Effect of Using a Mixture of γ-APTES and Metal Oxide Nanoparticles as the Sensing Membrane for Polysilicon Wire on pH Sensing

碩士 === 國立暨南國際大學 === 電機工程學系 === 103 === Based on the finding of our research group that using a mixture of silicate nanoparticles and 3-Aminopropyltriethoxysilane (γ-APTES) as the sensing membrane can enhance the sensitivity of poly-silicon wire sensor, the purpose of this work is to investigate the...

Full description

Bibliographic Details
Main Authors: Zong-Xian Wu, 吳宗憲
Other Authors: You-Lin Wu
Format: Others
Language:zh-TW
Published: 2015
Online Access:http://ndltd.ncl.edu.tw/handle/5x4s52
id ndltd-TW-103NCNU0442052
record_format oai_dc
spelling ndltd-TW-103NCNU04420522019-05-15T22:07:30Z http://ndltd.ncl.edu.tw/handle/5x4s52 Effect of Using a Mixture of γ-APTES and Metal Oxide Nanoparticles as the Sensing Membrane for Polysilicon Wire on pH Sensing 使用γ-APTES與金屬氧化物奈米粒混合物為感測層對多晶矽線於pH感測之效應 Zong-Xian Wu 吳宗憲 碩士 國立暨南國際大學 電機工程學系 103 Based on the finding of our research group that using a mixture of silicate nanoparticles and 3-Aminopropyltriethoxysilane (γ-APTES) as the sensing membrane can enhance the sensitivity of poly-silicon wire sensor, the purpose of this work is to investigate the feasibility of using mixtures of metal oxide nanoparticles and γ-APTES (3-Aminopropyltriethoxysilane) as the sensing membrane for poly-silicon wire and apply it for pH sensing. Solution phase deposition (SPD) method was adopted to deposit the individual mixture onto the PSW surface. Various ratios of dispersant/γ-APTES and nanoparticles/γ-APTES as well as different dispersants were tested when prepared the mixtures. The purpose of adding dispersant in the suspension of nanoparticles is to separate and avoid the conglomeration of nanoparticles. Dispersant for the best performance of PSW pH sensor as well as the optimum dispersant/γ-APTES ratio and nanoparticles/γ-APTES ratio for highest sensitivity of the PSW pH sensor were determined. Two different metal oxide nanoparticles, Al2O3 and TiO2, were used in this work. Dispersant 2566, 2760 for Al2O3 nanoparticles, and 1186, 1142, 2145 for TiO2 nanoparticles were tested in this work, all of which were purchased directly from the Marvel Chemical, Taiwan. From the experimental results, best pH sensing performance performance of the poly-silicon wire sensor can be obtained when the dispersant 2566 is used for Al2O3 and γ-APTES mixture, and 1186 for TiO2 and γ-APTES mixture. For Al2O3, it is found that a SPD deposition time of 5 min gives the highest PSW channel current, and a dispersant/γ-APTES ratio of 0.3% and nanoparticles/γ-APTES ratio of 2% is the best for PSW pH sensor performance. For TiO2, the best performance of the PSW pH sensor is found at a SPD deposition time of 10 min and with a dispersant/γ-APTES ratio of 0.3% and nanoparticles/γ-APTES ratio of 0.5%. Among other nanoparticles, it is found that the using the mixture of Al2O3 nanoparticles and γ-APTES as the sensing membrane has the best sensitivity. Our result also confirms that dispersant is absolutely necessary for preparing the nanoparticles suspension. You-Lin Wu 吳幼麟 2015 學位論文 ; thesis 68 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立暨南國際大學 === 電機工程學系 === 103 === Based on the finding of our research group that using a mixture of silicate nanoparticles and 3-Aminopropyltriethoxysilane (γ-APTES) as the sensing membrane can enhance the sensitivity of poly-silicon wire sensor, the purpose of this work is to investigate the feasibility of using mixtures of metal oxide nanoparticles and γ-APTES (3-Aminopropyltriethoxysilane) as the sensing membrane for poly-silicon wire and apply it for pH sensing. Solution phase deposition (SPD) method was adopted to deposit the individual mixture onto the PSW surface. Various ratios of dispersant/γ-APTES and nanoparticles/γ-APTES as well as different dispersants were tested when prepared the mixtures. The purpose of adding dispersant in the suspension of nanoparticles is to separate and avoid the conglomeration of nanoparticles. Dispersant for the best performance of PSW pH sensor as well as the optimum dispersant/γ-APTES ratio and nanoparticles/γ-APTES ratio for highest sensitivity of the PSW pH sensor were determined. Two different metal oxide nanoparticles, Al2O3 and TiO2, were used in this work. Dispersant 2566, 2760 for Al2O3 nanoparticles, and 1186, 1142, 2145 for TiO2 nanoparticles were tested in this work, all of which were purchased directly from the Marvel Chemical, Taiwan. From the experimental results, best pH sensing performance performance of the poly-silicon wire sensor can be obtained when the dispersant 2566 is used for Al2O3 and γ-APTES mixture, and 1186 for TiO2 and γ-APTES mixture. For Al2O3, it is found that a SPD deposition time of 5 min gives the highest PSW channel current, and a dispersant/γ-APTES ratio of 0.3% and nanoparticles/γ-APTES ratio of 2% is the best for PSW pH sensor performance. For TiO2, the best performance of the PSW pH sensor is found at a SPD deposition time of 10 min and with a dispersant/γ-APTES ratio of 0.3% and nanoparticles/γ-APTES ratio of 0.5%. Among other nanoparticles, it is found that the using the mixture of Al2O3 nanoparticles and γ-APTES as the sensing membrane has the best sensitivity. Our result also confirms that dispersant is absolutely necessary for preparing the nanoparticles suspension.
author2 You-Lin Wu
author_facet You-Lin Wu
Zong-Xian Wu
吳宗憲
author Zong-Xian Wu
吳宗憲
spellingShingle Zong-Xian Wu
吳宗憲
Effect of Using a Mixture of γ-APTES and Metal Oxide Nanoparticles as the Sensing Membrane for Polysilicon Wire on pH Sensing
author_sort Zong-Xian Wu
title Effect of Using a Mixture of γ-APTES and Metal Oxide Nanoparticles as the Sensing Membrane for Polysilicon Wire on pH Sensing
title_short Effect of Using a Mixture of γ-APTES and Metal Oxide Nanoparticles as the Sensing Membrane for Polysilicon Wire on pH Sensing
title_full Effect of Using a Mixture of γ-APTES and Metal Oxide Nanoparticles as the Sensing Membrane for Polysilicon Wire on pH Sensing
title_fullStr Effect of Using a Mixture of γ-APTES and Metal Oxide Nanoparticles as the Sensing Membrane for Polysilicon Wire on pH Sensing
title_full_unstemmed Effect of Using a Mixture of γ-APTES and Metal Oxide Nanoparticles as the Sensing Membrane for Polysilicon Wire on pH Sensing
title_sort effect of using a mixture of γ-aptes and metal oxide nanoparticles as the sensing membrane for polysilicon wire on ph sensing
publishDate 2015
url http://ndltd.ncl.edu.tw/handle/5x4s52
work_keys_str_mv AT zongxianwu effectofusingamixtureofgaptesandmetaloxidenanoparticlesasthesensingmembraneforpolysiliconwireonphsensing
AT wúzōngxiàn effectofusingamixtureofgaptesandmetaloxidenanoparticlesasthesensingmembraneforpolysiliconwireonphsensing
AT zongxianwu shǐyònggaptesyǔjīnshǔyǎnghuàwùnàimǐlìhùnhéwùwèigǎncècéngduìduōjīngxìxiànyúphgǎncèzhīxiàoyīng
AT wúzōngxiàn shǐyònggaptesyǔjīnshǔyǎnghuàwùnàimǐlìhùnhéwùwèigǎncècéngduìduōjīngxìxiànyúphgǎncèzhīxiàoyīng
_version_ 1719125062301253632