mv AT rihchengcheng thenumericalstudyonevaluatingthesafetyofrefrigerantleakageforar290airconditioner
AT chéngrìchéng thenumericalstudyonevaluatingthesafetyofrefrigerantleakageforar290airconditioner
AT rihchengcheng yǐshùzhífāngfǎpínggūr290kōngdiàojīlěngméixièlòuānquánzhīyánjiū
AT chéngrìchéng yǐshùzhífāngfǎpínggūr290kōngdiàojīlěngméixièlòuānquánzhīyánjiū
AT rihchengcheng numericalstudyonevaluatingthesafetyofrefrigerantleakageforar290airconditioner
AT chéngrìchéng numericalstudyonevaluatingthesafetyofrefrigerantleakageforar290airconditioner
_version_ 1719224211880280064