Application of neutron radiography to visualization of two phase flows in narrow rectangular ducts

碩士 === 國立清華大學 === 核子工程與科學研究所 === 103 === The purpose of this study is to investigate measurement of two-phase flow by using a neutron radiography. This system is utilized to determine the flow regime and void fraction in narrow rectangular vertical and horizontal channels, gap widths 1mm and 5 mm wi...

Full description

Bibliographic Details
Main Authors: Hsiao, Yu-Hsun, 蕭鈺勳
Other Authors: Chen, Shao-Wen
Format: Others
Language:zh-TW
Published: 2015
Online Access:http://ndltd.ncl.edu.tw/handle/38839748865645671562
id ndltd-TW-103NTHU5265019
record_format oai_dc
spelling ndltd-TW-103NTHU52650192016-08-15T04:17:32Z http://ndltd.ncl.edu.tw/handle/38839748865645671562 Application of neutron radiography to visualization of two phase flows in narrow rectangular ducts 中子照相應用於小管徑矩形管之雙相流可視化研究 Hsiao, Yu-Hsun 蕭鈺勳 碩士 國立清華大學 核子工程與科學研究所 103 The purpose of this study is to investigate measurement of two-phase flow by using a neutron radiography. This system is utilized to determine the flow regime and void fraction in narrow rectangular vertical and horizontal channels, gap widths 1mm and 5 mm with widths of 60 mm. The channel is operated as a bubbly and slug flow state. Visualization of air-water two-phase flow in a metal channel was performed at exposure time 0.2 second for neutron radiography. The optical system is used to compare with neutron radiography method. Results confirm the qualities of these images are not good to observe and measure two-phase flow in neutron radiography. A process was established in this study in order to reduce the noise and calculate void fraction. Separation distance between the test section and the scintillator is 33 cm, this results in image distortion due to neutron scattering. Σ-scaling method was used for void fraction of two-phase flow. Exposure time is so long that the void fraction calculation for gap widths 5 mm is larger than predicted value. For gap widths 1mm of two-phase flow, the result of void fraction is smaller than predicted value. Due to surface tension, the drift velocity is almost 0 and bubble velocity is not faster than gap widths 5 mm. Results confirm the void fraction tends to increase as the gas velocity increases. In order to understand the difference between the result by Σ-scaling method and true vlaue, metallic thickness from 1 to 4 mm are put into 5 mm metallic duct, respectively. It is found that the measured error for water layer thickness of 4mm is minimum. The measured error for full water is greater because neutron flux is not well-distributed. Chen, Shao-Wen 陳紹文 2015 學位論文 ; thesis 72 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立清華大學 === 核子工程與科學研究所 === 103 === The purpose of this study is to investigate measurement of two-phase flow by using a neutron radiography. This system is utilized to determine the flow regime and void fraction in narrow rectangular vertical and horizontal channels, gap widths 1mm and 5 mm with widths of 60 mm. The channel is operated as a bubbly and slug flow state. Visualization of air-water two-phase flow in a metal channel was performed at exposure time 0.2 second for neutron radiography. The optical system is used to compare with neutron radiography method. Results confirm the qualities of these images are not good to observe and measure two-phase flow in neutron radiography. A process was established in this study in order to reduce the noise and calculate void fraction. Separation distance between the test section and the scintillator is 33 cm, this results in image distortion due to neutron scattering. Σ-scaling method was used for void fraction of two-phase flow. Exposure time is so long that the void fraction calculation for gap widths 5 mm is larger than predicted value. For gap widths 1mm of two-phase flow, the result of void fraction is smaller than predicted value. Due to surface tension, the drift velocity is almost 0 and bubble velocity is not faster than gap widths 5 mm. Results confirm the void fraction tends to increase as the gas velocity increases. In order to understand the difference between the result by Σ-scaling method and true vlaue, metallic thickness from 1 to 4 mm are put into 5 mm metallic duct, respectively. It is found that the measured error for water layer thickness of 4mm is minimum. The measured error for full water is greater because neutron flux is not well-distributed.
author2 Chen, Shao-Wen
author_facet Chen, Shao-Wen
Hsiao, Yu-Hsun
蕭鈺勳
author Hsiao, Yu-Hsun
蕭鈺勳
spellingShingle Hsiao, Yu-Hsun
蕭鈺勳
Application of neutron radiography to visualization of two phase flows in narrow rectangular ducts
author_sort Hsiao, Yu-Hsun
title Application of neutron radiography to visualization of two phase flows in narrow rectangular ducts
title_short Application of neutron radiography to visualization of two phase flows in narrow rectangular ducts
title_full Application of neutron radiography to visualization of two phase flows in narrow rectangular ducts
title_fullStr Application of neutron radiography to visualization of two phase flows in narrow rectangular ducts
title_full_unstemmed Application of neutron radiography to visualization of two phase flows in narrow rectangular ducts
title_sort application of neutron radiography to visualization of two phase flows in narrow rectangular ducts
publishDate 2015
url http://ndltd.ncl.edu.tw/handle/38839748865645671562
work_keys_str_mv AT hsiaoyuhsun applicationofneutronradiographytovisualizationoftwophaseflowsinnarrowrectangularducts
AT xiāoyùxūn applicationofneutronradiographytovisualizationoftwophaseflowsinnarrowrectangularducts
AT hsiaoyuhsun zhōngzizhàoxiāngyīngyòngyúxiǎoguǎnjìngjǔxíngguǎnzhīshuāngxiāngliúkěshìhuàyánjiū
AT xiāoyùxūn zhōngzizhàoxiāngyīngyòngyúxiǎoguǎnjìngjǔxíngguǎnzhīshuāngxiāngliúkěshìhuàyánjiū
_version_ 1718376167553105920