Design and Fabrication of Heart Disease Biological Detection Chip Based On Reduced Graphene Oxide

碩士 === 國立臺北科技大學 === 機電整合研究所 === 103 === The fabrication of a highly sensitive reduced graphene oxide field-effect transistor (rGO-FET) for the detection of Troponin I has been investigated in this study. Due to the excellent mechanical property and conductivity, reduced graphene oxide was utilized o...

Full description

Bibliographic Details
Main Authors: Huai wei hsieh, 謝懷緯
Other Authors: Jung Tang Huang
Language:zh-TW
Online Access:http://ndltd.ncl.edu.tw/handle/46g7wq
id ndltd-TW-103TIT05651051
record_format oai_dc
spelling ndltd-TW-103TIT056510512019-06-30T05:21:58Z http://ndltd.ncl.edu.tw/handle/46g7wq Design and Fabrication of Heart Disease Biological Detection Chip Based On Reduced Graphene Oxide 還原氧化石墨烯場效電晶體之心臟疾病生物感測晶片設計與製作 Huai wei hsieh 謝懷緯 碩士 國立臺北科技大學 機電整合研究所 103 The fabrication of a highly sensitive reduced graphene oxide field-effect transistor (rGO-FET) for the detection of Troponin I has been investigated in this study. Due to the excellent mechanical property and conductivity, reduced graphene oxide was utilized on rGO-FET through covalent binding. The interaction between aptamer and target Troponin I would generate a current signal in SMU measurement. The results demonstrate aptamer modified rGO-FET enables to detect Troponin I specifically and the detection limit was estimated to be 10 ng/c.c. Jung Tang Huang 林震 黃榮堂 學位論文 ; thesis zh-TW
collection NDLTD
language zh-TW
sources NDLTD
description 碩士 === 國立臺北科技大學 === 機電整合研究所 === 103 === The fabrication of a highly sensitive reduced graphene oxide field-effect transistor (rGO-FET) for the detection of Troponin I has been investigated in this study. Due to the excellent mechanical property and conductivity, reduced graphene oxide was utilized on rGO-FET through covalent binding. The interaction between aptamer and target Troponin I would generate a current signal in SMU measurement. The results demonstrate aptamer modified rGO-FET enables to detect Troponin I specifically and the detection limit was estimated to be 10 ng/c.c.
author2 Jung Tang Huang
author_facet Jung Tang Huang
Huai wei hsieh
謝懷緯
author Huai wei hsieh
謝懷緯
spellingShingle Huai wei hsieh
謝懷緯
Design and Fabrication of Heart Disease Biological Detection Chip Based On Reduced Graphene Oxide
author_sort Huai wei hsieh
title Design and Fabrication of Heart Disease Biological Detection Chip Based On Reduced Graphene Oxide
title_short Design and Fabrication of Heart Disease Biological Detection Chip Based On Reduced Graphene Oxide
title_full Design and Fabrication of Heart Disease Biological Detection Chip Based On Reduced Graphene Oxide
title_fullStr Design and Fabrication of Heart Disease Biological Detection Chip Based On Reduced Graphene Oxide
title_full_unstemmed Design and Fabrication of Heart Disease Biological Detection Chip Based On Reduced Graphene Oxide
title_sort design and fabrication of heart disease biological detection chip based on reduced graphene oxide
url http://ndltd.ncl.edu.tw/handle/46g7wq
work_keys_str_mv AT huaiweihsieh designandfabricationofheartdiseasebiologicaldetectionchipbasedonreducedgrapheneoxide
AT xièhuáiwěi designandfabricationofheartdiseasebiologicaldetectionchipbasedonreducedgrapheneoxide
AT huaiweihsieh háiyuányǎnghuàshímòxīchǎngxiàodiànjīngtǐzhīxīnzàngjíbìngshēngwùgǎncèjīngpiànshèjìyǔzhìzuò
AT xièhuáiwěi háiyuányǎnghuàshímòxīchǎngxiàodiànjīngtǐzhīxīnzàngjíbìngshēngwùgǎncèjīngpiànshèjìyǔzhìzuò
_version_ 1719214408487403520