Design and Fabrication of Heart Disease Biological Detection Chip Based On Reduced Graphene Oxide
碩士 === 國立臺北科技大學 === 機電整合研究所 === 103 === The fabrication of a highly sensitive reduced graphene oxide field-effect transistor (rGO-FET) for the detection of Troponin I has been investigated in this study. Due to the excellent mechanical property and conductivity, reduced graphene oxide was utilized o...
Main Authors: | , |
---|---|
Other Authors: | |
Language: | zh-TW |
Online Access: | http://ndltd.ncl.edu.tw/handle/46g7wq |
id |
ndltd-TW-103TIT05651051 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-103TIT056510512019-06-30T05:21:58Z http://ndltd.ncl.edu.tw/handle/46g7wq Design and Fabrication of Heart Disease Biological Detection Chip Based On Reduced Graphene Oxide 還原氧化石墨烯場效電晶體之心臟疾病生物感測晶片設計與製作 Huai wei hsieh 謝懷緯 碩士 國立臺北科技大學 機電整合研究所 103 The fabrication of a highly sensitive reduced graphene oxide field-effect transistor (rGO-FET) for the detection of Troponin I has been investigated in this study. Due to the excellent mechanical property and conductivity, reduced graphene oxide was utilized on rGO-FET through covalent binding. The interaction between aptamer and target Troponin I would generate a current signal in SMU measurement. The results demonstrate aptamer modified rGO-FET enables to detect Troponin I specifically and the detection limit was estimated to be 10 ng/c.c. Jung Tang Huang 林震 黃榮堂 學位論文 ; thesis zh-TW |
collection |
NDLTD |
language |
zh-TW |
sources |
NDLTD |
description |
碩士 === 國立臺北科技大學 === 機電整合研究所 === 103 === The fabrication of a highly sensitive reduced graphene oxide field-effect transistor (rGO-FET) for the detection of Troponin I has been investigated in this study. Due to the excellent mechanical property and conductivity, reduced graphene oxide was utilized on rGO-FET through covalent binding. The interaction between aptamer and target Troponin I would generate a current signal in SMU measurement. The results demonstrate aptamer modified rGO-FET enables to detect Troponin I specifically and the detection limit was estimated to be 10 ng/c.c.
|
author2 |
Jung Tang Huang |
author_facet |
Jung Tang Huang Huai wei hsieh 謝懷緯 |
author |
Huai wei hsieh 謝懷緯 |
spellingShingle |
Huai wei hsieh 謝懷緯 Design and Fabrication of Heart Disease Biological Detection Chip Based On Reduced Graphene Oxide |
author_sort |
Huai wei hsieh |
title |
Design and Fabrication of Heart Disease Biological Detection Chip Based On Reduced Graphene Oxide |
title_short |
Design and Fabrication of Heart Disease Biological Detection Chip Based On Reduced Graphene Oxide |
title_full |
Design and Fabrication of Heart Disease Biological Detection Chip Based On Reduced Graphene Oxide |
title_fullStr |
Design and Fabrication of Heart Disease Biological Detection Chip Based On Reduced Graphene Oxide |
title_full_unstemmed |
Design and Fabrication of Heart Disease Biological Detection Chip Based On Reduced Graphene Oxide |
title_sort |
design and fabrication of heart disease biological detection chip based on reduced graphene oxide |
url |
http://ndltd.ncl.edu.tw/handle/46g7wq |
work_keys_str_mv |
AT huaiweihsieh designandfabricationofheartdiseasebiologicaldetectionchipbasedonreducedgrapheneoxide AT xièhuáiwěi designandfabricationofheartdiseasebiologicaldetectionchipbasedonreducedgrapheneoxide AT huaiweihsieh háiyuányǎnghuàshímòxīchǎngxiàodiànjīngtǐzhīxīnzàngjíbìngshēngwùgǎncèjīngpiànshèjìyǔzhìzuò AT xièhuáiwěi háiyuányǎnghuàshímòxīchǎngxiàodiànjīngtǐzhīxīnzàngjíbìngshēngwùgǎncèjīngpiànshèjìyǔzhìzuò |
_version_ |
1719214408487403520 |